Eicon Networks DM-V600A-2E1-PCI, Dialogic 64-0074-02 User Manual

®
Dialogic DM/V600A-2E1-PCI
Media Board
Quick Install Card
Part Number 64-0074-02
Dialogic Corporation.
All rights reserved.

Protecting the Board from Damage

CAUTION: All computer boards are sensitive to
electrostatic discharge (“ESD”). Handle all static­sensitive boards and components at a static-safe work area, and observe anti-static precautions at all times.
If you are not familiar with ESD safety precautions, visit
http://www.dialogic.com/support/hwinstall to learn more.
Unpack the Dialogic® DM/V600A-2E1-PCI Media Board (“board”) according to the following steps:
1. Prepare a static-safeguarded work area.
2. Carefully remove the board from the shipping
3. Lay the board on the static-dissipative work
Note: Place boards in static-shielding bags when carrying boards from station to station.
CAUTION: Do not remove the board from the anti-static packaging until you are ready to install it. Observe proper anti-static precautions at all times.
Before You Begin
Unpacking the Board
carton and anti-static packaging. Handle the board by the edges and avoid touching the board’s components.
surface.
Physical Description
CH4 CH3 CH2CH1
Red
Yellow
Green
Loopback
7
6
5
3
2 1
4
1
2
JP2B

Configuring the Hardware

Board Identification

The device driver, part of the system software, assigns board instance numbers in ascending order (beginning with 0) as it detects each board in your system. A board instance number is the identification (ID) number used by the system software to recognize the board.
Note: If you add or remove a board, the system may change the existing board instance numbers, depending upon the PCI bus and slot number where the board is installed or removed.

Windows Systems

Leave SW1 set to the factory default of 0 to let the system automatically assign board instance numbers by PCI bus slot number.
After the hardware and the system software are installed, refer to the Dialogic utility to retrieve the assigned board instance ID number(s). For more information about board identification, see the DCM online help.
®
Configuration Manager (DCM)
8
JP2A
1. RJ-48C jacks: Connectors to external
digital telephone network interface.
2. General Network Interface Alarm LED
3. Power LED
4. Reset LED
5. SW1: Rotary switch to set board
identification (Linux systems only).
6. Alarm LEDs: During power-up, indicate
Power on Self Test (POST) status. During operation CH1 and CH2 LEDs indicate network alarms for each trunk.
9
10
Red—Alarm to indicate loss of signal Yellow—Alarm to indicate loss of frame
synchronization at far end of external network Green—Indicates signal present; powered up and receiving signal from external E1 sources Loopback—Indicates loopback mode is activated
7. CT Bus/MVIP Bus Termination Jumpers:
Bus signal is terminated when the corresponding jumper clip is installed. Note: Signal must be terminated only on boards at each end of the CT Bus cable.
JP2A—CT Bus termination jumper JP2B—MVIP Bus termination jumper
8. P3: CT Bus connector
9. ISA Edge Retainer
10.Signal Processing Daughterboard

Linux Systems

In a Linux system, you must set SW1 to a unique number for each installed board. Use a non-magnetic screwdriver to turn SW1 to one of 16 board ID settings, 0–9 or A–F.
After the hardware and the system software are installed, refer to the proper configuration files to retrieve the assigned board instance ID number(s). For more information about Linux configuration files, see the Dialogic
®
System Software documentation.

