Elation Opti Tri White Par User Instructions

Page 1
Opti Tri White Par
Opti Tri White Par Introduction
Unpacking: Thank you for purchasing the Opti Tri White Par by Ela-
tion Professional®. Every Opti Tri White Par has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during ship­ping. If the carton appears to be damaged, carefully inspect your x­ture for any damage and be sure all accessories necessary to operate the unit has arrived intact. In the case damage has been found or parts are missing, please contact our customer support number for further instructions. Do not return this unit to your dealer without rst contact­ing customer support.
Introduction: The Opti Tri White Par is part of Elation Profession-
als® continuing pursuit for creating high quality affordable intelligent
fixtures. The Opti Tri White Par is a powerful DMX intelligent LED wash.
This wash is light weight and compact which makes it a great piece for mobile DJ’s and clubs. This unit can be used as a stand alone unit, or
in a master/slave conguration. The unit can run in sound active mode, Auto mode, or be controlled via DMX controller.
Customer Support: ©Elation® provides a customer support line, to
provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.elationlighting.com for any comments or sugges­tions. Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m.
Pacic Standard Time.
Voice: (323) 582-3322
Fax: (323) 582-3108
E-mail: support@elationlighting.com
8/11
User Instructions
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures war­ranty. In the unlikely event your unit may require service please contact
©Elation customer support.
PLEASE recycle the shipping carton when ever possible.
Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 2
Page 2
Opti Tri White Par General Instructions
Opti Tri White Par Safety Precautions
To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
Opti Tri White Par Features
• Dual Yoke for Floor Mounting
• DMX-512 protocol
• 2 DMX Channel Modes: 3 Channel mode & 6 Channel Mode
• Dimming 0-100%
• 3 and 5 Pin DMX Inputs and Outputs
• Tri White Technology: Cool, Warm, & Amber
• Built-In Microphone for Sound Active Mode
• 13 Preset Color Temperatures (Macros)
• Strobing
Opti Tri White Par Warranty Registration
The Opti Tri White Par carries a two year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper included in the shipping carton. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by contacting our customer support team on our customer support number. All pack­ages returned to the service department not displaying a R.A. number on the outside of the package will be returned to the shipper.
• To reduce the risk of electrical shock or re, do not expose this unit
rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt to remove or break o the ground
prong from the electrical cord. This prong is used to reduce the risk
of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user
serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Never plug this unit in to a dimmer pack
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product out`
doors voids all warranties.
• During long periods of non-use, disconnect the unit’s main power.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to
be walked on or pinched by items placed upon or against them,
paying particular attention to the point they exit from the unit.
• Cleaning -The fixture should be cleaned only as recommended by t he manufacturer. See page 12 for cleaning details.
• Heat -The appliance should be situated away from heat sources
such as radiators, heat registers, stoves, or other appliances (inclu­ d ing amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged. B. Objects have fallen, or liquid has been spilled into the appliance.
C. The appliance has been exposed to rain or water. D. The appliance does not appear to operate normally or exhibits a
marked change in performance.
Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 4Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 3
Page 3
Opti Tri White Par Set Up
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
Opti Tri White Par Set Up
Power Supply: The Elation Opti Tri White Par contains an automatic voltage switch, which will auto sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the correct power voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that trav­els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter­minals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX compli­ant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation):
The Opti Tri White Par can be controlled via DMX-512 protocol. The Opti Tri White Par has 2 DMX Channel Modes; 3 Channel mode and 6 Channel mode. Your unit and your DMX controller require a approved DMX-512 110 Ohm Data cable for data input and data output. We rec­ommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded
cable (This cable may be purchased at almost all professional sound and lighting stores). Your cables should be made with a male and female
XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained
and cannot be split.
Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 5
Figure 1
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con­nect the cable’s shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR’s outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
1
2
XLR Male Socket
1 Ground
Figure 3
DMX512 OUT
3-PIN XLR
2 Cold
3 Hot
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con­nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
5-Pin XLR DMX Connectors.
