GENERAL INFORMATION ON WATER BLOCK COMPATIBILITY
This CPU liquid cooling unit is pre-assembled for use with modern Intel desktop socket type mother­boards. By default (out of the box) this water block supports the follow­ing CPU sockets:
- Intel® Socket LGA-115x
- Intel® Socket LGA-2011(-3)
This product is also fully compatible with Intel® LGA-775, LGA-1366 and AMD® AMx/FMx sockets however the required backplates and/or AMD mounting plate is not included in the box. The aforementioned parts are avail­able free of charge from EK Webshop and Partner Reseller Network.
/ 4 /
- EK-Supremacy EVO universal CPU water block.
- PreciseMount EVO universal CPU mounting mechanism:
• M4 threaded thumb screws (4 pcs)
• LGA-2011 M4 threaded mounting studs (4 pcs)
• Springs (4 pcs)
• M4 threaded thumb nuts (4 pcs)
• Washers (4 pcs)
- EK-Supremacy Backplate
• Backplate rubber gasket
• Backplate for Intel® LGA-115x socket motherboards
- Allen (hex) key 2.5mm
- Additional Inserts and Jet plates:
• Jet J2 (0.3mm thick)
• Jet J3 (0.1mm thick)
• Insert I2
- Thermal grease
The following items are enclosed with each EK-Supremacy EVO water block:
Narrow server type LGA-2011 is not supported by default – a Mounting plate Supremacy LGA-2011 Narrow ILM (EAN: 3830046990600) is mandatory to install this water block on narrow server type LGA-2011 motherboards. Re­placing the mounting plate requires disassembly of the water block.
WHAT IS ENCLOSED
/ 5 /
STEP 1
Please observe the table below to determine the optimal combina­tion of insert and jet plate for your type of socket:
Socket Optimal
Insert
Optimal
Jet
AMD® AMx / FMx
I2 J2
LGA-775 I1 J2
LGA-115x I1 J2
LGA-1366 I1 J1
LGA-2011 I1 J1
LGA-2011(-3) I2 J3
STEP 1
I1 J1
d=0,25 mmJ2d=0,30 mmJ3d= 0,10 m m
REPLACING THE JET PLATE /INSERT PROCEDURE (OPTIONAL)
I2
Water block top
Insert pin Insert Jet plate
Gasket
Mounting plate
Copper base Screws
/ 6 /
STEP 2
Unscrew the four M4 screws in counter-clock­wise direction from the bottom of the water block using enclosed 2,5mm Allen key to re­lease the assembly, consisting of water block top, the insert, insert pin and jet plate. Upon re­placing the insert and/or jet plate please re-as­semble the water block as shown on the photo in STEP 1 and STEP 2. Pay special attention to the insert orientation relative to the copper base and water block top!
Before re-assembly of the water block it is crucial that the pre-formed gasket (o-ring) is placed into the gap between the mounting plate and the water block top.
Screw the four screws back in but don’t exag­gerate with the force applied.
STEP 2
Insert pin
Insert pin
Jet plate
Insert
Insert