EKWB ek-mlc phoenix Installation manual

For EK-MLC Phoenix series units | 1st revision, 2017
Pre-filled Modular Liquid Cooling
EK-MLC PHOENIX
USER GUIDE
EK Water Blocks bears the name of its founder Edvard König, who started experimenting with liquid cooling in 1999. From the humble beginnings in the early years of the previous decade, the company grew steadily to become a global premium liquid cooling gear manufacturer. Today, EKWB offers a complete range of products for liquid cooling, from a renowned Supremacy line of CPU water blocks, to a wide range of CoolStream radiators, from in-house developed Vardar High pressure fans, to market-proven DDC and SPC series of liquid cooling pumps and thus provides overclocking enthusiasts and PC builders with the best of what the market can offer. Phoenix all-in-one Modular Liquid Cooling solution is the next step to bring extreme liquid cooling performance in the hands of dedicated gamers and PC enthusiasts around the world.
Welcome to EK-World!
Safety precautions
1. Keep and store the product away from the reach of children.
2. Check the component list and condition of the product before installation. If there is any problem, contact the shop where you have purchased the product to get a replacement or refund.
3. EKWB d.o.o. is not responsible for any damages due to external causes, including but not limited to, improper use, problems with electrical power, accident, neglect, alteration, repair, improper installation and improper testing.
4. CPU, GPU and motherboard are subject to damage if the products are incorrectly installed.
5. This product is All-In-One Modular liquid cooling solution. Disassembling it and combining with parts, other than EK Water Blocks products, may lead to warranty loss.
6. Product warrant y period is 24 months.
/ 1 /
TABLE OF CONTENT
SCOPE OF DELIVERY 3 REQUIRED TOOLS 3 VIDEO INSTALLATION GUIDES 3
QUICK INSTALLATION GUIDE
RADIATOR SPACE CONSTR AINT REQUIREMENTS 4
EK-MLC PHOENIX 120 4 EK-MLC PHOENIX 240 5 EK-MLC PHOENIX 360 6 EK-MLC PHOENIX 140 7 EK-MLC PHOENIX 280 8
UNIT ORIENTATION LIMITATIONS 9 EK-MLC PHOENIX QDC CONNECTIONS GUIDE 10 ELECTRICAL CONNECTIONS 10
CONNECTING THE HUB TO THE POWER SUPLY 10 CONNEECTING THE HUB TO THE MOTHERBOARD 10
REMOVING THE EXPANSION BALLOON 11 INSTALLING THE PUMP/FAN/RADIATOR UNIT 12 INSTALLING THE COOLING MODULES 13
GENERAL INFORMATION ON WATERBLOCK COMPATIBILITY 14 INSTALLING THE CPU COOLING MODULE 15
LGA-2011(-3) SOCKET MOTHERBOARDS 15 LGA-115X SOCKE T MOTHERBOARDS 16 AM4 SOCKET MOTHERBOARDS 19
CONNECTING THE LED 22 CONNECTING THE MODULES WITH QDC 22 MAINTENANCE 25 FREQUENTLY ASKED QUESTIONS 25 TROUBLESHOOTING 28
IN CASE OF CPU OVERHEATING 28 THE COOLER IS TOO LOUD 29
GENERAL LIQUID COOLING PARTS CLEANING GUIDE 29
PREVENTIVE STEPS 30
PART SPECIFIC ATION LIST 31
PUMP 31 FAN SPLITTER HUB 31 FANS 33 THERMAL GREASE 33 TUBING 33
SUPPORT AND SERVICE 34 SOCIAL MEDIA 34
/ 2 /
SCOPE OF DELIVERY
RAD unit CPU unit GPU unit
All-in-one expandable liquid cooling unit
EK-MLC Phoenix (incl. QDC)
120 240 360
140 280
Installation manual
REQUIRED TOOLS
Phillips-head screwdriver
CPU liquid cooling unit
CPU Mounting mechanism
CPU
Backplate
mechanism
Thermal
grease
GPU liquid cooling unit
GPU Mounting
mechanism
VIDEO INSTALLATION GUIDES
Our official YouTube channel features video installation guides, that can help you with Phoenix installation. Scan the QR code to visit our YouTube channel.
Thermal
grease
/ 3 /
RADIATOR SPACE CONSTRAINT REQUIREMENTS
EK-MLC PHOENIX 120
/ 4 /
133 mm (5,24 in)
120 mm (4,72 in)
17 7 mm (6,97 in)
68 mm (2,68 in)
Radiator
Pump
EK-MLC PHOENIX 240
133 mm (5,24 in)
120 mm (4,72 in)
15 mm (0,59 in)
295 mm (11,61 in)
68 mm (2,68 in)
Radiator
Pump
/ 5 /
EK-MLC PHOENIX 360
Pump
415 mm (16,34 in)
15 mm (0,59 in)
133 mm (5,24 in)
120 mm (4,72 in)
68 mm (2,68 in)
Radiator
/ 6 /
EK-MLC PHOENIX 140
142 mm (5,59 in)
140 mm (5,51 in)
195 mm (7,68 in)
68 mm (2,68 in)
Radiator
Pump
/ 7 /
EK-MLC PHOENIX 280
142 mm (5,59 in)
140 mm (5,51 in)
15 mm (0,59 in)
335 mm (13,19 in)
68 mm (2,68 in)
Radiator
/ 8 /
Pump
CAUTION:
The orientation of the unit is very important, as wrong installation may lead to insufficient cooling performance and premature failure of the unit.
Pump
Pump
UNIT ORIENTATION LIMITATIONS
The orientation limitations stand for all versions of the Phoenix unit.