Eicon Networks DN-I300TEPHMP User Manual

Dialogic
®
DN/I300TEPHMP Digital Network Interface Board
Installation Guide
Optional ISA Edge
Retainer
P5
(on reverse
side of board)
CT Bus
Connector
Physical Layout
Red
Yellow
Green
Loopback
Alarm/Status LEDs
2. Before You Begin
Protecting the Board from Damage
1
CAUTION: All computer boards are sensitive to
electrostatic discharge (“ESD”). Handle all static­sensitive boards and components at a static-safe work area, and observe anti-static precautions at all times.
If you are not familiar with ESD safety precautions, visit http://dialogic.com/support/hwinstall to learn more.
configuration data. This utility can be accessed from the Start menu in the Dialogic HMP software program folder. For more information about board identification, see the DCM online help.
In a Linux system, you must set SW1 to a unique number for each installed board. Use a non­magnetic screwdriver to turn SW1 to one of 16 board settings, 0–9 or A–F. After the hardware and the Dialogic HMP software are installed, refer to the proper configuration files to retrieve the assigned board instance ID number(s). For more information about Linux configuration files, see the Dialogic HMP software release documentation.
Copyright © 2005-2007 Dialogic Corporation.
All rights reserved.
The Dialogic® DN/I300TEPHMP Digital Network Interface Board (“board”) is a high-density, high­performance, network interface board in a universal PCI form factor with one T1/E1 digital network interface. This board is designed to be used with Dialogic (Release 2.0 or higher). The DN/I300TEPHMP Digital Network Interface Board includes the following components:
RJ-48C Jack: One connector to a T1 or E1 trunk. General Network Interface Alarm LED: When lit,
Reset LED: When lit, indicates that the board is in
Power LED: When lit, indicates power is on. SW1: Rotary switch used to set board identification
Alarm/Status LEDs: A set of four LEDs for the
®
Host Media Processing (HMP) software
indicates an alarm condition is present on the trunk.
the reset state.
(Linux system only).
trunk. During power-up, the LEDs indicate Power On Self Test (POST) status. After the board is started, the green, yellow, and red LEDs indicate normal operation or Carrier Failure Alarms (CFAs) as shown in the following table. The Loopback LED indicates when the trunk is in loopback mode.
Green Yellow Red Conditions
ON OFF OFF Normal Operation
OFF OFF ON Loss of Signal (LOS)
ON OFF ON Red Alarm
ON ON OFF Yellow Alarm/Remote Alarm
ON ON ON Alarm Indicator Signal (AIS)
Indicator (RAI)
CT Bus Connector: Connector to CT Bus. Optional ISA Edge Retainer: Bracket used to
install board in an ISA form factor PCI slot.
P5: CT Bus Termination Jumper Block. Factory
default is unterminated. Signals must be terminated only on boards at each end of an optional CT Bus cable.
JP3X11 and JP4X11: Power-off Default Front End
Loopback for the trunk. Factory default is enabled (jumper clips installed).
JP5: Boot up Default Front End Loopback. Factory
default is enabled (jumper clip removed).
Universal PCI Bus Connector: Connector to
universal PCI Bus slot.
Additional Information
Additional information about the DN/I300TEPHMP Digital Network Interface Board is available from a number of sources.
Universal PCI Bus Connector
The product data sheet, available at
www.dialogic.com/products/list.asp
functional description as well as information about applications and configurations, features, and technical specifications.
Refer to the Release Guide and the online Release Update for your Dialogic (HMP) software release to verify that the DN/ I300TEPHMP Digital Network Interface Board is supported in the release and for information on any new features or issues that may relate to it.
The Regulatory Notices document that is packed with each Dialogic Network Interface Board contains safety warnings and national requirements for proper operation of telecommunications equipment.
JP5
SW1
Power LED
Reset LED
General Network Alarm LED
RJ-48C Jack
JP3X11
and JP4X11
, provides a
®
Host Media Processing
®
DN/I300TEPHMP Digital
http://
Unpacking the Board
CAUTION: Do not remove the board from the anti-
static packaging until you are ready to install it. Observe proper anti-static precautions at all times.
