Elation Rayzor Q7, Rayzor Q12 User Manual

RAYZOR&Q7™&
User&Manual&2.0
www.elationlighting.com&
2&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
&
www.elationlighting.com&
3&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
CONTENTS
1. General Information……………………………………………………… ………… …….……………... 4
Introduction……… ……………………… ……………………… ……………………… .………. 4
Unpacking………………………………………………………..…………………… … .…..….. 4
Box Contents……………………………………...……………………………………………… 4
Customer Support…………………………………………….…………………….……………. 5
Warranty Registration………………………………………………………………….…..……. 5
2. Safety Instructions…………………………………… ……… …… ……..............................…………. 6
3. General Guidelines……………………………………………………………………………………….. 7
4. Features……………………………………………………………………………………………………. 8
5. Fixture Overview…………………………………………… …… …… …… …… … …… …… …....…. 9
6. Mounting and Installation……………………………………………………………………….....……. 11
Mounting Points………………………………………………………………………….………. 12
Securing………………………………………………………………………………………….. 13
7. Understanding DMX………………………………………………………………………………… …... 14
DMX Controller Connection……………...…………………………………………………….. 15
DMX Terminator…………………………………………………………………………… ……. 16
DMX Addressing……………………………………………………………………… .………... 17
8. Fixture Menu…………………………………………………………………………………..………….. 18
Menu Functions………………………………………………………………………………….. 19
Function……………………………………………………………………………….…. 21
Information…………………………………………………………………………….… 23
Personality………………………………………………………………………………. 25
Reset Function………………………………………………………………………….. 32
Effect Adjust………………………………………………………………………….…. 32
User Mode Setting……………………………………………………………………... 34
Edit Program……………………………………………………………………………. 35
9. DMX Channel Values....……………………… ……………………… ………………..…………….. 40
LED Groups………………………… …… ……………………………………………………… 42
10. Error Message……………………………………………………… …… ……… …… …… ……… …… . 43
11. Snoot & Diffusion Filter Installation…………………………………………………………………….. 44
12. Cleaning and Maintenance……………………………………………………………………………… 45
13. Photometric Data……………………………………………………………… …… ……… ….……….. 46
14. Dimensional Drawings………………………………………………….………………………………. 47
15. Circuit Schematic………...……………………………………………………… …… ..………………. 48
16. Warranty…………………………………………………………………………………….……………. 49
17. Technical Specifications…………………………………………...………………………….………… 50
18. Related Items & Accessories…………………………………………………………………………… 51
www.elationlighting.com&
4&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
1. GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and reliable lighting
fixtures on the market today! The RAYZOR Q7™ has been designed to perform reliably
for years when the guidelines in this booklet are followed. Please read and understand
the instructions in this manual carefully and thoroughly before attempting to operate this
unit. These instructions contain important information regarding safety during use and
maintenance.
UNPACKING
Thank you for purchasing the RAYZOR Q7™ by Elation Professional®. Every RAYZOR
Q7™ has been thoroughly tested and has been shipped in perfect operating condition.
Carefully check the shipping carton for damage that may have occurred during shipping.
If the carton appears to be damaged, carefully inspect your unit for damage and be sure
all accessories necessary to operate the unit have arrived intact. In the event damage
has been found or parts are missing, please contact our customer support team for
further instructions. Please do not return this unit to your dealer without first contacting
customer support at the number listed below. Please do not discard the shipping carton
in the trash. Please recycle whenever possible.
BOX CONTENTS
(1) powerCON Power Cable
(1) 5-Pin XLR Cable (Initial units may have 3-pin XLR Cable)
(1) Omega Clamp
(1) Safety Cable
Manual & Warranty Card
MANUAL UPDATES
Please check www.elationlighting.com for the latest revision/update of this manual.
www.elationlighting.com&
5&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
CUSTOMER SUPPORT
Elation Professional® provides a customer support line, to provide set up help and to
answer any question should you encounter problems during your set up or initial
operation. You may also visit us on the web at www.elationlighting.com for any
comments or suggestions. For service related issues please contact Elation
Professional®. Service Hours are Monday through Friday 8:00 a.m. to 5:00 p.m. Pacific
Standard Time.