512 data cables for DATA transmission in place of 3-pin. 5-pin DMX xtures may be implemented in a 3-pin DMX line. When inserting stan-
dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 6
3
XLR Female Socket
2 Cold
COMMON
DMX +
DMX -
3
1
2
DMX512 IN
3-PIN XLR
Figure 2
XLR Pin Conguration
1 Ground
3 Hot
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
When longer runs of cable are
Figure 4
Some manufactures use 5-pin DMX-
Pin 1
Pin 2
Pin 3
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use
Page 4
Opti Tri White Par Operating Instructions
Opti Tri White Par Operating Instructions
LED Display On/Off:
To set the display light to turn off after 10 seconds, press the MODE button until DispPerm is displayed. Using the Now the display will blackout after 10s. Press any button to turn the display on again. Be
advised though that the display will turn off automatically after 10 seconds.
To set the display press the MODE button until DispPerm XX is dis­played. “XX” represents either ON or OFF. DispPerm ON = LCD display light is on at all times. DispPerm Off = LCD display light shuts off after 10 seconds.
Operating Modes:
• Sound-Active mode - In this mode the unit will react to sound.
• Macro Mode (Preset Color Temperatures) - There are 13 macros
(preset color temperatures) macros to choose from.
• DMX control mode - This function will allow you to control each individual fixtures traits with a standard DMX 512 controller such as
as the Elation® Show Designer™.
Master-Slave Operation:
This function will allows you to link units together to run in a Master­Slave mode. In Master-Slave operation one unit will act as the con­trolling unit and the others will react to the controlling units built-in programs. Any unit can act as a Master or as a Slave however, only
one unit can be programmed to act as the “Master.”
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the unit. Use standard XLR data cables to link your units together. Remember that the Male XLR connector is the input and the Female XLR connector is the ouput. The first unit in the chain (master) will use the female XLR connector only. The last unit in the chain will use the male XLR connector only.
2. Set the “Master” unit to your desired mode of operation.
3. For the “Slave” unit(s), set the display to DMX address 1.
4. Connect the “Slave” unit or units and they will automatically start to follow the “Master.”
Sound Active Mode:
In this mode the Opti Tri White Par will react to sound.
1. Plug the fixture in and press the MODE button until “SoundCtl
Color” is displayed. The unit will now react to the beat of the music.
Dimmer Mode:
1. Plug the fixture in and press the MODE button until:
2. When “ColorSet Cool X” is displayed you are in Cool White dim­ ming mode. Press the UP and DOWN buttons to adjust intensity.
3. When “ColorSet Warm X” is displayed you are in Warm White dimming mode. Press the UP and DOWN buttons to adjust inten-
sity.
4. When “ColorSet Amber X” is displayed you are in Amber dimming mode. Press the UP and DOWN buttons to adjust intensity.
5. To return to previous dimming modes you must press the MODE button until that mode is displayed again. Continue to make adjustments until your desired color output/temperature is reached.
6. You can use the chart on page 10 to adjust the dimmer’s to cer-
tain color temperatures.
Macro Mode (Preset Color Temperature):
In this mode you are able to choose one of 13 macros (preset color
temperatures).
1. Plug the fixture in and press the MODE button until “MacroSet Mode X” is displayed. “X” represents the current macro number
that is displayed. Each macro is a preset color temperature that is
set at the factory. There are 13 color temperatures to choose from.
2. Use the UP and DOWN buttons to find your desired preset macro. See the chart on page 10 for the list of macros and the color tem-
perature it represents.
Strobe Mode:
In this mode you can activate the strobe. The strobe mode will only work in conjunctions with the Dimmer mode.
1. First adjust the Cool White, Warm White, and Amber so that your
desired output color is reached.
2. Press the MODE button until “ColStrob Speed XX” is displayed.
Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 8Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 7
Page 5
Opti Tri White Par Operating Instructions Opti Tri White Par Macro Preset Temperatures
OPTI TRI WHITE
Photometric Beam Angle Data Standard 20° Beam Angle
LUX x 0.0929
= FC
“XX” reprents the strobe speed.