Unpack the board according to the following steps:
1. Prepare a static-safeguarded work area.
2. Carefully remove the board from the shipping carton and static-shielding bag. Handle the board by the edges and avoid touching the board's components.
3. Lay the board on the static-safe work surface.
Note: Place boards in static-shielding bags when carrying boards from station to station.
Setting the Board ID
The device driver assigns board instance numbers in ascending order (beginning with 0) as it detects each board in your system. A board instance number is the identification (ID) number used by the Dialogic recognize the board.
Note: If you add or remove a board, the system may change the existing board instance numbers, depending on the PCI bus and slot number where the board is installed or removed.
In a Windows system, leave SW1 (see Physical Layout) set to the factory default of 0 to let the system automatically assign board instance numbers by PCI bus slot number. After the hardware and the Dialogic HMP software are installed, refer to the Dialogic retrieve the assigned board instance ID number(s). Dialogic® Configuration Manager (DCM) is a utility that enables you to add new boards to your system, start and stop system service, and work with board
®
Host Media Processing (HMP) software to
®
Configuration Manager (DCM) to
Setting CT Bus Termination
This section applies if you are using a CT Bus cable to connect your board to other boards in the system.
Bus signals are terminated when the CT Bus jumper clip is installed. To terminate bus signals, install a jumper clip on the pair of CT Bus termination pins only on boards located at each end of the bus cable.
Factory default is unterminated (jumper clip removed).
The following figure shows the pair of pins used for CT Bus termination. Refer to P5 in the Physical Layout figure for the location of the jumper block.
CT Bus
Connector
CT Bus
Termination
Setting Power-off Default Front End Loopback
When the system shuts down (powers off), the board enables analog loopback to the connected trunk line. Factory default setting is enabled for the trunk (jumper clips are installed). To disable, remove the pair of jumper clips for the trunk.
The pair of jumpers for the trunk is JP3X11 and JP4X11. Refer to the Physical Layout figure for the location of the jumpers.
Part number: 64-0083-02
Setting Boot Up Default Front End Loopback
When the system is started or restarted, the board enables analog loopback to the connected trunk line and provides digital loopback to the board. Factory default setting is enabled (jumper clip is removed). To disable, install the jumper clip. Refer to JP5 in the Physical Layout figure.
3. Installing the Board
CAUTION: These procedures assume familiarity
with the general terminology associated with electronic equipment and with the safety practices and regulatory compliance required for using and modifying electronic equipment. These procedures should be performed only by qualified technical personnel.
WARNING! Unplug the equipment before performing the procedures described here. Failure to disconnect the power before you open the chassis can result in personal injury. Ensure that the system is disconnected from its power source and from all telecommunications links, networks, or modem lines whenever the chassis cover is removed. Do not operate the system with the cover removed.
CAUTION: To avoid possible damage to the board,
remove power from the computer before beginning installation. Observe proper anti-static precautions at all times while handling and installing the board.
Note: It is recommended that you install the hardware before installing the software.
Install the board as follows:
1. With your computer at a static-safe work area, switch off the power and disconnect the power cord.
2. Remove the computer cover.
3. Select an empty PCI expansion bus slot and remove the slot’s retaining screw and coverplate.
4. If you are installing your board in an ISA form factor PCI slot, optionally install an ISA edge retainer on the board.
5. Using the slot’s board guides, insert the edge connector of the board into the bus slot. Press
firmly until the board is securely seated in the slot.
6. Replace and tighten the retaining screw to secure the board firmly in the bus slot.
7. Repeat steps 3–6 for each board you are installing.
8. If appropriate, use an optional CT Bus cable to connect the board(s) you are installing to other boards in the system. To preserve the electrical integrity of the CT Bus, use a CT Bus cable with the appropriate number of connectors (“drops”). It is recommended that no more than two connectors at either end of the cable be left unused. For boards located at each end of the CT Bus cable, be sure to set bus termination appropriately as described in the Setting CT Bus Termination section.
9. Replace the computer cover when finished and reconnect the power cord.
10. Turn on the power to the computer.
Note: If your BIOS is set to use Plug and Play technology and there are ISA boards in your system, an IRQ conflict can occur if your PCI board is assigned the same IRQ as an ISA board. This can cause the machine to stop responding. To prevent this conflict, enter the BIOS and reserve the appropriate IRQs (those used by your ISA boards) for ISA use only.
