Eizo 620L User Manual

- For Administrator -
For Microsoft Windows CE.NET
Version E
Please confirm the version of the software built in eClient, and refer to the suited User's Manual (Refer to the User's Manual Version List on next page).
This is the manual for the following software version.
* Microsoft Windows CE: 4.0 Rev. 2.3.2 or later * Microsoft Terminal Server Client: Ver. 7.2.1 or later * ICA Client: Ver. 7.23 or later

User’s Manual Version List

A handling description changes with versions of the software built in eClient. Please refer to below.
NOTE
The version of software built in eClient can be checked with a [System]-[ICA] tab of
[Terminal Properties].
OS: Microsoft Windows CE .NET
Software
Manual
E
(This Manual)
D 4.0 Rev.2.3.0 or later Version 7.2.0 or later Version 7.23 or later
C 4.0 Rev.2.2.0 or later Version 7.1.0 or later
B 4.0 Rev.2.1.1 or later Version 7.0.2 or later
A 4.0 Rev.2.0.0 or later Version 7.0.0 or later
Microsoft Windows CE
4.0 Rev.2.3.2 or later Version 7.2.1 or later Version 7.23 or later
Microsoft Windows
Terminal Server
[Build1078D] or later
[Build1063] or later
[Build1056] or later
ICA Client
Software
Version 6.30
Version 6.30
Version 6.30

SAFETY SYMBOLS

This manual uses the safety symbols below. They denote critical information. Please read them carefully.
WARNING
Failure to abide by the information in a WARNING may result in serious injury and can be life threatening.
CAUTION
Failure to abide by the information in a CAUTION may result in moderate injury and/or property or product damage.
Indicates a prohibited action.
Indicates to ground for safety.
Copyright© 2003-2004 EIZO NANAO CORPORATION All rights reserved. No part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, or otherwise, without the prior written permission of Eizo Nanao Corporation. EIZO NANAO CORPORATION is under no obligation to hold any submitted material or information confidential unless prior arrangements are made pursuant to EIZO NANAO CORPORATION's receipt of said information. Although every effort has been made to ensure that this manual provides up-to-date information, please note that EIZO monitor specifications are subject to change without notice.
ENERGY STAR is a U.S. registered mark. Microsoft, Windows, Windows NT, the Windows logo are registered trademarks of Microsoft Corporation. Citrix, Independent Computing Architecture (ICA), and MetaFrame are registered trademarks or trademarks of Citrix Systems, Inc. in the U.S.A. and other countries. BSQUARE is a registered trademark of BSQUARE Corporation. JEM-CE is a trademark of BSQUARE Corporation. EIZO and eClient are registered trademarks of EIZO NANAO CORPORATION.
As an ENERGY STAR that this product meets the ENERGY STAR guidelines for energy efficiency.
®
Partner, EIZO NANAO CORPORATION has determined

TABLE OF CONTENTS

1. INTRODUCTION ..................................................................................... 5
1-1. General Description ......................................................................................5
1-2. Features ........................................................................................................5
1-3. Package Contents..........................................................................................6
1-4. Controls & Connectors ................................................................................7
2. CONNECTING THE eClient 620L .......................................................... 9
2-1. Setting up the eClient 620L...........................................................................9
2-2. Connecting the eClient 620L ......................................................................10
3. SETTING UP the eClient 620L ............................................................ 11
4. ADDING & CHANGING A CONNECTION NAME ................................ 19
4-1. Adding a Connection Name........................................................................19
4-2. Setting an Autostart Connection.................................................................22
4-3. Modifying a Connection Name...................................................................22
5. LOGON & LOGOFF.............................................................................. 23
5-1. Logon to a WTS / Logoff from a WTS........................................................23
5-2. Opening/Closing a Local Web Browser.......................................................27
6. USING THE TERMINAL PROPERTIES ................................................ 29
6-1. General .......................................................................................................31
6-2. Local Resources (RDP protocol only) .........................................................32
6-3. Display........................................................................................................33
6-4. Experience (RDP protocol only) .................................................................35
6-5. Control Panel..............................................................................................36
6-6. ICA Settings (ICA Protocol only)................................................................44
6-7. Server..........................................................................................................45
6-8. Security .......................................................................................................46
6-9. System.........................................................................................................48
7. SOFTWARE UPDATING/INSTALLATION ............................................ 49
8. PRACTICAL SETUP............................................................................. 53
8-1. 620L settings...............................................................................................53
8-2. Short cut command by keyboard ................................................................56
9. TROUBLESHOOTING........................................................................... 57
10. CLEANING.......................................................................................... 58
11. SPECIFICATIONS............................................................................... 59
12. REFERENCE ...................................................................................... 61
12-1. Attaching an Arm Stand ...........................................................................61
INDEX ....................................................................................................... 62
4 TABLE OF CONTENTS
4