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com Forum: www.ElationLighting.com/forum
WARRANTY REGISTRATION
The RAYZOR Q7™ carries a two year (730 days) limited warranty. Please fill out the
enclosed warranty card to validate your purchase. All returned service items whether
under warranty or not, must be freight pre-paid and accompany a return authorization
(R.A.) number. The R.A. number must be clearly written on the outside of the return
package. A brief description of the problem as well as the R.A. number must also be
written down on a piece of paper and included in the shipping container. If the unit is
under warranty, you must provide a copy of your proof of purchase invoice. Items
returned without a R.A. number clearly marked on the outside of the package will be
refused and returned at customer’s expense. You may obtain a R.A. number by
contacting customer support at 323-582-3322.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are
not subject to any warranty claims and/or repairs.
www.elationlighting.com&
6&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
2. SAFETY INSTRUCTIONS
The RAYZOR Q7™ is an extremely sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow the guidelines in this manual. The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual.
For stage operation, follow the Mounting and Installation guide described in Chapter 6 of this manual.
Operating the RAYZOR Q7™ without suited safety aids such as safety cables and/or clamps can
increase the risk of damage and/or personal injury.
Installation should only be performed by qualified and certified personnel.
When mounting this fixture, use only the original rigging parts included with this fixture. Any structural
modification will void the original manufactures warranty and may increase the risk of damage and/or
personal injury.
To prevent and/or reduce the risk of electrical shock and/or fire, DO NOT EXPOSE THIS UNIT TO
RAIN OR MOISTURE.
Those suffering from EPILEPSY should avoid looking directly into the light source of this unit at all
times.
Never look directly into the light source of this fixture. You risk injury to your retina, which may induce
blindness.
Never touch the fixture during normal operation. This can cause severe personal injuries and/or
damage to the fixture.
Always be sure the fan and air inlets remain clean and are never blocked. Allow approx 6” (15cm)
between this fixture and other devices or a wall to allow for proper cooling.
Do not attempt to operate this fixture if the power cord has become damaged or frayed. Be sure the
power cord is never crimped and/or damaged. If the power cord is damaged, replace it immediately
with a new one of similar power rating.
Be sure to unplug the RAYZOR Q7™ from the power outlet before performing any service related
issues.
This device falls under protection-class 1, therefore it is essential that this device be grounded properly.
Only qualified personnel should perform all electrical connections. Be sure the available voltage
matches the voltage requirements of this device.
Always disconnect from main power source before performing any type of service and/or cleaning
procedure. Only handle the power cord by the plug end. Never pull out the plug by tugging the wire
portion of the cord.
www.elationlighting.com&
7&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
3. GENERAL GUIDELINES
NEVER OPEN THIS FIXTURE WHILE IN USE!
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.
This fixture is a professional lighting effect designed for use on stage, in nightclubs,
theatres, etc. Do not attempt installation and/or operation without proper knowledge
of how to do so.
Do not permit operation by persons who are not qualified for operating this type of
theatrical fixture. Most damages are the result of operations by nonprofessionals.
If this fixture is exposed to extreme temperatures due to environmental changes, do
not power the fixture on until it has reached room temperature. Condensation could
damage the fixture.
Consistent operational breaks may ensure the fixture will function properly for many
years to come.
Do not shake fixture, avoid brute force when installing and/or operating the device.
When choosing an installation location, please be sure this fixture will not be exposed
to extreme heat, moisture, and/or dust. The minimum distance between this fixture
and other devices or wall and/or flat surface should be at least 0.5 meter (1.5 ft).
When using quick release “OMEGA” Cam-Lock system, be sure the four quick lock
fasteners are locked in the quick lock holes correctly.
Always install the fixture with an appropriate safety cable. When installing the fixture
in a suspended environment, always use mounting hardware that is no less than M10
x 25 mm, also be sure the hardware is insert in the pre-arranged screw holes in the
base of the fixture.
