Table of Contents
EZ 250
Items Provided by Installer 2
Preloaded Eiki Code 3
Preloaded Timer 4
EZ 250
EZ 250
Programming EZ 250
Labeling Buttons 18-19
Parts List 1
Layout 5
Software Installations 6
7-17
Installing EZ 250
DIP Switch Settings 25
EZ 250
EZ 250
Software Troubleshooting 26
Operational Troubleshooting 26
20-24
i
EZ 250 Parts List
• EZ 250
• AC/DC Power Supply
• EZlink Hub
• Plug and Play Set Up Guide
• 2 Screws
• 2 Label Transparency Sheets
-1 -
Items Provided by Installer
• If you are going to need to program the EZ-250, a DB 9 serial cable to connect
your computer to EZ 250
• Slotted screw driver
• Hex driver
• 2 pieces of standard Cat 5 cables to run between the EZ 250 and EZlink Hub
• The control cable that was included with the projector or that was purchased
later
• DB 9 serial cable if connecting to an NPC-1
-2 -
Preloaded Eiki Code
PLUG AND PLAY SET UP
Your EZ-250 system is set to operate right out of the box. It has been pre-configured to work with
the current line of EIKI projectors. If you are using one of the projectors listed below simply
connect the control cable from the projector to the RS-232c port on the EZ-250 interface. Connect
two cat5 cables between the same numbered ports (1 to 1, 2 to 2) on the controller and interface.
If you are using a mini-din 8 to DB9 sub cable you must set the dip switches for null modem
operation. After you have connected the EZ-250 controller to the EZ-250 interface and the
projector, connect the power to the EZ-250 interface.
PRESET CODE The configuration for the following data projectors are preset at the factory:
If you are controlling:
LC-X60, LC-X70, LC-XB15, LC-XB21, LC-XB22, LC-XB26, LC-XB30, LC-SB21
NOTHING FURTHER IS REQUIRED!
The default button configuration is:
Button 1 On Button 2 OFF
Button 3 Volume Up Button 4 CompositeVid Button 5 Computer 1 Button 6 Black Screen
Button 7 Volume Down Button 8 S-Video Button 9 Computer 2 Button 10 Auto Image
The other EIKI standard configurations can still be accessed without disconnecting the system. While the controller is
powered up, press button 8 down for 30 seconds (it really takes 30 seconds, please be patient.)
starts to blink, continue pressing the button down. The button will blink once then pause for about
3 seconds then it will blink twice, then pause for 3 seconds, etc. After you have arrived at the
proper number, release Button 8. Each set of blinks loads a different set of drivers for EIKI model
projectors.
After the button
One Blink LC-X60, LC-X70, LC-XB15, LC-XB21, LC-XB22, LC-XB26, LC-XB30, LC-SB21
Two Blinks LC-XG110, LC-XG210
Three Blinks LC-SD10, LC-SD20
Four Blinks LC-X6, LC-SX6, LC-XT3, LC-UXT3
Five Blinks EIP-200, EIP-1500T, EIP-2500, EIP-3500, EIP-4500
-3 -
Preloaded Timers
The controller is preloaded with different timers that will turn off the projector after
a specified period. This function can be selected by pressing button 9 down for
30 seconds, after the button starts to blink, continue pressing the button down.
The button will blink once then pause for about 3 seconds then it will blink twice,
then pause for 3 seconds, etc. After you have arrived at the proper number,
release the button. Each set of blinks loads a different timer option:
One hour = One Blink
Two hours = Two Blinks
Three hours = Three Blinks
Four hours = Four Blinks
Five hours = Five Blinks
Six hours = Six Blinks
Seven hours = Seven Blinks
Eight hours = Eight Blinks
Nine hours = Nine Blinks
No timer = Ten Blinks
-4 -
EZllink 1 cable carries
Power and both contact
closures
EZlink 2 cable carries both
RS 232 ports
EZ 250 Layout
RS-232-1
Hooked up to projector
when using NPC-1
also hooked up to another
device when NPC-1 is not
used or just nothing
RS-232-2
Programming Port
Also goes into the NPC 1
and when two projectors
are hooked up
RS-232-3
Not Used
Connects to EZlink 1
on the hub
Connects to EZlink 2
on the hub
-5 -
Contact Closures
wires