SpecAdvantage
™
For Commercial and Industrial Applications
Applications
•
Designed for low duty cycle applications where precise
temperature controls and low pressure drop are required
Performance Features
•
Designed for commercial and industrial applications
•
Capable of high volume and high temperature applications at
low duty cycle
•
Fully modulating - Predictive control algorithm and diverse safety
features ensures precise temperature control
•
T&P not required per UL499 (check local codes)
•
Thermo-Optical Sensor for infrared element monitoring
•
Field programmable, updatable rmware, and adjustable
Optional Features (NEMA cabinet required)
•
N4 (powder coated steel), N4X (304SS) N4X6 (316SS)
enclosures
•
Free standing legs
•
Freeze protection for harsh climate, up to -30°F
•
Non-fused or fused electrical disconnect
•
GFCI
•
Explosion proof – C1D2 Compliant, local certication required.
Class Z purge and pressurization system provided with pressure
switch for alarm controls. For classication other than C1D2
please contact the factory to discuss options.
•
Siren and beacon - audible and visual alarm (C1D2 compliant
when paired with explosion proof package)
Product Specications
Min. Operating Pressure: 35 PSI
Max. Operating Pressure: 150 PSI
Optimum Operating Pressure: 60-90 PSI
U.S. Patent #'s: US20140023354 and US20140178057
Installation Requirements
•
Properly sized water hammer arrestor
•
Minimum 35 PSI dynamic pressure at inlet
•
Sediment lter installed on inlet
Special Design Service
•
Inquiries for units for unique applications are welcome.
Call our Technical Service department at 1-800-543-6163.
•
Custom orders non-refundable
Information and product specications contained in this document are subject to change without notice. REV 2020-01
Specications
Tankless Electric Water Heater
*The wetted surface of this product
contacted by water contains less than
0.25% lead and meets NSF/ANSI 372
Suggested Specication
Tankless water heater shall be an Eemax SpecAdvantage model
number AP_________________________.
Optional factory installation in a ____(N4/N4X/N4X6) enclosure.
Enclosure to be tted with the following features:
_____ FP Freeze protection (-30°F)
_____ EDS Non-fused disconnect
_____ FDS Fused disconnect
_____ EP Explosion proof (C1D2 compliant)
_____ GFCI True RMS GFCI with digital display and reset
_____ SK 24" legs for free standing applications
_____ RD Remote display
_____ SB Siren and Beacon
_____ DC Dry contact
_____ ES Emergency stop - push button
Tankless water heater must have water connections on the
bottom, and be constructed with NSF 61 listed materials. Direct
heating element to be non-ferrous, cartridge style, designed for
eld replacement. Tankless water heater to utilize a dual PID
algorithm, actively managing power application to real-time system
demand. Integrated ow meter capable of volumes in excess of
30 GPM drives predictive control algorithm. Water heater must be
protected by redundant safeties. Redundant safeties to include
thermo mechanical safety switches, infrared element monitoring
via thermo optical sensors, and dual temperature monitoring via
primary control board. Tankless water heater user interface must
have the following capabilities:
•
Selectable display including Celsius/Fahrenheit, inlet
temperature, outlet temperature, ow rate, and setpoint
temperature.
•
Capable of displaying ow rate in gallons per minute or liters
per minute.
•
Diagnostic features to include error and fault code display.
•
Control board must maintain error/fault history of 9 events.
•
Capable of factory coded temperature setting (max. and min.)
•
Capable of rmware upgrades via USB port
•
Capable of BMS integration - contact factory
•
Compliant with ANSI Z358.1 tepid water without additional
mixing or purge features (inlet temperatures must not exceed
100°F when selecting an EE or EFD option)
9
SpecAdvantage
For Commercial and Industrial Applications
Specications
Tankless Electric Water Heater
Sux Denitions
S Sanitation. Shipped at 180°F
with temp range of 100°F-190°F
max.
EE Emergency Eyewash. Max.
outlet temperature 90°F. Conforms
to ANSI Z3581.1 tepid water
without additional mixing valve.