3. Use the UP or DOWN buttons to adjust the strobe speed. “1” is the slowest speed, “20” the fastest speed.
Note. If the Warm White, Cold White, and Amber dimmer modes are all set to “0”, there will be no light output in this mode.
Fade Mode:
In this mode you can activate the auto fade. The fade mode will only work in conjunctions with the Dimmer mode.
1. First adjust the Cool White, Warm White, and Amber so that your
desired output color is reached.
2. Press the MODE button until “ColProgr Speed XX” is displayed. “XX” reprents the fade speed.
3. Use the UP or DOWN buttons to adjust the fade speed. “1” is the slowest speed, “16” the fastest speed.
Note. If the Warm White, Cold White, and Amber dimmer modes are all set to “0”, there will be no light output in this mode.
DMX Mode:
Operating through a DMX controller gives the user the freedom to create their own programs tailored to their own individual needs. The
Opti Tri White Par has two DMX Channel Modes; 3 Channel mode & 6
Channel mode.
1. This function will allow you to control each individual fixture’s traits with a standard DMX 512 controller.
2. To run your fixture in DMX mode, you must first select which DMX
Channel mode you want to use.
3. To select 3 Channel mode, press the MODE button until “DMX­ 3CH DMX X” is displayed. “X” represents the current displayed address. Select your desired DMX address using the UP or DOWN buttons.
4. To select 6 Channel mode, press the MODE button until
“DMX-6CH DMX X” is displayed. “X” represents the current dis­ played address. Select your desired DMX address using the UP or DOWN buttons.
5. Once you have chose your desired DMX channel mode and set the DMX address plug in the fixture via the XLR connections to any standard DMX controller.
6. Please see page 11 for DMX values and traits.
MODE Color
CW WW AMBER
Temperature(k)
1
2
3
4
5
6
7
8
9
10
11
12
13
Opti Tri White Par Macro Preset Temperatures
495 FC / 5333 LUX
CW
353 FC / 3797 LUX
WW
185 FC / 1991 LUX
A
949 FC / 10210 LUX
ALL
0 m
0 ft
Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 10Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 9
1 m
3.2 ft
132 FC / 1407 LUX
85 FC / 913 LUX
50 FC /543 LUX
259 FC / 2789 LUX
2 m
6.6 ft
58 FC / 622 LUX
39 FC / 416 LUX
23 FC / 246 LUX
117 FC / 1263 LUX
3 m
9.8 ft
35 FC / 379 LUX
23 FC / 248 LUX
14 FC / 147 LUX
69 FC / 742 LUX
4 m
13.1 ft
24 FC /255 LUX
15 FC / 166 LUX
9 FC / 99 LUX
74 FC / 798 LUX
5 m
16.4 ft
20° Beam Angle
Page 6
Opti Tri White Par 3 Channel Mode
Opti Tri White Par Fuse Replacement
Channel Value Function
1 0 - 255 COOL WHITE 0% - 100%
2 0 - 255 WARM WHITE 0% - 100% 3 0 - 255 AMBER 0% - 100%
Opti Tri White Par 6 Channel Mode
Channel Value Function
1 0 - 255 COOL WHITE 0% - 100%
2 0 - 255 WARM WHITE 0% - 100% 3 0 - 255 AMBER 0% - 100% 4 MACROS (COLOR TEMPERATURES)
0 - 18 OFF 19 - 37 MACRO 1 (6000k)
38 - 56 MACRO 2 (5700k) 57 - 75 MACRO 3 (5400k)
76 - 94 MACRO 4 (5100k) 95 - 113 MACRO 5 (4800k) 114 - 132 MACRO 6 (4500k) 133 - 151 MACRO 7 (4200k) 152 - 170 MACRO 8 (3900k) 171 - 189 MACRO 9 (3600k) 190 - 208 MACRO 10 (3300k) 209 - 227 MACRO 11 (3000k) 228 - 246 MACRO 12 (2700k) 247 - 255 MACRO 13 (2400k)
5 0 - 255 STROBING SLOW - FAST 6 0 - 255 MASTER DIMMER 0% - 100%
Disconnect from the main power supply. Insert a standard flat head screw driver in to the fuse holder housing, located on the back of the unit. Turn the screwdriver in counter-clockwise direction to remove the fuse holder. Remove the old fuse and discard it, replace the fuse with the same type. Insert the fuse back into it’s housing.
