Elation POWER SPOT 700CMY User Manual

Revised 4/4/2007 visage
POWER SPOT 700CMY
User Manual
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 2
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 3
Table of Contents
Introduction...........................................................................................................................4
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 4
INTRODUCTION: Congratulations, you have just purchased one of the most innovative
and reliable lighting fixtures on the market today! The Power Spot 700CMY™, has been
designed to perform reliably for years when the guidelines in this booklet are followed.
Please read and understand the instructions in this manual carefully and thoroughly
before attempting to operate this unit. These instructions contain important information
regarding safety during use and maintenance.
UNPACKING: Thank you for purchasing the Power Spot 700CMY™ by Elation
Professional®. Every Power Spot 700CMY™ has been thoroughly tested and has been
shipped in perfect operating condition. Carefully check the shipping carton for damage
that may have occurred during shipping. If the carton appears to be damaged, carefully
inspect your unit for damage and be sure all accessories necessary to operate the unit
have arrived intact. In the event damage has been found or parts are missing, please
contact our customer support team for further instructions. Please do not return this unit
to your dealer without first contacting customer support at the number listed below.
CUSTOMER SUPPORT: Elation Professional® provides a customer support line, to
provide set up help and to answer any question should you encounter problems during
your set up or initial operation. You may also visit us on the web at
www.elationlighting.com for any comments or suggestions. For service related issue
please contact Elation Professional®. Service Hours are Monday through Friday 9:00
a.m. to 5:00 p.m. Pacific Standard Time.
Voice: (866) 245-6726
Fax: (323) 582-3108
E-mail: support@elationlighting.com
Forum: www.ElationLighting.com/forum/
Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit
to rain or moisture.
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself, doing so will void your manufactures warranty.
Please do not discard the shipping carton in the trash. Please recycle whenever
possible.
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 5
WARRANTY REGISTRATION: The Power Spot 700CMY™ carries a two year (730 days)
limited warranty. Please fill out the enclosed warranty card to validate your purchase. All
returned service items whether under warranty or not, must be freight pre-paid and
accompany a return authorization (R.A.) number. The R.A. number must be clearly
written on the outside of the return package. A brief description of the problem as well as
the R.A. number must also be written down on a piece of paper and included in the
shipping container. If the unit is under warranty, you must provide a copy of your proof of
purchase invoice. Items returned without a R.A. number clearly marked on the outside of
the package will be refused and returned at cutomers exspence. You may obtain a R.A.
number by contacting customer support at (323) 582-3322.
DISCHARGE LAMP WARNING: This fixture is fitted with a discharge
lamp, which is highly susceptible to damage if improperly handled.
Never touch the lamp with your bare hands, as the oil from your
hands will shorten lamp life. Also, never move the fixture until the
lamps have had ample time to cool. Remember, lamps are not
covered under warranty conditions.
This fixture emits intense UV radiation, which is harmful to the eyes and skin. The
intense luminance of the lamp can cause severe damage to the retina. Never operate
this fixture with the protective covers removed, these covers have been specially
designed to shield against UV radiation.
Epileptic Warning: Those suffering from epilepsy should avoid looking directly into the
lamp at all times.
Avoid switching the fixture on and off repeatedly in short intervals, as this will reduce
lamp life and intensity.
To achieve the intensity associated with discharge lamps, these lamps use a gas
sealed in a high-pressure environment to emit a brilliant output. Due to the high
pressure involved with the construction of the lamp, the lamp may explode during
prolonged extensive use. This risk is increased with age; added care is encouraged
when dealing with older lamps. Thus, lamp should always be replaced at the end of
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 6
their recommended duty cycle. Extreme caution should be used when operated this or
any fixture fitted with a gas discharge lamp.
Never open this fixture while in use!
During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp.
This device falls under protection-class 1. Therefore it is essential that the device be grounded properly.
All electrical connections must performed by qualified personal.
Be sure the available voltage matches the voltage requirements of the unit.
Be sure the power cord is never crimped or damaged. If the power cord is damaged, replace it immediately with a new one of similar power rating.
Always disconnect from main power before performing any type of service or any cleaning procedure.
Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of the cord.
Please be aware that damages caused by modifications to the device are not subject to warranty.
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 7
2. SAFETY INSTRUCTIONS
The Power Spot 700CMY™ is an extremely sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow the guidelines in this manual. The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual.
1. Always be sure that the fan and the air inlets remain clean and are never
blocked. Allow about 6” (15cm) between this fixture and other devices or a wall
to allow for proper cooling.
2. Never touch the fixture during normal operation. This can cause severe
personal injuries and/or damage to the fixture.
3. Be sure to unplug the POWER SPOT 700CMY™ from the power outlet before
performing any service related issues.