Please use the original packaging and materials to transport the fixture in for service.
www.elationlighting.com&
8&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
4. FEATURES
7 x 15W Quad Color RGBW LEDs
100,000 Hour Rated LED Life
7° to 13° Field Angle Range @7.5M
Max 1,743 Lux @7.5M
Strobe 1 – 18 Flashes Per Second
Dimming 0-100% and Blackout for all LEDS
4 Zone Chase Effects
8 Auto Program Macros
USITT DMX 512 with15 (Basic), 17 (Standard), and 29 (Extended) DMX Channel Operation
5-pin DMX In/Out Connection
powerCON In/Out
Full Color Reversible (180° Flip) LCD Menu Control Display and Touch Panel
Rechargeable Battery For Menu Control Display and Touch Panel
High Speed Adjustable 16-Bit Resolution Movement
540° / 630° / 540° - 90° Offset PAN x 265° TILT
100-240v / 50-60Hz Power Input
ST 250v T3.15a Fuse
140W Max Power
Flicker Free Operation for TV and Film
Single Omega Bracket Mounting
CE and cETLus Approvals PENDING
www.elationlighting.com&
9&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
5. FIXTURE OVERVIEW
1: LED Lens Assembly
2: DC Switch
3: Microphone
4: LCD Menu Control Display
5: Mode/Esc Button
6: ENTER Button
7: Left Button
8: Down Button
9: Up Button
10: Right Button
11: 5-Pin DMX Out
12: 5-Pin DMX In
13: Power Switch
14: Fuse
15: Power In
16: Power Out
www.elationlighting.com&
10&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
1. LED Assembly – RGBW Quad LEDs comprise the LED assembly.
2. DC Switch – Controls menu and display power when disconnected from main power.
3. Microphone – Captures external low frequency sounds to trigger the unit in Sound
Active mode. Designed to capture low frequency sounds only, tapping on the
microphone and/or high-pitched sounds may not trigger unit.
4. LCD Menu Control Display – Full color LCD animated menu display.
5. Mode/Esc Button – Used to access the menu functions and exit the current command.
6. Enter Button – Used to enter into or lock a certain menu function.
7. Left Button – Used to toggle through the menu display.
8. Down Button – Used to toggle down or back through the menu functions and settings.
9. Up Button – Used to toggle forward through the menu functions and settings.
10. Right Button – Used to toggle through the menu display.
11. 5-Pin DMX In – Accepts incoming DMX signal via a male 5-pin XLR jack.
12. 5-Pin DMX Out – Sends incoming DMX signal to the next fixture in the DMX chain via a
female 5-pin XLR jack.
13. Power Switch – Used to power the unit ON or OFF.
14. Fuse Holder Assembly – Houses 250v T3.13A GMA safety fuse. Always replace with
an exact match unless otherwise specified by an authorized Elation Service Technician.
Using a fuse other than that specified could seriously damage the unit and may void the
manufactures warranty.
15. Power In – Power connection (powerCon) to power source
16. Power Out – Power connection (powerCon) to daisy chain to another unit.
www.elationlighting.com&
11&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
6. MOUNTING AND INSTALLATION
T h e$el e c tr i c $ c o n ne c ti on $ m u s t$o n l y $ b e$ c a r r i ed $o u t$b y $a $qu al i f i e d $el ec tri c i a n .$
CAUTIONS
Recommended ambient temperature for this fixture is between 14°F to 113°F
(-10°C to 45°C). Do not use the fixture under or above this temperature.
For added protection, mount the fixture in areas outside walking paths, seating areas, or
in areas were unauthorized personnel might reach the fixture.
Before mounting the fixture to any surface, make sure the installation area can hold a
minimum point load of 10 times the weight of the fixture. (46Kgs / 102 Lbs)
Fixture installation must always be secured with a secondary safety attachment, such as
an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing the fixture.
www.elationlighting.com&
12&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
MOUNTING POINTS
Overhead mounting requires extensive experience, including amongst others calculating
working load limits, installation material being used, and periodic safety inspection of all
installation material and the device. If you lack these qualifications, do not attempt the
installation yourself. Improper installation can result in bodily injury.
