Edwards RV3, RV8, RV5, RV12, E2M18 Instruction Manual

...
Instruction Manual
ATEX Rotary Vane Pumps
A652-18-880
Issue C
AXXX-YY-ZZZ
Pump Variant Motor Description Type
XXX YY ZZZ
991 = 230 V 1 ph 50 Hz EExd 2B 992 = 400 V 3 ph 50 Hz EExd 2C 993 = 400 V 3 ph 50 Hz EExd 2B
E1M40 = 344 18 993 = 400 V 3 ph 50 Hz EExd 2B E2M40 = 364 E1M80 = 345 E2M80 = 365 E1M175 = 346 E2M175 = 366 E1M275 = 347 E2M275 = 367
This page has been intentionally left blank.
Declaration of Conformity
We, Edwards, Crawley Business Quarter, Manor Royal, Crawley, West Sussex, RH10 9LW, UK
declare under our sole responsibility, as manufacturer and person within the EU authorised to assemble the technical file, that the product(s)
RV3, RV5, RV8, RV12 ATEX Rotary Vacuum pumps:
A65X – 18 – ZZZ
Pump Type Motor Description X ZZZ 2 = RV3 985 = 115 V, 1 ph, 50 Hz, EExd IIC 3 = RV5 986 = 115 V, 1 ph, 60 Hz, EExd IIC 4 = RV8 989 = 230 V, 1 ph, 50 Hz, EExd IIC 5 = RV12 990 = 230 V, 1 ph, 60 Hz, EExd IIC 992 = 400 V, 3 ph, 50 Hz, EExd IIC
to which this declaration relates is in conformity with the following standard(s) or other normative document(s)
EN1012-2:1996, A1: 2009 Compressors and Vacuum Pumps. Safety Requirements. Vacuum Pumps EN13463-1: 2009 Non-electrical equipment for use in potentially explosive
atmospheres. Basic method and requirements
EN13463-5: 2003 Non-electrical equipment for use in potentially explosive
atmospheres. Protection by constructional safety ‘c’ EN60079-7:2007 Electrical apparatus for potentially explosive atmospheres. Increased safety ‘e’
and fulfils all the relevant provisions of 2006/42/EC Machinery Directive
2004/108/EC Electromagnetic Compatibility (EMC) Directive 94/9/EC ATEX Directive on use in Potentially Explosive Atmospheres
II 3 G c IIB T4 INTERNAL
II 2 G IIC T4 EXTERNAL Technical report MPTR0265
Note: This declaration covers all product serial numbers from the date this Declaration was
signed onwards.
05.10.12, Burgess Hill
Peter Meares, Technical Support Manager
This product has been manufactured under a quality system registered to ISO9001
Date and Place
D
P200-01-520 Issue
Declaration of Conformity
We, Edwards, Crawley Business Quarter, Manor Royal, Crawley, West Sussex, RH10 9LW, UK
declare under our sole responsibility, as manufacturer and person within the EU authorised to assemble the technical file, that the product(s)
E2M175 & E2M275 ATEX Rotary Vacuum pumps:
AXXX – 18 – ZZZ
Pump Type Motor Description XXX ZZZ
E2M175 = 366 993 = 400 V, 3 ph, 50 Hz, EExd IIB E2M275 = 367
to which this declaration relates is in conformity with the following standard(s) or other normative document(s)
EN1012-2:1996, A1: 2009 Compressors and Vacuum Pumps. Safety Requirements.Vacuum
Pumps EN13463-1: 2009 Non-electrical equipment for use in potentially explosive
atmospheres. Basic method and requirements EN13463-5: 2003 Non-electrical equipment for use in potentially explosive
atmospheres. Protection by constructional safety ‘c’ EN60079-7:2007 Electrical apparatus for potentially explosive atmospheres. Increased safety ‘e’
and fulfils all the relevant provisions of 2006/42/EC Machinery Directive
2004/108/EC Electromagnetic Compatibility (EMC) Directive 94/9/EC ATEX Directive on use in Potentially Explosive Atmospheres
II 3 G c IIB T3 INTERNAL
II 2 G IIB T160 EXTERNAL Technical report MPTR0265
Note: This declaration covers all product serial numbers from the date this Declaration was
signed onwards.
05.10.2012, Burgess HIll
Peter Meares, Technical Support Manager
This product has been manufactured under a quality system registered to ISO9001
Date and Place
P200-01-480 Issue C
Declaration of Conformity
We, Edwards, Crawley Business Quarter, Manor Royal, Crawley, West Sussex, RH10 9LW, UK
declare under our sole responsibility, as manufacturer and person within the EU authorised to assemble the technical file, that the product(s)
E2M40 & E2M80 ATEX Rotary Vacuum pumps:
AXXX – 18 – ZZZ
Pump Type Motor Description XXX ZZZ
E2M40 = 364 993 = 400 V, 3 ph, 50 Hz, EExd IIB E2M80 = 365
to which this declaration relates is in conformity with the following standard(s) or other normative document(s)
EN1012-2:1996, A1: 2009 Compressors and Vacuum Pumps. Safety Requirements.
