Edwards Signaling Series 100SB Pathfinder Installation Guide

Installation Instructions for Catalog Series 100SB
Pathfinder
Description and OperationDescription and Operation
Description and Operation
Description and OperationDescription and Operation
TM
Sealed Beam Rotating Lights
MaintenanceMaintenance
Maintenance
MaintenanceMaintenance
CAUTIONCAUTION
CAUTION
CAUTIONCAUTION
T o avoid injury , prior to disassembly , disconnect power from the unit.
Lamp Replacement
Electrical SpecificationsElectrical Specifications
Electrical Specifications
Electrical SpecificationsElectrical Specifications
Cat. Number Input Power Current
100SB*-N5 110V AC 60 Hz 0.88A
120V AC 60 Hz 1.04A 125V AC 60 Hz 1.14A
*The letter in this position of the catalog number signifies the color of the supplied dome: A - amber, B - blue, C - clear, G - green, or R - red.
InstallationInstallation
Installation
InstallationInstallation
CAUTIONSCAUTIONS
CAUTIONS
CAUTIONSCAUTIONS
Do not apply power to the unit until installation is completed and cover is secured.
When installing indoors, the signal may be mounted with the dome facing either directly up or down. For outdoor installation, the signal must be installed with the dome facing directly up.
Conduit Mounting
1. Route the 18" wiring leads from the 100SB through a 3/4" NPT conduit (not supplied) into a junction box. See Figure 1.
1. See Figure 1. Remove the screw in the clamp ring, remove the ring and lift off the dome.
2. Replace the appropriate lamp with a GE-4416-1 PAR 36 lamp.
3. Replace the dome and secure with the clamp ring and screw removed in step 1.
4. Apply power and ensure unit operates properly .
Cleaning
CAUTIONCAUTION
CAUTION
CAUTIONCAUTION
Abrasive materials or cleaners must not be used to clean the dome.
The signal's dome should be periodically cleaned to main­tain optimum light visibility. The dome may b e cleaned with a soft cloth or sponge using a mild detergent. Dry the dome thoroughly before replacing.
2. Connect the green ground wire to earth ground. Connect the black wire lead to the positive (+) power source lead and connect the white wire lead to neutral power source lead using wire nuts (not supplied).
3. Apply power and ensure unit operates properly .
Table 1. Replacement Parts
Cat. Number Description
Replacement Domes
100SB-LA Amber 100SB-LB Blue 100SB-LC Clear 100SB-LG Green 100SB-LR Red
Replacement Lamp
GE-4416-1 PAR 36 Replacement Lamp
P/N 3100424 ISSUE 1 © 2002
PAGE 1
Dome
Clamp Ring PVC Base
3/4" Conduit (not supplied)
Wiring (Black to positive (+), white to neutral and green to ground). Wire nuts not supplied.
Junction Box (not supplied)
Figure 1. Catalog Series 100SB Pathfinder
P/N 3100424 ISSUE 1 PAGE 2
Loading...