Three Phase
™
Triple Module, Commercial/Industrial Thermostatic 3-Phase Heater
Applications
•
Eye/face wash
•
Where tepid water is needed
•
Multiple lavatories
•
Restaurants and other food service requirements
•
Booster applications
•
Manufacturing and wash down processes
•
Commercial and industrial
Performance Features
•
Hot or cold water feed
•
Available electrical models are 480V Delta (ED models) or 208V
Delta (EX models) no neutral leg required
•
Fitted with 1/2" compression ttings and electrical entry on the
bottom
•
Built in over temp protection
•
Flow switch activates heater only on demand (no standby heat
loss)
•
Save water – "Point of use application"
•
Continuous hot water – no storage capacity to run out
•
Factory set temperature available. Range ambient to 180°F
•
Capacity to 5 GPM (T3 only), 4 GPM (T2T)
•
Thermostatic control. Microprocessor provides stable outlet
temperatures
•
Warranty, ve (5) years limited on leaks, one (1) year parts
•
Field serviceable replaceable cartridge element
Optional Features
•
Emergency eye/face wash ANSI Z358.1 (EE)
•
Factory set ambient to 180°F (FS)
•
Multi lavs 0.3 turn on. Staged up to 4 lavs 105°F-110°F temp
setting, aerators supplied (ML)
•
Sanitation 180°F (S)
•
N4, N4X (304SS) enclosures
Product Specications:
Dimensions: 18.25" x 12.25" x 4.5"
Weight: 15 lb
Cover: Powder Coated Steel
Color: White
Element: Triple replaceable Nichrome cartridge elements
insert
Fittings:
1/2" compression ttings at bottom of unit
Min. Dynamic Operating Pressure: 25 PSI
Max. Dynamic Operating Pressure: 150 PSI
U.S. Patent #'s: 4,762,980 and 4,960,976
Special Design Service
Inquiries for units for unique applications are welcome.
Call our Technical Service department at 1-800-543-6163.
Electrical conguration and requirements
All Eemax three phase units are custom made to order and as such, are non-returnable
and non-refundable. Check your electrical supply, making sure all criteria for operating your
Eemax water heater are met.
Eemax 600V, 480V and 208V
Three Phase Units Delta Conguration
Requires: 3 Lives and 1 Ground (earth)
Suggested Specication
Tankless water heater shall be an Eemax "Three Phase" model
number _________________________.
Element shall be replaceable cartridge insert. Element shall be
iron free, Nickel Chrome material. Heater shall be tted with 1/2"
compression ttings. Heater shall be installed upright with water
connections on bottom. Hot water storage tanks prohibited. Unit
shall be Eemax or approved equal.
NOTE: Refer to rating chart for product information.
Enclosure to be tted with the following features:
_____ EE
_____ FS
_____ ML
_____ S
_____ N4
_____ N4X NEMA 4 stainless steel, corrosion-resistant cabinet
Specications
Tankless Electric Water Heater
*The wetted surface of this product
contacted by water contains less than
0.25% lead and meets NSF/ANSI 372
Emergency Eyewash. Meets ANSI tepid water
requirements
Factory Set. Customer specied factory-set not to
exceed temperature ambient to 180°F
Multi lavs 0.3 GPM turn on, staged up to 4 lavs
105°F-110°F temp setting, aerators supplied
Sanitation. Factory preset not to exceed
temperature of 180°F
NEMA 4 steel cabinet with powder coat nish
Information and product specications contained in this document are subject to change without notice. REV 2020-01
Three Phase
Triple Module, Commercial/Industrial Thermostatic 3-Phase Heater
Specications
Tankless Electric Water Heater
Sux Denitions
EE Meets ANSI Z358.1 emergency
FS
ML Multi lavs 0.3 turn on. Staged
S
1.87
1.30 7.02
NEMA 4/4X
2.89
eye/face wash tepid water requirements
Factory set ambient to 180°F
up to 4 lavs 105°F-110°F temp
setting
Sanitation 180°F
OUTLET
INLET
ELECTRICAL
20.00
INLETOUTLET
18.50
4XØ .500
MOUNTING HOLES
.90
18.50
1.93
RECOMMENDED
MODEL NUMBER kW
VOLTS 208 Three Phase Delta
C
EX180T2T
C
EX180T2T EE
C
EX180T2T S
C
EX180T2T ML
C
EX180T2T FS
C
EX180T3
C
EX180T3 EE
C
EX180T3 S
C
EX180T3 FS
C
EX240T2T
C
EX240T2T EE
C
EX240T2T S
C
EX240T2T ML
C
EX240T2T FS
C
EX240T3
C
EX240T3 EE
C
EX240T3 S
C
EX240T3 FS
VOLTS 480 Three Phase Delta
ED020480T2T
ED020480T2T S
ED020480T2T ML
ED020480T2T FS
ED020480T3
ED020480T3 EE
ED020480T3 S
ED024480T2T
ED024480T2T S
ED024480T2T ML
ED024480T2T FS
ED024480T3
ED024480T3 EE
ED024480T3 S
ED032480T2T
ED032480T2T S
ED032480T2T ML
ED032480T2T FS
ED032480T3
ED032480T3 EE
ED032480T3 S
ED032480T3 FS
†Temperature electronically limited to factory preset not to exceed temperature.