4. Lamp Replacement; Allow at least 30 minutes after disconnecting main power
before you open the POWER SPOT 700CMY™. To prevent personal injury,
never touch the lamp if you are not absolutely sure it has cooled.
5. Never look directly into the lamp beam. You risk injury to your retina, which may
induce blindness.
6. Be sure to track and record the lamp running time. The lamp should be
changed at the end of the specified lamp life, regardless of lamp output. You
may also have to change the lamp if it shows any deformations or damage.
The same is with all glass components, color filters, lenses and mirrors.
7. For safe operation, follow the Installation guide described in chapter two of this
manual. Operating the POWER SPOT 700CMY™ without suited safety aids
such as safety cables or clamps can increase the risk of damage and/or
personal injury.
8. Installation should only be performed by qualified and certified personal.
9. When mounting this fixture, use only the original rigging parts included with this
fixture. Any structural modification will void the original manufactures warranty
and may increase the risk of damage and/or personal injury.
10. To reduce the risk of fire or shock, do not expose this unit to rain or moisture.
11. Do not attempt to operate this fixture if the power cord is frayed or damaged.
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 8
3. FEATURES
Pan 530° / Tilt 280°
3 operation mode: DMX controlled, stand alone or sound activated
Electronic Power Supply
Control board with 4-digit display
Digital display can be turned 180° to fit different installation position
CMY Subtractive Color Mixing
Additional Color Wheel: 8 User replacable colors
2 Gobo Wheels:
o Fixed: 9 plus open
o Rotating: 7 Suer replaceable plus open
Auto test for all functions
Automatic Pan/Tilt Correction
Glass Dichroic Reflector for Even Lamp Output
Anti-Reflective Coated Lenses
Brilliant MSR700/2 Lamp (700w, 1000Hrs, 7200K)
USITT DMX-512 Complaint
Value of each DMX-channel can be displayed
Uses 24 DMX Channels (16-bit mode)
Variable Frost Filter
Variable Color Correction Filter
3-Facet Prism
Variable Animation Wheel
User Replaceable Color and Gobos
Intergrated Tilt Lock System
Modular Construction
Variable Zoom: 14˚~32˚ (Beam Angle)
Motor Driven Focus
Variable Iris (4%~100%)
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 9
4. GENERAL GUIDELINES
This fixture is a professional lighting effect designed for use on stage, in nightclubs, in
theatres, etc. Do not attempt operation or installation without a proper knowledge on how
to so.
This fixture was designed for indoor use only.
Consistent operational breaks may ensure that the fixture will function properly for many
years to come.
Do not shake the fixture around. Avoid brute force when installing or operating the device.
While choosing an installation location, please be sure that the fixture will not be
exposed to extreme heat, moisture or dust. The minimum distance between the fixture
and a wall or flat surface should be at least .5 meter (about 1.5ft).
Always install the fixture with an appropriate safety cable. When installing the fixture in a
suspended environment always be to use mounting hardware no less than M10 x 25
mm, also be sure the hardware is insert in the pre-arranged screw holes in the base of
the fixture.
When using the quick release “Omega” cam-lock system, be sure the four quick lock
fasteners are locked in the quick lock holes correctly, see page 16 for more information
on the proper mounting procedures.
Do not attempt to operate this fixture until you have familiarized yourself with its functions.
Do not permit operation by persons not qualified for operating this type of theatrical
fixture; most damages are the result of operation by person unfamiliar with the operation
of this type of fixture.
If service is ever required, please use the original packaging to transport the fixture in for
service.
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 10
Transportation and Handling
The POWER SPOT 700CMYcomes with two carrying handles built into the base.
Always transport the fixture by these handles. Never lift or carry the POWER SPOT
700CMY™ by the yoke (head assembly) this can seriously damage the unit and will void
your manufactures warranty.
Connections
Power supply:
Electronic ballast with:
90~260 Volts, 50~60 Hz,
Grounded contact type plug – Neutrik Powercon
Connected load 1000W <=> 4.5 A (blind current compensation).
NOTE: The universal power supply will accept any voltage source as detailed
above without any type of internal or user modifications.
DMX:
USITT DMX 512 Standard input/output, 3 pole connectors.
[+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 1
Fuse Requirements:
The POWER SPOT 700CMY’s electronic and lamp systems are protected by two
GMA (5x20mm) external fuses:
Lamp: 250v/10A (120v Operation) or 250v/5A (220v Operation)
Electronics: 250v/2A (120v Operation) or 250v/1A (220v Operation)
The fuse requirements are clearly printed on the side of the fixture.
Always disconnect main power before changing the fuse!
Always replace with the exact same type fuse unless otherwise specified by
an authorized Elation® service technician. Replacing with anything other
than the specified fuse can severely damage your fixture and will void your
manufactures warranty.