1. INTRODUCTION

Thank you very much for purchasing the EIZO eClient 620L.

1-1. General Description

The eClient 620L connects with a Windows Terminal Server*, which installed Microsoft Windows NT Server 4.0 Terminal Server Edition or Windows 2000 Server/Advanced Server/Datacenter Server, and this product is used as a terminal using them.
Windows Terminal Server (WTS)
Output data of
applications
Input data from
mouse/keyboard
eClient 620L
· Operation of applications
· Storage of data
- * Windows Terminal Server expresses ‘WTS’ hereafter.

1-2. Features

Lower TCO (Total Cost of Ownership)
Saves Space and Power Consumption
Less Heat, Less Noise
Speakers equipped
Serial Port for Modem/PDA
Local Web Browser added as a default connection 620L
Wake on LAN supported
The portrait display capability
· Display data
· Operation by mouse/keyboard
1. INTRODUCTION 5

1-3. Package Contents

Please make sure that all the items listed are in the package. Please contact your local dealer for assistance if any of the listed items are missing or damaged.
eClient 620L
Mouse (FDM-L30S)
Power Cord
Screw (M4 x 12 mm) x 4
User’s Manual (includes Limited Warranty)
2 Stickers of the Brightness Control Guide
NOTE
A keyboard is not included. Please purchase a USB keyboard separately.
[The keyboards, which have been confirmed working without problem, are as follows.]
- Microsoft Internet Keyboard Pro (Japanese)
- Microsoft Natural Keyboard Pro (Japanese)
- Microsoft Office Keyboard (Japanese)
Please use the enclosed mouse. EIZO NANAO CORPORATION will not be held responsible for accident or damage caused by the use of a mouse manufactured by other companies.
Please retain the packing materials for future transference.
Brightness can be adjusted by using key combinations on the keyboard (see page
34). Key combinations for an adjustment are presented on the stickers. Please apply them for your convenience.
6 1. INTRODUCTION

1-4. Controls & Connectors

Front
(1) (1)(2) (3)(4)
(1) Speakers (2) Volume Control (3) Power Indicator
Color 620L status Green
Yellow Power save mode Off
(4) Power button
NOTE
When turning off/on the unit, leave the unit off for a few seconds before turning it on again.
Operation
Screen saver mode
Suspend mode (Wake on LAN standby)
Power off (Wake on LAN standby)
1. INTRODUCTION 7
Rear
(12)
(11)
(13)
(6) (7)(8) (9) (10)(5)
(5) Power Connector (6) Ethernet Connector (10 Base-T, 100 Base-TX) (7) Headphone Connector (8) Microphone Connector (9) Serial Port (RS-232C) (10) USB Port (Downstream) x 2
1
(11) Security Lock* (12) Holes for Mounting an Arm Stand*
2
(13) Stand (Detachable)
1
This allows for connection of a security cable. This lock supports Kensington’s
*
MicroSaver security system. For further information, please consult: Kensington Technology Group 2855 Campus Drive, San Mateo, CA 94403 USA Tel: 800-650-4242, x3348 Intl: 650-572-2700 Fax: 650-572-9675 http://www.kensington.com
2
The LCD monitor can be used with an optional arm stand by removing the stand
*
(See p.61).
8 1. INTRODUCTION

2. CONNECTING THE eClient 620L

This chapter explains how to connect the eClient 620L to a WTS.

