AccuMix II
™
Thermostatic Heater Ideal for Sensor or Metering Faucets – UPC 407.3 Compliant
Applications
•
Handwashing
•
Lavatory sinks
•
Kitchen, bar, utility sinks
•
Ideal for sensor or metering faucets
Performance Features
•
Integrated mixing valve meets ASSE 1070
•
Unit meets UPC 407.3 requirements when properly installed
•
Self-diagnostics with intelligent controls actively protect heater in
installed environment
•
SafeStart™ technology engages upon start-up to help avoid
dry-re occurrence
•
Low activation with 0.3 GPM turn on ow
•
Digital LED display communicates system status and heater
operation feedback
•
Silent operation on all models except for AM012240T
•
Mounts in any orientation for a exible installation
•
Compact size ts almost anywhere; suitable for ADA compliant
facilities
•
Only one input line, hot or cold, needed for an easy installation
•
Designed to deliver hot water to a single pipe faucet or
mixing faucets
•
Integral 3/8" compression ttings; no soldering or sweat
connections required
•
No T&P relief valve needed (check local codes); Ready to go,
right out-of-the-box
•
Save water and time by installing unit at the point-of-use
•
Control system activates heater only on demand
•
High temperature limit switch enables safe operation
•
Active energy management with power modulation allows for
thermostatic accuracy
•
5-year limited warranty on leaks, 1-year on parts
Product Specications
Dimensions: 14.5" H x 5.25" W x 4" D
Weight: 5.5 lb
Cover: ABS-UL 94 5VA
Color: White
Temperature: Factory set to 105°F
Min. Dynamic Operating Pressure: 35 PSI
Max. Dynamic Operating Pressure: 150 PSI
Element: Replaceable nichrome cartridge insert
Fittings: 3/8" compression ttings
UL listed le number: E86887
U.S. Patent Pending Technology
Note: Mounting location must be located within 2 feet of xture. Over 2 feet, contact manufacturer.
Suggested Specication
Tankless water heater shall be an Eemax AccuMix II model
number AM___________.
Unit shall have ABS-UL 94 5VA rated cover. Unit shall have 0.3
GPM turn on. Unit shall allow mounting in any direction. Uses
ASSE 1070 approved integrated mixing valve to conform to
UPC 407.3. Element shall be replaceable cartridge insert. Unit
shall have replaceable lter in the inlet connector. Element shall
be iron free, Nickel Chrome material. Tankless water heater to
utilize complex algorithm, actively managing power application
to real time system demand. Integrated ow meter, along with
inlet and outlet temperature sensors provide data which allows
the unit to instantly adapt to variations in input parameters.
Heater shall be tted with 3/8" compression ttings to eliminate
need for soldering. Maximum operating pressure of 150 PSI.
Diagnostic features to include error/fault display. Hot water
storage tanks prohibited. Unit shall be Eemax or approved
equal.
Water Heater in
accordance with
NSF/ANSI 372
MH49688
Specications
Tankless Electric Water Heater
Special Design Service
Inquiries for units for unique applications are welcome.
Call our Technical Service department at 1-800-543-6163.
Information and product specications contained in this document are subject to change without notice. REV 2020-01
39
AccuMix II
Ideal for Sensor or Metering Faucets – UPC 407.3 Compliant
Specications
Electric Tankless Water Heater
Warning: The temperature of this
heater has been Eemax factory
set at 105°F for handwashing
applications and must not be
adjusted. Tampering with any
adjustments will void warranty and
may cause a loss of compliance to
Uniform Plumbing Code 407.3. For
further information please contact
our technical support department
at 1-800-543-6163.
RECOMMENDED
MODEL NUMBER kW AMPS
VOLTS 120
C
AM004120T
VOLTS 240*
C
AM005240T
AM005240T (derated 208V perf.)
C
AM007240T
AM007240T (derated 208V perf.)
C
AM010240T
AM010240T (derated 208V perf.)
C
AM012240T
AM012240T (derated 208V perf.)
VOLTS 277
AM004277T
AM008277T
AM010277T
* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a
208V to 240V single phase applied voltage. Check with local ofcials prior to derating the electrical infrastructure.
† Units are factory preset to 105°F.
"C" indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No. 88.
3.5 29 10 AWG 1 0.3 80° 48° 24° 16°
4.8 20 14 AWG 1 0.3 † 66° 33° 22°
3.6 17 14 AWG 1 0.3 † 49° 25° 16°
6.5 27 10 AWG 2 0.3 † † 44° 30°
5.0 24 10 AWG 2 0.3 † 68° 34° 23°
9.5 40 8 AWG 3 0.3 † † 65° 43°
7.5 36 8 AWG 3 0.3 † † 51° 34°
11.5 48 8 AWG 4 0.3 † † 79° 52°
8.7 42 8 AWG 4 0.3 † † 59° 40°
4.1 15 14 AWG 1 0.3 † 56° 28° 19°
8.0 29 10 AWG 2 0.3 † † 55° 36°
10.0 36 8 AWG 3 0.3 † † 68° 46°
WIRE SIZE
(75° C/CU)
# OF 0.5
AERATORS
SUPPLIED/UNIT
TURN ON
(GPM)
0.3
GPM
TEMPERATURE RISE °F
0.5
1.0
GPM
GPM
1.5
GPM
13.72
40
Information and product specications contained in this document are subject to change without notice. REV 2020-01