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 11
5. FIXTURE LAYOUT
1. Moving Head
2. Carrying Handles
3. LED Menu Display
4. Head Tilt Lock
5. Omega Clamp
6. Software-Update
Connector
7. Microphone
Sensitivity
8. DMX- Input
9. DMX- Output
10. Fan (air inlet/outlet)
11. Electronics Fuse
12. Main Power Supply
(Powercon)
13. Power On/Off
14. Lamp Fuse
MaxMin
DMX IN DMX OUT
Software Update
1.Ground
2.Data -
3.Data +
Mic Sensitivity
6
7
8 9
10
15
POWER
Power Input: 90 - 260 VAC, 50/60 Hz
Lamp Fuse
Electronic
Fuse
10
11
12
13 14
15
T
2
A
@
11
5
V~
T
1
A
@
2
3
0
V
~
T
1
0
A
@
1
1
5
V
~
T
5A
@
2
3
0
V
~
0
1
2
2
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 12
15. 4-Segment LED
Menu Display
16. Mode Button
17. Enter Button
18. Up Button
19. Down Button
Side View - Menu and Display
1. Head Assembly – The head assembly consist of the main output lens, and either the standard or CMY control module.
2. Carrying Handle – The fixtures includes two built-in carrying handles. Be sure to always handle the fixture by the built-in carrying handles. Never lift or carry the fixture by the head or retaining arms as this could cause serious damage to the fixture and void your manufactures warranty.
3. 4-Segment Menu Display – This display details all the various menu functions. See page XX for a detailed breakdown of the operating menu.
4. Tilt Lock – This lock will hold the head assembly in place for transportation and/or service. Depress the lock button to lock and unlock the head assembly. The head will lock in a 90˚ or 45˚ orientation. Always be sure to unlock the head assembly before applying main power to the unit. Failure to do so will result in a start-up error and may damage the unit.
5. Omega Clamp - This fixture uses a cam-lock clamp system that allows a quick and efficient means to secure a clamp to the unit. To attach a clamp to the unit,
15
161718
19
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 13
attach a clamp that is rated to handle the weight of the unit to your omega clamp. After a clamp has been attached to the omega clamp, attach the cam locks to the designated position on the bottom of your unit. Lock the cam locks into position by turning the wing nuts 90°. See page XX for proper clamp mounting and assembly.
6. Firmware Connection – This connector is for use by an authorized technician only. This connector is used to upgrade the operating software and to test the fixture.
7. Microphone Sensitivity Adjustment Knob – This knob is used to adjust the frequency sensitivity of the internal microphone when operating in “audio” mode. When the knob is turned counter-clockwise the unit is less sensitive to sound. When the knob is turned clockwise the unit is more sensitive sound.
8. DMX Input Jack – This 3-Pin XLR jack is used to receive an incoming DMX signal.
9. DMX Output Jack – This 3-Pin XLR jack is used to send an outgoing DMX signal. For best results this jack should be terminated if it is the last fixture in a DMX daisy-chain (see termination on page 14).
10. Internal Cooling Fan – This fixture is equipped with two high-velocity variable speed fans mounted in the base to aid in the cooling process. These fans are designed to vary their velocity at different operating temperatures. When the fixture reaches a predetermined internal operating temperature the fans function at high speeds. The higher speeds provide better cooling associated with higher operating temperatures during long use. When the fixture is operating at a lower temperature the fans operate at low speed. Be sure to keep all vents clean, blocked cooling vents can shorten lamp life and reduce the fixtures reliability. For more information on the fan functions see page 23, section 3.9.7.
11. Electronics Fuse Holder – This housing holds a 250v/2A GMA fuse (120v operation). Never defeat this fuse, this fuse is designed to protect the electronics in the event of severer power fluctuations. In the event of fuse failure, always be sure to replace this fuse with an exact match unless otherwise instructed by an authorized Elation technician.
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 14
12. Powercon Connector – This power jack is designed to be used only with the Neutrik Powercon adapter included with your fixture. This jack provides main power to your fixture.
13. Power Switch – The switch is used to control main power to fixture’s electronics.
14. Lamp Fuse Holder – This housing holds a 250v/10A GMA fuse (120v operation). Never defeat this fuse. This fuse is designed to protect the lamp in the event of severer power fluctuations. In the event of fuse failure, always be sure to replace this fuse with an exact match unless otherwise instructed by an authorized Elation technician.
15. 4-Segment Menu Display – This display details menu functions.
16. Mode Select Button – This button is used to access the fixture’s main system menu and on-board programming functions.
17. Enter Select Button – This button is used to select and confirm a menu function when working in the fixture’s operating system.
