USER MANUAL FOR LWP-48 RGB DMX
Important
Damages caused by the disregard of this user manual or unauthorized
modification to products are not subject to warranty.
Please make sure that there are no obvious transport damages.
Please immediately contact the local dealers as the fixture is in fault
operation or damage.
Always plug in the power plug last. The power plug must always be
inserted with force. Make sure the plug is tightly connected with outlet.
If extension cords are used make sure that the core diameter is sufficient
for required power consumption of the device. All warnings concerning the
power cords are also valid for possible extension cords.
Do not block any of ventilation openings.
Do not open the fixture and try to repair the fixture personally.
1. SAFETY INSTRUCTION
Every person involved with installation and maintenance of the this device has
to :
-be qualified.
-following the instructions of manual
This device has left our premises in absolutely perfect condition. In order to
maintain this condition and to ensure a safe operation, it is absolutely necessary
for the user to follow the safety instructions and warming note written in this
manual.
CAUTION!
Keep th is dri ver away fo rm rain and moistu re
Unplug mains lead befo re opening th e housing
Read the instructions care fully before you install start-up!
CAUTION!
Be careful with your operatio ns.
You can suffer a dangerous electric shock when touch the wires ins ide
the unit.
ELATION LWP48 R GB DMX
www.elationlighting .eu
User manu al
Page 1 of 5

Description of LWP-48 RGB DMX
2. OPERATION DETERMINATIONS
The device must only be used indoor.
If the unit has been exposed to drastic temperature, do not switch it on
immediately. The arising condensation water might damage your unit.
Leave the unit switched off it has reached room temperature.
Only operate the unit after having checked the housing is firmly closed
and all screws tightly fastened. Do not shake the device. Avoid brute
force when installing or operation the device.
Operate the device only after having familiarized with its functions. Do
not permit operation by persons not qualified for operating the device.
Most damages are the result of unprofessional operation!
The maximum ambient temperature 40 degree must never be exceeded.
Please consider that unauthorized modifications on the device are
forbidden due to safety reasons!
3 PinX LR DMX connec tor
Safety ri ng
AC inp ut
100~ 24 0V
50/6 0H z
DMX setti ng
ELATION LWP48 R GB DMX
www.elationlighting .eu
User manu al
Page 2 of 5

Unplug form the mains before installation
Fix the fixture with bracket
Connect the AC power cord to the socket
4. SIGNAL INDICATORS
Receive DMX signal: the green light emitting diode shows when the lighting
fixtures receive DMX signal.
Receive Master signal: the green light emitting diode shows when the lighting
fixture are set Master
3. INSTALLATION
AC in put
100~240V
50/60Hz
DMX IN/OUT
3 PIN XLR
AC in put
100~240V
50/60Hz
ELATION LWP48 R GB DMX
www.elationlighting .eu
User manu al
Page 3 of 5

2. Fixed color
Fixed color: there are 20 built-in fixed colors in the CD-65II
Press Menu. The display shows C01
Press up and down to select the desired color from C01~C20
3. Fade program
Fade program: there are 9 built-in fade programs in the CD-65II
Press Menu. the display shows F01
Press up and down to select the desired program from F01~F09
The fade time of program can be changed from 01~99%(0.5~50sec).
E.g:F03 is running. The fade time can be change by press menu
and hold for 3 sec.The display will show S---- The fade time can
be adjusted to 01~99%.by press Up and down and press Menu again
to confirm.
4. DMX Mode setting
The following mode can be selected by press menu to confirm it.
Press Menu. the display shows S---
Press up and down to select the desired program from S01~S41
Press menu again to confirm it.
S10: Control all of LED fixtures in the same channel (default).
S11: Control all of LED fixtures independently
S20: Master off (default).
S21: Master
S30: RGB 3 channels (default).
S31: RGB dimming, strobe 5 channels
S40: Delay off (default).
S41: Delay on
NOTE: the f unction of d elay on is designed f or running s low, and free-fliker progr am.
The respo nse speed of L EDs is slowe r than normal. All d rivers mus t be set on the sa me
mode( del ay on or off) as c onnecting together ,other wise, the pr ogram does n ot run
synchro nously.
The slave d rivers mus t be set add. 00 1 when running Mast er/Slave f unction.
1.DMX add. Setting
5. OPERATION
001001
C01C01
F01F01
S-S-
Me n u
Ad d .
Co l o r
Fa d e
Se t
--
Men uMen u
UpUp
Dow nDow n
DMX Address: press Menu. the display shows the initial DMX
address.
Press up and down to select the desired address from 001-512
ELATION LWP48 R GB DMX
www.elationlighting .eu
User manu al
Page 4 of 5

Electrical:
Power requirement: 100-240VAC, 50-60HZ
Meets CE safety standards
Power consumption: 48W at full intensity
Source & Optics:
LEDs: 16 x 1W Red/ 16 x 1WGreen/ 16 x 1W Blue
Lens Beam Angle: Standard 25 degree
Life time: estimated 100,000 hours when color changing
Total Lux (3M): R580 G 960 B55 W1150
Communication:
DMX512(1990): RGB 3 channels
Operating temperature
-10~40 degree
Dimension(mm): L1071 x W 60.6 x H 35.9
Weight: 4Kg
Protection: Ip20
6. Technical Specifications of Lighting Fixtures