Elation Rayzor Q12 Zoom User Manual

RAYZOR Q12 ZOOM™
user manual! !
|
RAYZOR Q12 ZOOM
|
user manual
www.elationlighting.com
2 RAYZOR Q12 ZOOM™ User Manual ver 1
©2014 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
DOCUMENT VERSION
Please check www.elationlighting.com for the latest revision/update of this manual.
Date
Document
Version
Software
Version
DMX
Channel Modes
Notes
7/2014
1
1.0.0
17 / 20 / 28
Initial release.
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com
www.elationlighting.com
3 RAYZOR Q12 ZOOM™ User Manual ver 1
CONTENTS
General Information
4
Warranty
6
Safety Instructions
7
General Guidelines
8
Fixture Overview
9
Fixture Installation
10
Understanding DMX
13
Fixture Menu
17
DMX Channel Functions And Values
27
LED Groups
30
Error Codes
31
Cleaning and Maintenance
32
Technical Specifications
33
Optional Accessories
36
www.elationlighting.com
4 RAYZOR Q12 ZOOM™ User Manual ver 1
GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and
reliable lighting fixtures on the market today! The RAYZOR Q12 ZOOM™ has been
designed to perform reliably for years when the guidelines in this booklet are
followed. Please read and understand the instructions in this manual carefully
and thoroughly before attempting to operate this unit. These instructions contain
important information regarding safety during use and maintenance.
UNPACKING
Thank you for purchasing the RAYZOR Q12 ZOOM™ by Elation Professional®. Every
RAYZOR Q12 ZOOM™ has been thoroughly tested and has been shipped in
perfect operating condition. Carefully check the shipping carton for damage
that may have occurred during shipping. If the carton appears to be damaged,
carefully inspect your unit for damage and be sure all accessories necessary to
operate the unit have arrived intact. In the event damage has been found or
parts are missing, please contact our customer support team for further
instructions. Please do not return this unit to your dealer without first contacting
customer support at the number listed below. Please do not discard the shipping
carton in the trash. Please recycle whenever possible.
BOX CONTENTS
(2) Omega Brackets
(1) 5pin DMX Cable
(1) powerCON Cable
(1) Safety Cable
Manual & Warranty Card
www.elationlighting.com
5 RAYZOR Q12 ZOOM™ User Manual ver 1
CUSTOMER SUPPORT
Elation Professional® provides a customer support line, to provide set up help and
to answer any question should you encounter problems during your set up or
initial operation. You may also visit us on the web at www.elationlighting.com for
any comments or suggestions. For service related issue please contact Elation
Professional®.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
WARRANTY REGISTRATION
The RAYZOR Q12 ZOOM™ carries a two-year (730 days) limited warranty. Please fill
out the enclosed warranty card to validate your purchase. All returned service
items whether under warranty or not, must be freight pre-paid and accompany
a return authorization (R.A.) number. The R.A. number must be clearly written on
the outside of the return package. A brief description of the problem as well as
the R.A. number must also be written down on a piece of paper and included in
the shipping container. If the unit is under warranty, you must provide a copy of
your proof of purchase invoice. Items returned without a R.A. number clearly
marked on the outside of the package will be refused and returned at
customer’s expense. You may obtain a R.A. number by contacting customer
support at 323-582-3322.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are
not subject to any warranty claims and/or repairs.
www.elationlighting.com
6 RAYZOR Q12 ZOOM™ User Manual ver 1
2 - YEAR LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to
be free of manufacturing defects in material and workmanship for a period of two years, (730 days)
from the date of purchase. This warranty shall be valid only if the product is purchased within the
United States of America, including possessions and territories. It is the owner’s responsibility to
establish the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service, send the product only to the Elation Professional® factory. All shipping
charges must be pre-paid. If the requested repairs or service (including parts replacement) are within
the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated
point within the United States. If the entire instrument is sent, it must be shipped in its original package.
No accessories should be shipped with the product. If any accessories are shipped with the product,
Elation Professional® shall have no liability what so ever for loss of or damage to any such accessories,
nor for the safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the product is modified
in any manner which Elation Professional® concludes, after inspection, affects the reliability of the
product; if the product has been repaired or serviced by anyone other than the Elation Professional®
factory unless prior written authorization was issued to purchaser by Elation Professional®; if the
product is damaged because not properly maintained as set forth in the instruction manual.
D. This is not a service contract, and this warranty does not include maintenance, cleaning or
periodic check-up. During the period specified above, Elation Professional® will replace defective
parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of
defects in material or workmanship. The sole responsibility of Elation Professional® under this
warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the
sole discretion of Elation Professional®. All products covered by this warranty were manufactured
after January 1, 1990, and bare identifying marks to that effect.
E. Elation Professional® reserves the right to make changes in design and/or improvements upon its
products without any obligation to include these changes in any products theretofore
manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory
supplied with products described above. Except to the extent prohibited by applicable law, all
implied warranties made by Elation Professional® in connection with this product, including
warranties of merchantability or fitness, are limited in duration to the warranty period set forth above.
