Eemax EX2412T, EX610, EX3012T, EX480, EX3512T Service manual

...
®
“Thermostatic”
ELECTRIC INSTANTANEOUS WATER HEATER
INSTALLATION GUIDE AND OWNERS MANUAL
WARNING
BEFORE ATTEMPTING INSTALLATION OF THIS UNIT OR MAKING ANY
ADJUSTMENTS TO THE UNIT, ALWAYS BE SURE CIRCUIT BREAKER IS OFF
FAILURE TO GROUND THE SYSTEM MAY RESULT IN SERIOUS INJURY OR DEATH
INSTALLER/ CONSUMER RESPONSIBILITIES
READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL OR
OPERATE THIS WATER HEATER. IF THE SAFETY RULES ARE NOT FOLLOWED,
THE UNIT WILL NOT OPERATE PROPERLY AND IT COULD CAUSE DEATH,
SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
WARRANTY OF THIS WATERHEATER WILL DEPEND
ON PROPER INSTALLATION AND OPERATION. THE WARRANTY
WILL BE VOID IF THE DESIGN HAS BEEN ALTERED IN ANY WAY
WHATSOEVER. THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE
FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION
AND OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES.
Eemax Inc., 353 Christian St. Oxford, CT. 06478
THE INSTALLATION MUST CONFORM WITH THE INSTRUCTIONS IN THIS
MANUAL AND LOCAL CODES, OR INTHE ABSENCE OF
LOCAL CODES, WITH THE LATEST EDITION OF THE
NATIONAL ELECTRICAL CODE. THIS PUBLICATION IS AVAILABLE FROM
YOUR LOCAL GOVERNMENT, ELECTRIC CO., PUBLIC LIBRARY, OR BY
WRITING UNDERWRITERS LABORATORIES, 333 PFINGSTEN RD.,
NORTHBROOK, IL. 60062
TEL:1-800-543-6163, 203-267-7890, FAX: 203-267-7975, e-mail: eemaxinc@aol.com
IF YOU REQUIRE HELP OR HAVE ANY QUESTIONS RELATING TO THE
INSTALLATION OR PERFORMANCE OF THIS HEATER, PLEASE CALL
OUR TECHNICAL SERVICE DEPARTMENT TOLL FREE:1-800-543-6163.
HAVE THE INFORMATION LISTED BELOW BEFORE CALLING:
MODEL NO.___________SERIAL NO.___________INSTALLATION DATE_____
COMPRESSION
NUT
PART# EX17
TRIAC
PART # EX 18
CONTROL BOARD
EX100/240 for 240v, 208v
EX100/277 for 277V
ELEMENT CARTRIDGE
HEATER MODEL/ORDER REF. CARTRIDGE REF #
EX2412T EX610 EX3012T EX480 EX3512T EX410 EX 55T EX 1050
EX 65T EX 890
EX 75T EX 770
EX 95T EX 630
EX 8208T EX 520
EX 60T EX 1280
EX 80T EX 960
EX 90T EX 850
EX 100T EX 760
Replacement Parts for “Thermostatic” Units
INSTANT COMFORT…ENDLESS SAVINGS
COMPRESSION
SLEEVE
PART # EX16
TEMP ADJ KNOB
RELAY
GROUND
WIRE
GENERAL
The Eemax “Thermostatic” heater is specifically designed
to take in cold or preheated water and heat it to temperatures suitable
for the normal domestic usage up to a maximum of 1400 F. To obtain
optimum performance and energy savings, the unit should be located as
close as possible to the point of use. The unit is supplied with compression
rings and nuts suitable for direct coupling to 1/2” copper or plastic piping. Do not use additional screwed fittings or pipe dope. Doing so will void the
warranty. DO NOT SOLDER PIPES WHILE THE UNIT IS INSTALLED
(serious damage to the electronic flow switch will result).
This heater must have its own independent circuit, using
a correctly rated breaker and
wires suitable for at least 75 oC operation.
Failure to ground this system may result in death or serious injury.
1) MOUNTING THE UNIT
1) The unit should be mounted as close to the point of use as possible.
2) This unit must only be mounted in the vertical position with the water fittings at the bottom of the unit. Mounting other than in the vertical position WILL cause element burn out.
3) The cold water inlet is on the right hand side and the hot water outlet is on the left hand side. Under NO circumstances can these be reversed.
4) Leave a minimum of 8” above the unit for easy replacement of the element.
5) The heater should be fixed to the wall using the four mounting holes at each corner of the backplate.
NOTE: The heater should be installed below the level of all hot water outlets serviced by this heater.
NOTE: PRESSURE RELIEF DEVICE This unit is not required by UL to have a Pressure and Temperature safety relief valve (PTRV). You should check with local codes to find out if one is required in your area. If local codes require the use of temperature and pressure relief valve it should be installed on the outlet hot water pipe before the outlet ball valve.
TROUBLE SHOOTING
SYMPTOM: NO HEAT INDICATOR LIGHT OFF
1) ELECTRIC SUPPLY IS OFF Turn on the main breaker.
2) Check the ECO (red re-set button) if tripped please call tech support
3) NO OR LOW WATER FLOW Ensure that the minimum flow rate to switch on your heater is met. “EX100T, 95T, 90T, 8208T” Models minimum flow rate = 0.75 gpm “EX80T, 75T, 65T” Models minimum flow rate = 0.6 gpm “EX60T, 55T” 2412T,3012T, 3512T Models minimum flow rate = 0.5 gpm Also check that the inlet filter screen is clear from any debris. This is located in the brass inlet boss.
4) WATER CONNECTIONS ARE REVERSED Cold water inlet = right side, hot water outlet = left side.
5) ELEMENT BURNED OUT TURN OFF THE breaker! Using an ohmmeter test the resistance of the heating element across the two threaded termination rods on top of the element. The resistance reading should be under 10 ohms. If the resistance is much greater than this value, call Eemax for a replacement element.
SYMPTOM: NO HEAT OR LOW TEMPERATURE WITH INDICATOR LIGHT ON
1) WATER FLOW TOO HIGH Reduce the water flow by using an outlet ball valve. See page 3 for temperature rise at various flow rates.
2) INCORRECT POWER SUPPLY Make sure that the unit is connected to the voltage supply specified on the rating label on the the front cover of the unit and no other.
3) ELEMENT BURNED OUT TURN OFF THE breaker! Repeat the steps from paragraph 4 above.