4. Connecting to External
Equipment
Connect the RJ-48C jack on the board bracket to the switch using a digital T1 or E1 crossover cable. If you are building your own cable, you should be familiar with the connector pin designations for the RJ-48C jack.
RJ-48C Connector Pin Designations
Pin 1
Pin
Function
RCV_RING
1
RCV_TIP
2
N/C
3
XMIT_RING
4
XMIT_TIP
5
N/C
6
N/C
7
N/C
8
5. After Installing the Board
After installing the board, proceed with these activities:
Installing the software, as described in the software installation guide for your software release
Configuring the software, as described in the configuration guide for your software release
For technical specifications and product information go to: http://www.dialogic.com/ products.htm.
Note: If you are adding hardware to an existing system, you do not need to uninstall existing Dialogic
®
Host Media Processing (HMP) software.
6. Removing the Board
Removal of the board is a straightforward process. Remove the board using the reverse of the procedure described in Section 4, Installing the Board above.
7. Warranty and Return Information
Warranty Period
For specific warranty information for this board, refer to the Warranty section of the Products page, located at this URL: http://www.dialogic.com/ warranties/.
Contacting Technical Support
Dialogic provides technical support for its products through a network of value added distributors who are trained to answer technical questions on installing and configuring Dialogic® products. If you are unsure how to contact your support channel, please call Dialogic in the United States at 973-967­6600 (9am-5pm EST) and we will assist in obtaining the appropriate support channel.
Outside the United States please refer to http:// www.dialogic.com/support/contact to obtain local contact information. Dialogic also provides direct support via Dialogic For more details of direct support from Dialogic please refer to:http://www.dialogic.com/support/ DialogicPro
®
Pro™ Services agreements.
Returning a Product
To return a board for warranty repair or any other returns, please refer to the following: http:// www.dialogic.com/support/hwfaults.
8. Sales Assistance
If you have a sales question, please contact your local Sales Representative or the Regional Sales Office for your area. Address, telephone and fax numbers, are available at the Dialogic website located at: http://www.dialogic.com/contact.htm.
To purchase Dialogic® products, please refer to the following website to locate the appropriate supplier: http://www.dialogic.com/purchase.htm.
All contents of this document are furnished for informational use only and are subject to change without notice and do not represent a commitment on the part of Dialogic Corporation or its subsidiaries (“Dialogic”). Reasonable effort is made to ensure the accuracy of the information contained in the document. However, Dialogic does not warrant the accuracy of this information and cannot accept responsibility for errors, inaccuracies or omissions that may be contained in this document.
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH DIALOGIC® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN A SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO LIABILITY WHATSOEVER, AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF DIALOGIC PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY.
Dialogic products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications.
It is possible that the use or implementation of any one of the concepts, applications, or ideas described in this document, in marketing collateral produced by or on web pages maintained by Dialogic may infringe one or more patents or other intellectual property rights owned by third parties. Dialogic does not provide any intellectual property licenses with the sale of Dialogic products other than a license to use such product in accordance with intellectual property owned or validly licensed by Dialogic and no such licenses are provided except pursuant to a signed agreement with Dialogic. More detailed information about such intellectual property is available from Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9.
Dialogic encourages all users of its products to procure all necessary intellectual property licenses required to implement any concepts or applications and does not condone or encourage any intellectual property infringement and disclaims any responsibility related thereto. These intellectual property licenses may differ from country to country and it is the responsibility of those who develop the concepts or applications to be aware of and comply with different national license requirements.
Dialogic, Diva, Eicon, Eicon Networks, Eiconcard, Dialogic Pro and SIPcontrol, among others, are either registered trademarks or trademarks of Dialogic. Dialogic's trademarks may be used publicly only with permission from Dialogic. Such permission may only be granted by Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9. Any authorized use of Dialogic's trademarks will be subject to full respect of the trademark guidelines published by Dialogic from time to time and any use of Dialogic’s trademarks requires proper acknowledgement. The names of actual companies and products mentioned herein are the trademarks of their respective owners.
Loading...