Shipped with display "Locked."
EFD Emergency Eye, Face &
Drench. Max. outlet temperature
90°F. Conforms to ANSI Z3581.1
tepid water without additional
mixing valve. Shipped with display
"Locked."
Note: Models with an EE or EFD sufx are not to
be fed to a thermostatic mixing valve. If a thermostatic mixing valve is required, heater of non EE or
EFD must be specied.
Note: Models without a sufx are set to a
maximum temperature of 140°F if the turn on is
greater than 1.5 GPM. Models with a 1.0 or 1.5
GPM turn on are limited to 120°F.
PHD Pressure Drop 63-150 kW
Flow Rate (GPM) Delta PSI
2 0
3 0
4 0
6 0
8 1
11 3
12 4
15 6
18 8
20 10
22 13
24 14
27 17
30 22
33 26
35 30
37 34
40 43
MODEL NUMBER
VOLTS 208 Three Phase Delta
AP032208
AP032208 EE
AP032208 S
AP036208
AP036208 EE
AP036208 S
AP041208
AP041208 EFD
AP041208 S
AP054208
AP054208 EFD
AP054208 S
AP064208
AP064208 EFD
AP064208 S
VOLTS 480 Three Phase Delta
AP036480
AP036480 EE
AP036480 S
AP039480
AP039480 EE
AP039480 S
AP048480
AP048480 EFD
AP048480 S
AP054480
AP054480 EFD
AP054480 S
AP063480
AP063480 EFD
AP063480 S
AP072480
AP072480 EFD
AP072480 S
AP096480
AP096480 EFD
AP096480 S
AP108480
AP108480 EFD
AP108480 S
AP126480
AP126480 EFD
AP126480 S
C
AP144480
C
AP144480 EFD
C
AP144480 S
VOLTS 600 Three Phase Delta
C
AP061600 EFD
C
AP071600 EFD
C
AP102600 EFD
C
AP130600 EFD
C
AP150600 EFD
* Units with a 1.0 or 1.5 GPM turn-on are limited to 120°F only. Contact Eemax support for applications above 120°F.
† Temperature electronically limited to factory preset temperature.
"C" indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No. 88.
** Contact Eemax for applications requiring lower turn on.
kW BTU/H
109,189
32
109,189
32
109,189
32
122,837
36
122,837
36
122,837
36
143,310
41
143,310
41
143,310
41
184,256
54
184,256
54
184,256
54
218,377
64
218,377
64
218,377
64
122,837
36
122,837
36
122,837
36
133,074
39
133,074
39
133,074
39
163,783
48
163,783
48
163,783
48
184,256
54
184,256
54
184,256
54
214,965
63
214,956
63
214,965
63
245,674
72
245,674
72
245,674
72
327,566
96
327,566
96
327,566
96
368,511
108
368,511
108
368,511
108
429,930
126
429,930
126
429,930
126
491,348
144
491,348
144
491,348
144
208,141
61
242,262
71
348,038
102
443,578
130
511,821
150
AMPS
PER
PHASE
89 1.0* 3 AWG 73° 55° 44° 36° 11° 10° 8° 7°
89 1.0 3 AWG † 55° 44° 36° 11° 10° 8° 7°
89 2.5** 3 AWG 73° 55° 44° 36° 11° 10° 8° 7°
100 1.0* 3 AWG 82° 61° 49° 41° 12° 11° 9° 8°
100 1.0 3 AWG † † 49° 41° 12° 11° 9° 8°
100 2.5** 3 AWG 82° 61° 49° 41° 12° 11° 9° 8°