"C" indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No.
AMPS
PER PHASE
18 50/phase 8 AWG 0.7 4.0 61° 49° 41° 31° –
18 50/phase 8 AWG 0.7 4.0 † 49° 41° 31° –
18 50/phase 8 AWG 0.7 4.0 61° 49° 41° 31° –
18 50/phase 8 AWG 0.3 4.0 61° 49° 41° 31° –
18 50/phase 8 AWG 0.7 4.0 61° 49° 41° 31° –
18 50/phase 8 AWG 2.0 5.0 61° 49° 41° 31° 25°
18 50/phase 8 AWG 2.0 5.0 † 49° 41° 31° 25°
18 50/phase 8 AWG 2.0 5.0 61° 49° 41° 31° 25°
18 50/phase 8 AWG 2.0 5.0 61° 49° 41°
24 67/phase 4 AWG 0.7 4.0 82° 66° 55° 41° –
24 67/phase 4 AWG 0.7 4.0 † † 55° 41° –
24 67/phase 4 AWG 0.7 4.0 82° 66° 55° 41° –
24 67/phase 4 AWG 0.3 4.0 82° 66° 55° 41° –
24 67/phase 4 AWG 0.7 4.0 82° 66° 55° 41° –
24 67/phase 4 AWG 2.0 5.0 82° 66° 55° 41° 33°
24 67/phase 4 AWG 2.0 5.0 † † 55° 41° 33°
24 67/phase 4 AWG 2.0 5.0 82° 66° 55° 41° 33°
24 67/phase 4 AWG 2.0 5.0 82° 66° 55° 41° 33°
20 24/phase 10 AWG 0.7 4.0 68° 55° 46° 34° –
20 24/phase 10 AWG 0.7 4.0 68° 55° 46° 34° –
20 24/phase 10 AWG 0.3 4.0 68° 55° 46° 34° –
20 24/phase 10 AWG 0.7 4.0 68° 55° 46° 34° –
20 24/phase 10 AWG 2.0 5.0 68° 55° 46° 34° 27°
20 24/phase 10 AWG 1.0 5.0 † 55° 46° 34° 27°
20 24/phase 10 AWG 2.0 5.0 68° 55° 46° 34° 27°
24 29/phase 10 AWG 0.7 4.0 82° 66° 55° 41° –
24 29/phase 10 AWG 0.7 4.0 82° 66° 55° 41° –
24 29/phase 10 AWG 0.3 4.0 82° 66° 55° 41° –
24 29/phase 10 AWG 0.7 4.0 82° 66° 55° 41° –
24 29/phase 10 AWG 2.0 5.0 82° 66° 55° 41° 33°
24 29/phase 10 AWG 1.0 5.0 † † 55° 41° 33°
24 29/phase 10 AWG 2.0 5.0 82° 66° 55° 41° 33°
32 38/phase
32 38/phase 8 AWG 0.7 4.0 109° 87° 73° 55° –
32 38/phase 8 AWG 0.3 4.0 109° 87° 73° 55° –
32 38/phase 8 AWG 0.7 4.0 109° 87° 73° 55° –
32 38/phase 8 AWG 2.0 5.0 109° 87° 73° 55° 44°
32 38/phase 8 AWG 1.0 5.0 † † † 55° 44°
32 38/phase 8 AWG 2.0 5.0 109° 87° 73° 55° 44°
32 38/phase 8 AWG 2.0 5.0 109° 87° 73° 55° 44°
WIRE SIZE
(75° C/CU)
8 AWG 0.7 4.0 109° 87° 73° 55° –
TURN-ON
(GPM)
MAX FLOW
(GPM)
TEMPERATURE RISE °F
2.0
2.5
3.0
GPM
GPM
64/No. 88. CNL SKUs are Canada specic.
GPM
4.0
GPM
31° 25°
5.0
GPM
Information and product specications contained in this document are subject to change without notice. REV 2020-01