Opti Tri White Par Cleaning
Due to fog residue, smoke, and dust cleaning the internal and exter­nal optical lenses must be carried out periodically to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the
outside casing.
2. Clean the external optics with glass cleaner and a soft cloth
every 20 days.
3. Always be sure to dry all parts completely before plugging the unit back in.
Cleaning frequency depends on the environment in which the fixture
operates (i.e. smoke, fog residue, dust, dew).
Opti Tri White Par Trouble Shooting
Listed below are a few common problems the user may encounter,
with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are wired correctly (pin 3 is “hot”; on some other DMX devices
pin 2 may be ‘hot’). Also, check that all cables are connected
to the right connectors; it does matter which way the inputs
and outputs are connected.
Unit does not respond to sound:
1. Quiet or high pitched sounds will not activate the unit.
Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 11
Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 12
Page 7
Opti Tri White Par Warranty
2-YEAR LIMITED WARRANTY
A. Elation Professionals® hereby warrants, to the original purchaser, Elation Profes­sionals® products to be free of manufacturing defects in material and workmanship for a period of two years (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States of America, including
possessions and territories. It is the owner’s responsibility to establish the date and
place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service, send the product only to the Elation Professionals® factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professionals® will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professionals® shall have no liability whatsoever for loss of or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the prod-
uct is modied in any manner which Elation Professionals® concludes, after inspec-
tion, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professionals® factory unless prior written authori­zation was issued to purchaser by Elation Professionals®; if the product is damaged because not properly maintained as set forth in the instruction manual.
D. This is not a service contract, and this warranty does not include maintenance, cleaning or periodic check-up. During the period specied above, Elation Profession­als® will replace defective parts at its expense, and will absorb all expenses for war­ranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professionals® under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professionals®. All products covered by this warranty were manufactured after January 1, 1990, and bear identifying marks to that effect.
Opti Tri White Par Notes
E. Elation Professionals® reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professionals® in connec-
tion with this product, including warranties of merchantability or tness, are limited in
duration to the warranty period set forth above. And no warranties, whether expressed
or implied, including warranties of merchantability or tness, shall apply to this prod­uct after said period has expired. The consumer’s and or Dealer’s sole remedy shall
be such repair or replacement as is expressly provided above; and under no circum­stances shall Elation Professionals® be liable for any loss or damage, direct or conse­quential, arising out of the use of, or inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professionals® Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 13 Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 14
Page 8
Opti Tri White Par Specifications
Model:
SPECIFICATIONS:
Working Position: Any safe working position
Voltage: 100V ~ 240V/47~63Hz LED’s: 54 x 3 Watt Power Consumption: 160W Max
Fuse: 2A Beam Angle: 20 Degrees
Weight: 10.5lbs./ 4.8Kgs. Dimensions: 11” (L) x 8.6” (W) x 14” (H) Colors: Warm White, Cool White, & Amber DMX Channels: 2 DMX Modes: 3 Channel Mode &
6 Channel Mode Warranty: 2 Year (730 days)
Auto Sensing Voltage: This xture contains a automatic voltage switch, which will auto sense the voltage when it is plugged into the power source.
Please Note: Specications and improvements in the design of
this unit and this manual are subject to change without any prior written notice.
Opti Tri White Par
Elation Professional - www.elationlighting.com - Opti Tri White Par Instruction Manual Page 15
©Elation Professionals®
A Division of the AmericanDJ® Group of Companies
World Headquarters:
6122 S. Eastern Ave. Los Angeles, CA 90040 USA
Tel: 323-582-3322 Fax: 323-582-3311
Web: www.elationlighting.com E-mail: info@elationlighting.com
American DJ Europe
Junostraat 2
6468 EW Kerkrade
Netherlands
service@adjgroup.eu / www.americandj.eu
Tel: +31 45 546 85 00 / Fax: +31 45 546 85 99
Loading...