2-1. Setting up the eClient 620L

NOTE
Before connecting the product, set up the monitor after
unfolding the base of the stand.
WARNING
Place the eClient 620L on a strong, stable surface.
A unit placed on an inadequate surface may fall, resulting in injury or equipment damage. If the unit falls, disconnect the power immediately and have the unit checked by a qualified service engineer before using it again. Using a unit after it has been dropped may result in fire or electric shock.
Set the unit in an appropriate location.
Not doing so may result in fire, electric shock, or equipment damage.
* Do not place outdoors. * Do not place in the transportation system (ship, aircraft, trains,
automobiles, etc.)
* Do not place in a dusty or humid environment. * Do not place in a location where the steam comes directly on the
screen.
* Do not place near heat generating devices or a humidifier.
OK
2. CONNECTING THE eClient 620L
9

2-2. Connecting the eClient 620L

NOTE
Before connecting the eClient 620L, confirm the following:
- The eClient 620L is turned off.
- The WTS is turned on.
Connect the peripherals to the appropriate connectors of the unit.
1. In case of connecting the WTS through LAN:
Connect the eClient 620L to the network with an Ethernet cable.
In case of a dial-up or dial-in connection: Connect the eClient 620L to a modem or a modem card.
2. Plug a keyboard and a mouse into the eClient 620L. (Plug a mouse
into the keyboard if the keyboard has a USB port.)
3. If using other devices, please connect them to the appropriate
connectors.
4. Plug the power cord into the power connector.
WARNING
Use the enclosed power cord and connect to the standard power outlet of your country.
Be sure to remain within the rated voltage of the power cord. Not doing so may result in fire or electric shock.
The equipment must be connected to a grounded main outlet.
Not doing so may result in fire or electric shock.
10 2. CONNECTING THE eClient 620L

