SafeAdvantage™ (NEMA 4 Incl.)
For Safety Applications – Eye/Face Wash and Drench Showers
Applications
•
Eye/face wash
•
Emergency drench showers
•
Where tepid water is needed
Performance Features
•
90°F max. output temperature
•
Fully Modulating - Predictive control algorithm and diverse safety
features ensures conformity to ANSI Z358.1 tepid water without
additional mixing valves (check local codes)
•
Fast response rate eliminates the requirement for any additional
hot water purge system (no drainage required)
•
T&P not required per UL499 - Check local codes
•
Thermo-Optical Sensor for infrared element monitoring
•
Field programmable, updatable rmware, and adjustable turn-on
•
LCD display and control with built in diagnostics
•
Standard model includes NEMA 4 cabinet; alternative cabinets
are available for upgrade
Optional Features
•
N4X (304SS) N4X6 (316SS) enclosures
•
Free standing legs
•
Freeze protection for harsh climate, up to -30°F
•
Non-fused or fused electrical disconnect
•
GFCI
•
Explosion proof – C1D2 Compliant, local certication required.
Class Z purge and pressurization system provided with pressure
switch for alarm controls. For classication other than C1D2
please contact the factory to discuss options.
•
Siren and Beacon – audible and visual alarm (C1D2 rated when
paired with Explosion proof package)
Product Specications
Min. Operating Pressure: 35 PSI
Max. Operating Pressure: 150 PSI
Optimum Operating Pressure: 60-90 PSI
U.S. Patent #'s: US20140023354 and US20140178057
Installation Requirements
•
Properly sized water hammer arrestor
•
Minimum 35 PSI dynamic pressure at inlet
•
Sediment lter installed on inlet
Special Design Service
•
Inquiries for units for unique applications are welcome.
Call our Technical Service department at 1-800-543-6163.
•
Custom orders non-refundable
Suggested Specication
Tankless water heater shall be an Eemax SafeAdvantage model
number AP_________________________.
Factory installation in a ______(N4/N4X/N4X6) enclosure.
Enclosure to be tted with the following features:
_____ FP Freeze protection (-30°F)
_____ EDS Non-fused disconnect
_____ FDS Fused disconnect
_____ EP Explosion proof (C1D2 compliant)
_____ GFCI True RMS GFCI with digital display and reset
_____ SK 24" legs for free standing applications
_____ RD Remote display
_____ SB Siren and Beacon
_____ DC Dry contact
_____ ES Emergency stop - push button
Tankless water heater must have water connections on the
bottom, and be constructed with NSF61 listed materials. Direct
heating element to be non-ferrous, cartridge style, designed for
eld replacement. Tankless water heater to utilize a dual PID
algorithm, actively managing power application to real-time system
demand. Integrated ow meter capable of volumes in excess of
30 GPM drives predictive control algorithm. Water heater must be
protected by redundant safeties. Redundant safeties to include
thermo mechanical safety switches, infrared element monitoring
via thermo optical sensors, and dual temperature monitoring via
primary control board. Tankless water heater user interface must
have the following capabilities:
•
•
•
•
•
•
•
•
Specications
Tankless Electric Water Heater
*The wetted surface of this product
contacted by water contains less than
0.25% lead and meets NSF/ANSI 372
Selectable display including Celsius/Fahrenheit, inlet
temperature, outlet temperature, ow rate, and setpoint
temperature.
Capable of displaying ow rate in gallons per minute or liters per
minute.
Diagnostic features to include error and fault code display.
Control board must maintain error/fault history of 9 events.
Capable of factory coded temperature setting (max. and min.)
Capable of rmware upgrades via USB port
Capable of BMS integration - contact factory
Conforms to ANSI Z358.1 tepid water without additional mixing
or purge features (inlet temperatures must not exceed 100ºF).
Information and product specications contained in this document are subject to change without notice. REV 2020-01
5
SafeAdvantage (NEMA 4 Incl.)
For Safety Applications – Eye/Face Wash and Drench Showers
Specications
Tankless Electric Water Heater
Sux Denitions
EE Emergency Eyewash. Max. outlet
temperature 90°F. Conforms to
ANSI Z3581.1 tepid water without
additional mixing valve. Shipped
with display "Locked."
EFD Emergency Eye, Face & Drench.
Max. outlet temperature 90°F.
Conforms to ANSI Z3581.1
tepid water without additional
mixing valve. Shipped with display
"Locked."
Note: Models with an EE or EFD sufx are not to
be fed to a thermostatic mixing valve. If a thermostatic mixing valve is required, heater of non EE or
EFD must be specied.
Note: Models with an EE or EFD sufx have a
90°F maximum temperature. Temperature rise
data is provided for reference, but temperature
is electronically limited to factory preset not to
exceed temperature.