18. Down Select Button – This button is used to scroll backwards when navigating through the system menu.
19. Up Select Button - This button is used to scroll forward when navigating through the system menu.
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 15
6. MOUNTING AND INSTALLATION
MOUNTING
The POWER SPOT 700CMY™ is fully operational in two different mounting
positions, hanging upside from a ceiling or set on a flat level surface. To avoid
internal damage to the unit, never mount the unit on its side as illustrated
below. Be sure this fixture is kept at least 0.5m away from any flammable
materials (decoration etc.). Install a safety cable that can hold at least 10 times
the weight of the fixture. Never use the carrying handles for secondary
attachment.
Refer to regulations BGV C1 (formerly VBG 70) and DIN VDE 0711-217 for proper installation in Europe To ensure proper installation, only qualified staff should attempt installation.
Mounting points
Overhead mounting requires extensive experience, including amongst others calculating
working load limits, a fine knowledge of the installation material being used, and
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 16
periodic safety inspection of all installation material and the fixture. If you lack these
qualifications, do not attempt the installation yourself. Improper installation can result in
bodily injury.
CAUTION! Be sure a qualified electrician performs all electrical connections.
Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet.
Clamps
The POWER SPOT 700CMY™ has been designed to hold multiple clamps to the bottom
of the unit in several different orientations. Always use an appropriately rated clamp to
mount this unit to truss. Refer to the printed instructions on the bottom of the fixture for
proper clamp installation.
a) Cam lock System: This system allows a quick and efficient means to
secure a clamp to the unit. To attach a clamp to the unit, attach a clamp
that is rated to handle the weight of the unit to your cam lock. After a
clamp has been attached to the cam lock, attach the cam locks to the
designated position on the bottom of your unit. Lock the cam locks into
position by turning the wing nuts 90°.
90°
b) Be sure to always use two cam locks mounted to the bottom of unit to
ensure safe truss mounting (each two opposite threads max. M10x20).
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 17
Secure the POWER SPOT 700CMY™
Regardless of the rigging option you choose for your POWER SPOT 700CMY™ always
be sure to secure your fixture with a safety cable. The fixture provides a built-in rigging
point for a safety cable on the underside of the fixture, be sure to use this point and never
secure a safety cable to a carrying handle.
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 18
7. UNDERSTANDING DMX
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most
lighting and controller manufactures as a form of communication between intelligent
fixtures and controllers. A DMX controller sends DMX data instructions from the controller
to the fixture. DMX data is sent out as serial data that travels from fixture to fixture via the
DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers
only have a DATA “OUT” terminals). DMX Linking: DMX is a language allowing all makes
and models of different manufactures to be linked together and operate from a single
controller, as long as all fixtures and the controller are DMX compliant. To ensure proper
DMX data transmission, when using several DMX fixtures try to use the shortest cable
path possible. The order in which fixtures are connected in a DMX line does not
influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may
be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the
middle. Therefore, the first fixture controlled by the controller could be the last fixture in
the chain. When a fixture is assigned a DMX address of 1, the DMX controller knows to
send DATA assigned to address 1 to that fixture, no matter where it is located in the DMX
chain.
Data Cable (DM X Cable) Requirements (For DMX and Master/Slave Operation): The
POWER SPOT 700CMY™ can be controlled via DMX-512 protocol. The POWER SPOT
700CMY™ is a 24 channel DMX fixture. The DMX address is set electronically using the
controls on the side panel of the fixture. Your fixture and your DMX controller require a
standard 3-pin XLR connector for data input and data output (Figure Below). If you are
making your own cables, be sure to use standard two conductor shielded cable (This
cable may be purchased from your Elation dealer or at most professional lighting
retailers). Your cables should be made with a male and female XLR connector on either
end of the cable. Also, remember that DMX cable m us t be dais y chained and can not be
split.
Power Spot 700CMY™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 19
Notice: Be sure to follow the figure on the previous page when making your own
cables. Do not use the ground lug on the XLR connector. Do not connect the cable’s
shield conductor to the ground lug or allow the shield conductor to come in contact
with the XLR’s outer casing. Grounding the shield could cause a short circuit and
erratic behavior.
DMX-512 control connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the
other side to the male 3-pin XLR input of the moving head (Please refer to the diagram
below.). You can chain multiple moving heads together through serial linking. The cable
needed should be two conductor, shielded cable with XLR input and output connectors.
Always be sure daisy chain your in and out data connections, never split or “Y” your DMX
connections unless you are using an approved DMX splitter such as the Elation Opto
Branch 4™ or DMX Branch/4™.
Special Note: Line Termination. When longer runs of cable are used, you may need
to use a terminator on the last fixture to avoid erratic behavior. A terminator is a 90-120
ohm 1/4 watt resistor which is connected between pins 2 and 3 of a male XLR
connector (DATA + and DATA -). This fixture is inserted in the female XLR connector of
the last fixture in your daisy chain to terminate the line. Using a cable terminator
(Elation part number Z-DMX/T) will decrease the possibilities of erratic behavior.
Loading...
+ 44 hidden pages