Be sure the fixture is kept at least 0.5m (1.5 feet) away from any flammable materials
(decoration etc.).
www.elationlighting.com&
13&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
SECURING
Secure the clamp to the bracket using a M12 screw fitted through the Ф13 center hole.
Insert the ¼ Turn Twist Locks of the first Omega bracket into the respective holes on the
bottom of the device. Tighten the Twist Locks a ¼ turn clockwise.
Install the second Omega bracket on the top of the device in the same way.
Pull a safety cable through the holes on the bottom of the base and over the trussing
system or a safe installation.
Notice: This step is very important to ensure the fixture will not drop out by the
damage of the clamp.
www.elationlighting.com&
14&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
7. UNDERSTANDING DMX
DMX-512
DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and
controller manufactures as a form of communication between intelligent fixtures and
controllers. DMX allows all makes and models of different manufactures to be linked
together and operate from a single controller. This is possible as long as all the fixtures and
the controller are DMX compliant. A DMX controller sends the DMX data instructions to the
fixture allowing the user to control the different aspects of an intelligent light. DMX data is
sent out as serial data that travels from fixture to fixture via data “IN” and data “OUT” XLR
terminals located on the fixtures (most controllers will only have output jacks).
DMX LINKING
To ensure proper DMX data transmission, always use proper DMX cables and a terminator.
When using several DMX fixtures try to use the shortest cable path possible. Never split a
DMX line with a “Y” style connector. The order in which the fixtures are connected in a DMX
line does not influence the DMX addressing. For example; a fixture assigned a starting DMX
address of 1 may be placed anywhere in the DMX chain, at the beginning, at the end, or
anywhere in the middle. The DMX controller knows to send data assigned to address 1 to
that fixture no matter where it is located in the DMX chain. The RAYZOR Q7™ can be
controlled via DMX-512 protocol. The RAYZOR Q7™ is a 64-channel DMX fixture. The
DMX address is set electronically using the controls on the LCD menu.
DATA CABLE (DMX Cable) REQUIREMENTS (For DMX and Master/Slave Operation)
Your fixture and your DMX controller require a standard 3-pin or 5-pin XLR connector for
data input and data output (see figure below). If you are making your own cables, be sure to
use two conductor, shielded digital DMX cable rated at 120 ohms; this cable is designed for
DMX transmission and may be purchased from your Elation dealer or at most professional
lighting retailers. Your cables should be made with a male and female XLR connector on
either end of the cable. Also, remember that a DMX line must be daisy chained and cannot
be split, unless using an approved DMX splitter such as the Elation Opto Branch 4™ or DMX
Branch/4™.
www.elationlighting.com&
15&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
Be sure to follow the above figure when making your own cables. Do not use the ground lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR outer casing. Grounding the shield could cause a short circuit and erratic behavior.
DMX-512 CONTROLLER CONNECTION
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the
other side to the male 3-pin XLR input of the RAYZOR Q7™ (Please refer to the diagram
below.). You can chain multiple panels together through serial linking. The cable that should
be used is two conductor, shielded DMX cable with XLR input and output connectors.
Always be sure daisy chain your in and out data connections, never split or “Y” your DMX
connections unless you are using an approved DMX splitter such as the Elation Opto Branch
4™ or DMX Branch/4™.
Address 35 Address 18 Address 1
www.elationlighting.com&
16&&&&&&&&&&&&&&&&&&&&&&&&&RAYZOR'Q7™'User'Manual'2.0
DMX-512 CONNECTION WITH DMX TERMINATOR
A DMX terminator should be used in all DMX lines especially in longer runs. The use of a
terminator may avoid erratic behavior in your DMX line. A terminator is a 120 ohm 1/4 watt
resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy
chain to terminate the line. Using a line terminator (Elation part: DMX T PACK) will decrease
the possibilities of erratic behavior.
5-Pin XLR DMX CONNECTORS
Some manufactures use 5-pin XLR connectors for DATA transmission in place of 3-pin.
5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard
5-pin XLR connectors in to a 3-pin line a cable adaptor must be used, these adaptors are
readily available at most electric stores. The following chart details a proper cable
conversion.
Loading...
+ 36 hidden pages