113 1.0* 2 AWG 93° 70° 56° 47° 14° 12° 11° 9°
113 1.0 2 AWG † † 56° 47° 14° 12° 11° 9°
113 2.5** 2 AWG 93° 70° 56° 47° 14° 12° 11° 9°
150 1.5* 1/0 AWG † 92° 74° 61° 18° 16° 14° 12°
150 1.5 1/0 AWG † † † † 18° 16° 14° 12°
150 6.0** 1/0 AWG 123° 92° 74° 61° 18° 16° 14° 12°
178 2.5 3/0 AWG † 109° 87° 73° 22° 19° 17° 15°
178 2.5 3/0 AWG † † † † 22° 19° 17° 15°
178 6.0** 3/0 AWG 146° 109° 87° 73° 22° 19° 17° 15°
43 1.0* 8 AWG 82° 61° 49° 41° 12° 11° 9° 8°
43 1.0 8 AWG † † 49° 41° 12° 11° 9° 8°
43 2.5** 8 AWG 82° 61° 49° 41° 12° 11° 9° 8°
47 1.0* 8 AWG 89° 67° 53° 44° 13° 12° 10° 9°
47 1.0 8 AWG † † 53° 44° 13° 12° 10° 9°
47 2.5** 8 AWG 89° 67° 53° 44° 13° 12° 10° 9°
58 1.0* 6 AWG 109° 82° 66° 55° 16° 14° 13° 11°
58 1.0 6 AWG † † † 55° 16° 14° 13° 11°
58 2.5** 6 AWG 109° 82° 66° 55° 16° 14° 13° 11°
65 1.5* 6 AWG † 92° 74° 61° 18° 16° 14° 12°
65 1.5 6 AWG † † † † 18° 16° 14° 12°
65 2.5** 6 AWG 123° 92° 74° 61° 18° 16° 14° 12°
76 2.5 4 AWG † 108° 86° 72° 22° 19° 17° 14°
76 2.5 4 AWG † † † † 22° 19° 17° 14°
76 6.0** 4 AWG 143° 108° 86° 72° 22° 19° 17° 14°
87 2.5 3 AWG † † 98° 82° 25° 21° 19° 16°
87 2.5 3 AWG † † † † 25° 21° 19° 16°
87 6.0** 3 AWG † 123° 98° 82° 25° 21° 19° 16°
116 2.5 1 AWG † † † 109° 33° 29° 25° 22°
116 2.5 1 AWG † † † † 33° 29° 25° 22°
116 6.0** 1 AWG † † 131° 109° 33° 29° 25° 22°
130 2.5 1 AWG † † † † 37° 32° 28° 25°
130 2.5 1 AWG † † † † 37° 32° 28° 25°
130 6.0** 1 AWG † † 148° 123° 37° 32° 28° 25°
151 2.5 2/0 AWG † † † † 43° 37° 33° 29°
151 2.5 2/0 AWG † † † † 43° 37° 33° 29°
151 6.0** 2/0 AWG † † † 143° 43° 37° 33° 29°
173 2.5 2/0 AWG † † † † 49° 43° 38° 33°
173 2.5 2/0 AWG † † † † 49° 43° 38° 33°
173 6.0** 2/0 AWG † † † † 49° 43° 38° 33°
59 2.5 6 AWG † † † † 21° 18° 16° 14°
68 2.5 4 AWG † † † † 24° 21° 19° 16°
98 2.5 3 AWG † † † † 35° 30° 27° 23°
125 2.5 1 AWG † † † † 44° 39° 34° 30°
144 2.5 1/0 AWG † † † † 51° 45° 39° 34°
TURN ON
(GPM)
RECOMMENDED
WIRE SIZE
(75° C/CU)
3.0
GPM
4.0
GPM
5.0
GPM
TEMPERATURE RISE °F
6.0
20.0
GPM
GPM
23.0
GPM
26.0
GPM
30.0
GPM
Electrical conguration and requirements
All Eemax three phase units are custom made to order and as such, are non-returnable and non-refundable. Check your electrical supply,
making sure all criteria for operating your Eemax water heater are met.
Eemax 600V, 480V and 208V Three Phase Units Delta Conguration
Requires: 3 Lives and 1 Ground (earth)
10
Information and product specications contained in this document are subject to change without notice. REV 2020-01