Supremacy EVO
7th revision, Mar 4th 2016
USER GUIDE

/ 3 /
GENERAL INFORMATION ON WATER BLOCK COMPATIBILITY
This CPU liquid cooling unit is
pre-assembled for use with modern
Intel desktop socket type motherboards. By default (out of the box)
this water block supports the following CPU sockets:
- Intel® Socket LGA-115x
- Intel® Socket LGA-2011(-3)
This product is also fully compatible with Intel® LGA-775, LGA-1366 and
AMD® AMx/FMx sockets however the required backplates and/or AMD
mounting plate is not included in the box. The aforementioned parts are available free of charge from EK Webshop and Partner Reseller Network.

/ 4 /
- EK-Supremacy EVO universal CPU
water block.
- PreciseMount EVO universal CPU
mounting mechanism:
• M4 threaded thumb screws (4 pcs)
• LGA-2011 M4 threaded mounting
studs (4 pcs)
• Springs (4 pcs)
• M4 threaded thumb nuts (4 pcs)
• Washers (4 pcs)
- EK-Supremacy Backplate
• Backplate rubber gasket
• Backplate for Intel® LGA-115x
socket motherboards
- Allen (hex) key 2.5mm
- Additional Inserts and Jet plates:
• Jet J2 (0.3mm thick)
• Jet J3 (0.1mm thick)
• Insert I2
- Thermal grease
The following items are enclosed with each EK-Supremacy EVO water block:
Narrow server type LGA-2011 is not supported by default – a Mounting plate
Supremacy LGA-2011 Narrow ILM (EAN: 3830046990600) is mandatory
to install this water block on narrow server type LGA-2011 motherboards. Replacing the mounting plate requires disassembly of the water block.
WHAT IS ENCLOSED

/ 5 /
STEP 1
Please observe the table below to
determine the optimal combination of insert and jet plate for your
type of socket:
Socket Optimal
Insert
Optimal
Jet
AMD®
AMx / FMx
I2 J2
LGA-775 I1 J2
LGA-115x I1 J2
LGA-1366 I1 J1
LGA-2011 I1 J1
LGA-2011(-3) I2 J3
STEP 1
I1 J1
d=0,25 mmJ2d=0,30 mmJ3d= 0,10 m m
REPLACING THE JET PLATE /INSERT PROCEDURE (OPTIONAL)
I2
Water block top
Insert pin
Insert
Jet plate
Gasket
Mounting plate
Copper base
Screws

/ 6 /
STEP 2
Unscrew the four M4 screws in counter-clockwise direction from the bottom of the water
block using enclosed 2,5mm Allen key to release the assembly, consisting of water block
top, the insert, insert pin and jet plate. Upon replacing the insert and/or jet plate please re-assemble the water block as shown on the photo
in STEP 1 and STEP 2. Pay special attention
to the insert orientation relative to the copper
base and water block top!
Before re-assembly of the water
block it is crucial that the pre-formed
gasket (o-ring) is placed into the
gap between the mounting plate
and the water block top.
Screw the four screws back in but don’t exaggerate with the force applied.
STEP 2
Insert pin
Insert pin
Jet plate
Insert
Insert