Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation of your Fire / CO Alarm Interface. The booklet should be regarded as part of the product. If you are just installing the unit, the booklet must be given to the householder. The booklet is to be given to any subsequent user.
Model: Ei414
Fire / CO Alarm Interface
service
ON TEST
OFF
Fire / CO Alarm Interface
Alarm Code LED’s
RadioLink LEDPower LED
Key Switch On Off Test
open screws
then insert screwdriver into the notch to remove cover
How to remove Cover
Fire / CO Alarm Interface
Wireless Smoke Alarm System Wireless Smoke &
Carbon Monoxide Alarm System
RF Smoke Alarm
RF Smoke Alarm
RF Smoke Alarm
Alarm Controller
RF Smoke Alarm
Model No. - Alarms Comment
Ei262 Mains Carbon Monoxide Alarms The Ei262 has built-in RadioLINK technology
Ei140RC, Ei160RC & Ei2110 Series Smoke Alarms
Due to our continuous improvements policy, product performance and features are being frequently updated - See Contact Us section
The Alarms must be fitted on Ei168RC RadioLINK bases
Ei605 & Ei650 Series Smoke Alarms Alarms must be fitted with the correct Ei605 & Ei650 series RadioLINK module
Ei208W powered for life Carbon Monoxide Alarms The Alarms must be fitted with Ei200MRF RadioLINK modules
Ei170RF & other RadioLINK devices Contact us or visit our website for details
Works
with
RF CO Alarm
Alarm Interface Alarm Interface
RF Smoke Alarm
Alarm Controller
External Panel
(Fire / Telecare etc.)
Ei414
service
ON TEST
OFF
Fire / CO Alarm Interface
Hardwired Output Connection Diagram
230VAC
11 - 30VDC
Ei208WRF
For connection to External Panel see Manufacturers instructions
Ei650RF Ei168RCEi262 Ei450
RF Signal Input
from Ei Alarm System
Fire / CO Alarm Controller
Ei414
For connection to External Panel see Manufacturers instructions
Ei414
service
ON TEST
OFF
Fire / CO Alarm Interface
230VAC
11 - 30VDC
Ei208WRF
For connection to External Panel & RF Transmitter see Manufacturers instructions
For connection to External Devices see Manufacturers instructions
Ei650RF Ei168RCEi262 Ei450
RF Signal Input
from Ei Alarm System
Fire / CO Alarm Controller
Ei208WRF Ei650RF Ei168RCEi262 Ei450
RF Fire Signal
Output
Fire / CO Alarm Controller
External RF Panel
(Fire / Telecare etc.)
Wireless (RF) Connection Output Diagram
External Device
(Strobe etc.)
Ei414
service
ON TEST
OFF
Fire / CO Alarm Interface
External
Fire Panel
External
Device
(sprinkler flow valve)
Input Connection Diagram
230VAC
RF
Transmitter
RF
Transmitter
RF
Transmitter
Ei164RC Heat Alarm with Ei168RC RadioLINK Base
Ei414
Ei166RC Smoke Alarm with Ei168RC RadioLINK Base
RadioLINK Mains Powered Alarm System
Fire / CO Alarm Controller
Ei450 Alarm Controller
service
ON TEST
OFF
Fire / CO Alarm Interface
External Panel
(Fire / Telecare etc.)
Ei650RF Smoke Alarm
Ei603TYCRF Heat Alarm
RF Transmitter
RadioLINK Battery Powered Alarm System
Ei164RC Heat Alarm with Ei168RC RadioLINK Base
Ei414
Ei166RC Smoke Alarm with Ei168RC RadioLINK Base
Ei450 Alarm Controller
Fire / CO Alarm Controller
Ei450 Alarm Controller
service
ON TEST
OFF
Fire / CO Alarm Interface
(Fire / Telecare etc.)
Ei414
service
ON TEST
OFF
Fire / CO Alarm Interface
External RF Panel
(Fire / Telecare etc.)