PHD Pressure Drop 63-150 kW
Flow Rate (GPM) Delta PSI
2 0
3 0
4 0
6 0
8 1
11 3
12 4
15 6
18 8
20 10
22 13
24 14
27 17
30 22
33 26
35 30
37 34
40 43
MODEL NUMBER
VOLTS 208 Three Phase Delta
AP032208 EE N4
AP032208 EE N4X
AP036208 EE N4
AP036208 EE N4X
AP041208 EFD N4
AP041208 EFD N4X
AP054208 EFD N4
AP054208 EFD N4X
AP064208 EFD N4
AP064208 EFD N4X
VOLTS 480 Three Phase Delta
AP036480 EE N4
AP036480 EE N4X
AP039480 EE N4
AP039480 EE N4X
AP048480 EFD N4
AP048480 EFD N4X
AP054480 EFD N4
AP054480 EFD N4X
AP063480 EFD N4
AP063480 EFD N4X
AP072480 EFD N4
AP072480 EFD N4X
AP096480 EFD N4
AP096480 EFD N4X
AP108480 EFD N4
AP108480 EFD N4X
AP126480 EFD N4
AP126480 EFD N4X
C
AP144480 EFD N4
C
AP144480 EFD N4X
VOLTS 600 Three Phase Delta
C
AP061600 EFD N4
C
AP061600 EFD N4X
C
AP071600 EFD N4
C
AP071600 EFD N4X
C
AP102600 EFD N4
C
AP102600 EFD N4X
C
AP130600 EFD N4
C
AP130600 EFD N4X
C
AP150600 EFD N4
C
AP150600 EFD N4X
† Temperature electronically limited to factory preset temperature.
"C" indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No. 88.
kW
109,189
32
109,189
32
122,832
36
122,832
36
139,898
41
139,898
41
184,256
54
184,256
54
218,377
64
218,377
64
122,837
36
122,837
36
133,074
39
133,074
39
48 163,783 58 1.0 6 AWG † 82° 66° 55° 16° 14° 13° 11°
48 163,783 58 1.0 6 AWG † 82° 66° 55° 16° 14° 13° 11°
184,256
54
184,256
54
63 214,965 76 2.5 4 AWG † † 86° 72° 22° 19° 17° 14°
63 214,965 76 2.5 4 AWG † † 86° 72° 22° 19° 17° 14°
245,674
72
245,674
72
96 327,552 116 2.5 1 AWG † † † † 33° 29° 25° 22°
96 327,552 116 2.5 1 AWG † † † † 33° 29° 25° 22°
368,511
108
368,511
108
126 429,930 151 2.5 2/0 AWG † † † † 43° 37° 33° 29°
126 429,930 151 2.5 2/0 AWG † † † † 43° 37° 33° 29°
491,348
144
491,348
144
208,141
61
208,141
61
242,262
71
242,262
71
348,038
102
348,038
102
130 443,578 125 2.5 1 AWG † † † † 44° 39° 34° 30°
130 443,578 125 2.5 1 AWG † † † † 44° 39° 34° 30°
150 511,821 144 2.5 1/0 AWG † † † † 51° 45° 39° 34°
150 511,821 144 2.5 1/0 AWG † † † † 51° 45° 39° 34°
BTU/H
AMPS
PER
PHASE
89 1.0 3 AWG 73° 55° 44° 36° 11° 10° 8° 7°
89 1.0 3 AWG 73° 55° 44° 36° 11° 10° 8° 7°
100 1.0 3 AWG 82° 61° 49° 41° 12° 11° 9° 8°
100 1.0 3 AWG 82° 61° 49° 41° 12° 11° 9° 8°
113 1.0 2 AWG † 70° 56° 47° 14° 12° 11° 9°
113 1.0 2 AWG † 70° 56° 47° 14° 12° 11° 9°
150 1.5 1/0 AWG † † 74° 61° 18° 16° 14° 12°
150 1.5 1/0 AWG † † 74° 61° 18° 16° 14° 12°
178 2.5 3/0 AWG † † 87° 73° 22° 19° 17° 15°
178 2.5 3/0 AWG † † 87° 73° 22° 19° 17° 15°
43 1.0 8 AWG 82° 61° 49° 41° 12° 11° 9° 8°
43 1.0 8 AWG 82° 61° 49° 41° 12° 11° 9° 8°
47 1.0 8 AWG 89° 67° 53° 44° 13° 12° 10° 9°
47 1.0 8 AWG 89° 67° 53° 44° 13° 12° 10° 9°
65 1.5 6 AWG † † 74° 61° 18° 16° 14° 12°
65 1.5 6 AWG † † 74° 61° 18° 16° 14° 12°
87 2.5 3 AWG † † † 82° 25° 21° 19° 16°
87 2.5 3 AWG † † † 82° 25° 21° 19° 16°
130 2.5 1 AWG † † † † 37° 32° 28° 25°
130 2.5 1 AWG † † † † 37° 32° 28° 25°
173 2.5 2/0 AWG † † † † 49° 43° 38° 33°
173 2.5 2/0 AWG † † † † 49° 43° 38° 33°
59 2.5 6 AWG † † 83° 69° 21° 18° 16° 14°
59 2.5 6 AWG † † 83° 69° 21° 18° 16° 14°
68 2.5 4 AWG † † † 81° 24° 21° 19° 16°
68 2.5 4 AWG † † † 81° 24° 21° 19° 16°
98 2.5 3 AWG † † † † 35° 30° 27° 23°
98 2.5 3 AWG † † † † 35° 30° 27° 23°
TURN ON
(GPM)
RECOMMENDED
WIRE SIZE
(75° C/CU)
3.0
GPM
4.0
GPM
5.0
GPM
TEMPERATURE RISE °F
6.0
20.0
GPM
GPM
23.0
GPM
26.0
GPM
30.0
GPM
Electrical conguration and requirements
All Eemax three phase units are custom made to order and as such, are non-returnable and non-refundable. Check your electrical supply,
making sure all criteria for operating your Eemax water heater are met.
Eemax 600V, 480V and 208V Three Phase Units Delta Conguration
Requires: 3 Lives and 1 Ground (earth)
6
Information and product specications contained in this document are subject to change without notice. REV 2020-01