Installing the Hardware

1. With your computer on the static-safe work area,
switch off the power and disconnect all power cords from the electrical outlets.
2. Remove the computer cover.
3. Select an empty PCI expansion bus slot and remove
the slot’s retaining screw and access cover plate (if applicable).
4. If you are not installing your board in an ISA form
factor PCI slot, remove the ISA edge retainer.
5. Using the slot’s board guides, insert the board’s edge
connector into the bus slot. Press firmly until the board is securely seated in the slot.
Installing a PCI Board
Computer
Chassis
Remove
Cover
Plate
32-Bit
PCI Slot
16-Bit
ISA Slot
Board
PCI
6. Replace and tighten the slot’s retaining screw to
secure the board firmly in the chassis (if applicable).
7. Connect external digital telephone cables to the
RJ-48C jacks on the board bracket. The topmost RJ-48C jack is for trunk 1 and the second RJ-48C jack is for trunk 2.
Pinouts for the RJ–48C
Jacks on Bracket
RCV_RING
1
RCV_TIP
2
CHASSIS GROUND
3
XMIT_RING
4
XMIT_TIP
5
CHASSIS GROUND
6
CHASSIS GROUND
7
CHASSIS GROUND
8
1 2 3 4 5 6 7 8
Network Interface
Cable Connector
Pin 1
8. Repeat steps 3-7 for each additional board you are
installing.
9. Use the CT Bus cable to connect the board(s) you
are installing to other boards in the system. To preserve the electrical integrity of the CT Bus, use a CT Bus cable with the appropriate number of connectors (“drops”). It is recommended that no more than two connectors at either end of the cable be left unused.
10. Your system may include both CT Bus and SCbus
boards. To connect both board types, you must install a CT Bus/SCbus Adapter on one of the CT Bus boards in a system. See the CT Bus/SCbus Adapter Quick Install Card for installation details about the Adapter and the bus cables
Installing the CT Bus Cable
Colored
Stripe
(Pin 1)
CT Bus
Cable
Dialogic also provides direct support via Dialogic® Pro™ Services agreements. For more details of direct support from Dialogic please refer to:
http://www.dialogic.com/support/DialogicPro.
Returning a Product
To return a board for warranty or any other returns, please refer to the following:
Note: Your CT Bus cable may have a different number of connectors (drops).
11. Install CT Bus Termination Jumpers only on boards
located at each end of the CT Bus cable. See the “Physical Description” section for jumper details.
12. Replace the computer’s cover when finished and
reconnect the power cords.
13. Turn the computer’s power ON.
CAUTION: If your BIOS is set to use Plug and Play technology and there are ISA boards in your system, an IRQ conflict can be created if a PCI board is assigned the same IRQ as an ISA board. This could cause the machine to stop responding. You can prevent this by entering the BIOS and reserving the appropriate IRQs (those used by your ISA boards) for ISA use only.

After Installing the Hardware

After installing the hardware, run the Dialogic Configuration Manager (DCM) as described in the installation instructions included with the Dialogic System Software to configure your system.
®
®
For technical specifications and product information go to:
http://www.dialogic.com/products.htm.

Warranty and Return Information

Warranty Period
For specific warranty information for this board, refer to the Warranty section of the Products page, located at this URL: http://www.dialogic.com/warranties/.
Contacting Technical Support
Dialogic provides technical support for its products through a network of value added distributors who are trained to answer technical questions on installing and configuring Dialogic® products. If you are unsure how to contact your support channel, please call Dialogic in the United States at 973-967-6600 (9am-5pm EST) and we will assist in obtaining the appropriate support channel. Outside the United States please refer to
http://www.dialogic.com/support/contact .
http://www.dialogic.com/support/hwfaults .

Sales Assistance

If you have a sales question, please contact your local Sales Representative or the Regional Sales Office for your area. Address, telephone and fax numbers, are available at the Dialogic website located at:
http://www.dialogic.com/contact.htm. To purchase
Dialogic to locate the appropriate supplier:
http://www.dialogic.com/purchase.htm.
All contents of this document are furnished for informational use only and are subject to change without notice and do not represent a commitment on the part of Dialogic Corporation or its subsidiaries (“Dialogic”). Reasonable effort is made to ensure the accuracy of the information contained in the document. However, Dialogic does not warrant the accuracy of this information and cannot accept responsibility for errors, inaccuracies or omissions that may be contained in this document.
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH DIALOGIC® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN A SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO LIABILITY WHATSOEVER, AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF DIALOGIC PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY.
Dialogic products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications.
It is possible that the use or implementation of any one of the concepts, applications, or ideas described in this document, in marketing collateral produced by or on web pages maintained by Dialogic may infringe one or more patents or other intellectual property rights owned by third parties. Dialogic does not provide any intellectual property licenses with the sale of Dialogic products other than a license to use such product in accordance with intellectual property owned or validly licensed by Dialogic and no such licenses are provided except pursuant to a signed agreement with Dialogic. More detailed information about such intellectual property is available from Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9. Dialogic encourages all users of its products to
procure all necessary intellectual property licenses required to implement any concepts or applications and does not condone or encourage any intellectual property infringement and disclaims any responsibility related thereto. These intellectual property licenses may differ from country to country and it is the responsibility of those who develop the concepts or applications to be aware of and comply with different national license requirements.
Dialogic, Diva, Eicon, Eicon Networks, Eiconcard and SIPcontrol, among others, are either registered trademarks or trademarks of Dialogic. Dialogic's trademarks may be used publicly only with permission from Dialogic. Such permission may only be granted by Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9. Any authorized use of Dialogic's trademarks will be subject to full respect of the trademark guidelines published by Dialogic from time to time and any use of Dialogic’s trademarks requires proper acknowledgement. The names of actual companies and products mentioned herein are the trademarks of their respective owners.
®
products, please refer to the following website
Loading...