And no warranties, whether expressed or implied, including warranties of merchantability or fitness,
shall apply to this product after said period has expired. The consumer’s and or Dealer’s sole remedy
shall be such repair or replacement as is expressly provided above; and under no circumstances shall
Elation Professional® be liable for any loss or damage, direct or consequential, arising out of the use
of, or inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professional® Products and
supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore
published.
www.elationlighting.com
7 RAYZOR Q12 ZOOM™ User Manual ver 1
SAFETY INSTRUCTIONS
The RAYZOR Q12 ZOOM™ is an extremely sophisticated piece of electronic
equipment. To guarantee a smooth operation, it is important to follow the
guidelines in this manual. The manufacturer of this device will not accept
responsibility for damages resulting from the misuse of this fixture due to the
disregard of the information printed in this manual.
This device falls under PROTECTION CLASS 1. It’s essential this device be
grounded properly. Only qualified personnel should perform all electrical
connections.
KEEP THIS FIXTURE AWAY FROM RAIN AND MOISTURE!
UNPLUG POWER BEFORE SERVICING FIXTURE
NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE
SENSITIVE PERSONS MAY SUFFER AN EPILETIC SHOCK
For proper operation, follow the Installation guidelines described in this manual. Only qualified
and certified personnel should perform installation of this fixture and only the original rigging parts
(brackets) included with this fixture should be used for installation. Any modifications will void the
original manufactures warranty and increase the risk of damage and/or personal injury.
Never look directly into the light source of this fixture to prevent risk of injury to your retina, which
may induce blindness. Those suffering from EPILEPSY should avoid looking directly into the light
source of this unit at all times.
The fan and air inlets must remain clean and never blocked. Allow approx. 6” (15cm) between
this fixture and other devices or a wall for proper cooling.
Always disconnect from main power source before performing any type of service and/or
cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by
tugging the wire portion of the cord.
Do not operate this fixture if the power cord has become frayed, crimped and/or damaged. If
the power cord is damaged, replace it immediately with a new one of similar power rating.
www.elationlighting.com
8 RAYZOR Q12 ZOOM™ User Manual ver 1
GENERAL GUIDELINES
NEVER OPEN THIS FIXTURE WHILE IN USE!
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.
This fixture is a professional lighting effect designed for INDOOR / DRY LOCATIONS
ONLY on stage, in nightclubs, theatres, etc.
Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while
operating, to prevent any fire hazard.
Minimum distance of inflammable materials from the surface 1.6 feet (0.5m).
The fixture must be installed in a location with adequate ventilation, at least 1.5
feet (.5m) from adjacent surfaces. Be sure no air ventilation slots are blocked.
DO NOT attempt installation and/or operation without knowledge how to do so.
DO NOT allow operation by persons who are not qualified to operate this type of
fixture. Most damages are the result of operations by nonprofessionals.
Consistent operational breaks may ensure the fixture will function properly for
many years to come.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
Always install the fixture with an appropriate safety cable. When installing the
fixture in a suspended environment, always use mounting hardware that is no less
than M10 x 25 mm, also be sure the hardware is insert in the pre-arranged screw
holes in the bracket of the fixture.
Use the original packaging and materials to transport the fixture in for service.
DO NOT TOUCH the housing bare-hand during its operation. Turn OFF the power
and allow approximately 15 minutes for the fixture to cool down before replacing
or serving.
www.elationlighting.com
9 RAYZOR Q12 ZOOM™ User Manual ver 1
FIXTURE OVERVIEW
1. LED Array
2. DC Switch
3. Microphone
4. LCD Menu Function Display
5. ENTER Button
6. LEFT Button
7. DOWN Button
8. RIGHT Button
9. MODE/ESC Button
10. UP Button
11. powerCON IN
12. powerCON OUT
13. Fuse
14. Power Switch
15. 5pin DMX OUT
16. 5pin DMX IN
17. Carrying Handle(s)
www.elationlighting.com
10 RAYZOR Q12 ZOOM™ User Manual ver 1
FIXTURE INSTALLATION
FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 ft (1.5m) away from any flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installations.
CAUTIONS
For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.
Ambient operating temperature range for this fixture is 14° to 113°F. (-10° to 45°C)
Do not use the fixture under or above this temperature.
Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture. (230 lbs / 104 kg)
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing.
www.elationlighting.com
11 RAYZOR Q12 ZOOM™ User Manual ver 1
MOUNTING POINTS
Overhead mounting requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic
safety inspection of all installation material and the device. If you lack these
qualifications, do not attempt the installation yourself. Improper installation can
result in bodily injury.
Fixture is fully operational in the specific mounting positions as illustrated below.
SAFETY CABLE
Always use a Safety Cable whenever installing this fixture in a suspended
environment to ensure the fixture will not drop if the clamp fails.
www.elationlighting.com
12 RAYZOR Q12 ZOOM™ User Manual ver 1
CLAMP MOUNTING
The RAYZOR Q12 ZOOM™ provides a unique mounting bracket assembly that
integrates the bottom of the base, the included Omega Brackets (x2) and safety
cable rigging point in one unit (see the illustration below). When mounting this fixture
to truss be sure to secure an appropriately rated clamps to the included omega
brackets using a M10 screw fitted through the center hole of the Omega Bracket. Be
sure to attach the included Safety Cable to the fixture using the safety cable rigging
point integrated in the base assembly.
SECURING
Regardless of the rigging option you choose for your RAYZOR Q12 ZOOM™ always be
sure to secure your fixture with a safety cable. The fixture provides a built-in rigging
point for a safety cable on the hanging bracket as illustrated above. Be sure to only
use the designated rigging point for the safety cable and never secure a safety
cable to a carrying handle.
Loading...
+ 25 hidden pages