3. SETTING UP the eClient 620L

This chapter presents how to prepare for a connection with a WTS when the eClient 620L starts up for the first time.
1. Turn on the eClient 620L.
The power indicator turns green and a picture appears on the screen.
NOTE
When no picture is displayed, or when the message (No keyboard connected. / No mouse connected.) is shown on the screen, please refer to “8. Troubleshooting” on page 57.
2. “eClient Setup Wizard” is displayed.
(Set up the 620L according to directions of the displayed dialog box.)
3. SETTING UP the eClient 620L 11
3. End User License Agreement page is displayed.
Read the content and click [Accept] to continue.
12 3. SETTING UP the eClient 620L
4. Set up the network environment.
[Terminal Name] ................Type the name to identify this unit on the network.
Click [Network Properties] and set up connection information according to the connection method to WTS/Web server.
NOTE
In use of the dial-in connection (ICA protocol only) to log on to WTS, click [Next] to go procedure 5.
3. SETTING UP the eClient 620L 13
In case of connecting the WTS/Web through LAN:
(1) Double-click [Built-in LAN] icon
[IP Address] ........................Type the IP address of the unit.
[Name Servers]....................Type the IP address of each server when DNS or
WINS is used.
[Advanced]..........................Type the transmission speed and MAC Address of a
network.
14 3. SETTING UP the eClient 620L
In case of a dial-up connection:
(1) Double-click [Make New Connection] icon. (2) Type a name for the connection and select the connection type (Dial-Up
Connection). (3) Select a model, set up the TCP/IP settings and Security settings. (4) Type the phone number for the connection. (5) In case of a dial-up connection, the information of local location needs to be
set up. Set up the information in the later procedure 8.
NOTE
When you use VPN (Virtual Private Network), set up the connection for using
VPN further.
(1) Double-click [Make New Connection] icon. (2) Type a name for the connection and select [Virtual Private Network]. (3) Type host name or IP address and set up the TCP/IP settings and Security
settings.
Set up a Remote Connection
By setting up a Remote Connection, the WTS/Web server can be connected easily.
(6) Double-click [Make New Connection] icon. (7) Type a name for the connection and select [Remote Connection Setup]. (8) Select the desired connection from the [Available Connections] list and click
[Add] button to set in the [Current Connections]. (Connections listed in the
[Current Connections] will be executed with the listed order.) (9) Select the [Make default connection] check box. A small window will be displayed on the right bottom of the screen.
Clicking an active button of the small window starts the connection listed in
the [Current Connections].
To set an automatically start connection when the 620L boots up, select the [Connect automatically on boot up] check box.
3. SETTING UP the eClient 620L 15
5. Set up the desktop area.
[Desktop Area and Refresh Frequency]
...................................Set the resolution/refresh rate. (The 620L supports
1024 x 768 @60 Hz only). If using this product with portrait orientation, select the [Portrait display] check box.
[Desktop Colors].................Set the desktop color (256 Colors / High color) of the
following.
- Windows CE desktop (before WTS connection)
- Windows desktop (after a WTS connection with RDP protocol)
NOTE
After WTS connection, the WTS setting may control the desktop color.
16 3. SETTING UP the eClient 620L
6. Set up the browser connection.
Set up if you are setting up a web browser connection.
(1) Select [Internet Options] icon and click [Open].
[General]............................. Set up the browser.
[Connection].......................Set up the connection method to the browser.
[Security].............................Set up the security for the connection to the browser.
[Advanced]..........................Set up the display method of the browser.
7. Set up the printer.
Set up if you are using a local printer.
NOTE
The following is required to install a local printer.
- A printer is connected to the serial connector or a USB port.
- An RDP protocol is used for connection to a WTS.
- Microsoft Windows 2000 Server / Advanced Server / Datacenter Server is installed in a WTS.
(1) Select [Printer] icon and click [Open] icon. (2) Select [Add printer] icon and click [Open] icon. (3) “WTB Printer Wizard” is displayed (Follow the direction of the dialog box.).
1. Select a printer port. (Select “COM 1” for connecting to the serial connector, “LPTx” for the USB port.)
2. Select a model of your printer.
3. Name your printer.
3. SETTING UP the eClient 620L 17
8. Setup the Local sender’s setting
Setup if you are connecting to WTS/Web server by dial-up connection.
(1) Select [Dialing] icon and click [Open] icon.
[Location name]..................Choose the sender’s location (click [New] to add a
new sender’s location).
[Local Settings are:].............Setup the local settings.
9. The last page of the “eClient Setup Wizard” is displayed.
Click [Finish].
Click [Yes] if a “Terminal Settings change” dialog box is displayed. The “Terminal Connection Manager” dialog box will be displayed after restarting.
NOTE
Click [No] to finish the “eClient Setup Wizard” and display “Terminal Connection Manager” on the screen. The setting is not activated until the 620L is restarted.
18 3. SETTING UP the eClient 620L

4. ADDING & CHANGING A CONNECTION NAME

This chapter shows how to add, delete, and modify connection names to a WTS. All the settings are managed in the “Terminal Connection Manager”.

4-1. Adding a Connection Name

These are settings for the server connection. Each protocol has different settings. Please install the appropriate settings.
In use of the Microsoft Remote Desktop Client (RDP) page 20
In use of the Citrix ICA Client (ICA) page 21
NOTE
Please install Citrix MetaFrame server into the Server when using the ICA protocol.
4. ADDING & CHANGING A CONNECTION NAME 19
Loading...
+ 43 hidden pages