Vacuum Pumps EN13463-1: 2009 Non-electrical equipment for use in potentially explosive
atmospheres. Basic method and requirements EN13463-5: 2003 Non-electrical equipment for use in potentially explosive
atmospheres. Protection by constructional safety ‘c’ EN60079-7:2007 Electrical apparatus for potentially explosive atmospheres. Increased safety ‘e’
and fulfils all the relevant provisions of 2006/42/EC Machinery Directive
2004/108/EC Electromagnetic Compatibility (EMC) Directive 94/9/EC ATEX Directive on use in Potentially Explosive Atmospheres
II 3 G c IIB T4 INTERNAL
II 2 G IIB T4 EXTERNAL Technical report MPTR0265
Note: This declaration covers all product serial numbers from the date this Declaration was
signed onwards.
05.10.2012, Burgess Hill
Peter Meares, Technical Support Manager
This product has been manufactured under a quality system registered to ISO9001
Date and Place
D
P200-01-080 Issue
Declaration of Conformity
We, Edwards, Crawley Business Quarter, Manor Royal, Crawley, West Sussex, RH10 9LW, UK
declare under our sole responsibility, as manufacturer and person within the EU authorised to assemble the technical file, that the product(s)
E1M18 & E2M18 ATEX Rotary Vacuum pumps:
AXXX – 18 – ZZZ
Pump Type Motor Description XXX ZZZ
E1M18 = 343 987 = 115 V, 1 ph, 60 Hz, EExd IIB E2M18 = 363 988 = 220 V, 1 ph, 60 Hz, EExd IIB 991 = 230 V, 1 ph, 50 Hz, EExd IIB 993 = 400 V, 3 ph, 50 Hz, EExd IIB
to which this declaration relates is in conformity with the following standard(s) or other normative document(s)
EN1012-2:1996, A1: 2009 Compressors and Vacuum Pumps. Safety Requirements.
Vacuum Pumps EN13463-1: 2009 Non-electrical equipment for use in potentially explosive
atmospheres. Basic method and requirements EN60079-7:2007 Electrical apparatus for potentially explosive atmospheres. Increased safety ‘e’ EN13463-5: 2003 Non-electrical equipment for use in potentially explosive
atmospheres. Protection by constructional safety ‘c’ and fulfils all the relevant provisions of 2006/42/EC Machinery Directive
2004/108/EC Electromagnetic Compatibility (EMC) Directive 94/9/EC ATEX Directive on use in Potentially Explosive Atmospheres
II 3 G c IIB T4 INTERNAL
II 2 G IIB T4 EXTERNAL Technical report MPTR0265
Note: This declaration covers all product serial numbers from the date this Declaration was
signed onwards.
05.10.2012, Burgess Hill
Peter Meares, Technical Support Manager
This product has been manufactured under a quality system registered to ISO9001
Date and Place
D
P200-01-040 Issue
Declaration of Conformity
We, Edwards, Crawley Business Quarter, Manor Royal, Crawley, West Sussex, RH10 9LW, UK
declare under our sole responsibility, as manufacturer and person within the EU authorised to assemble the technical file, that the product(s)
E1M18 & E2M18 ATEX Rotary Vacuum pumps:
AXXX – 18 – ZZZ
Pump Type Motor Description XXX ZZZ
E1M18 = 343 985 = 115 V, 1 ph, 50 Hz, EExd IIC E2M18 = 363 986 = 115 V, 1 ph, 60 Hz, EExd IIC 989 = 230 V, 1 ph, 50 Hz, EExd IIC 990 = 230 V, 1 ph, 60 Hz, EExd IIC 992 = 400 V, 3 ph, 50 Hz, EExd IIC
to which this declaration relates is in conformity with the following standard(s) or other normative document(s)
EN12100: 2010 Safety of machinery. General principles for design.
Risk assessment and risk reduction EN61010-1: 2010 Safety Requirements for Electrical Equipment for Measurement,
Control and Laboratory Use. General Requirements EN1012-2:1996, A1: 2009 Compressors and Vacuum Pumps. Safety Requirements.
Vacuum Pumps EN13463-1: 2009 Non-electrical equipment for use in potentially explosive
atmospheres. Basic method and requirements EN60079-7:2007 Electrical apparatus for potentially explosive atmospheres. Increased safety ‘e’ EN13463-5: 2003 Non-electrical equipment for use in potentially explosive
atmospheres. Protection by constructional safety ‘c’ EN60034-1: 2004 Rotating electrical machines. Rating and performance
and fulfils all the relevant provisions of 2006/42/EC Machinery Directive
2004/108/EC Electromagnetic Compatibility (EMC) Directive 94/9/EC ATEX Directive on use in Potentially Explosive Atmospheres
II 3 G c IIB T4 INTERNAL
II 2 G IIC T4 EXTERNAL Technical report MPTR0265
Note: This declaration covers all product serial numbers from the date this Declaration was
signed onwards.
05.10.2012, Burgess HIll
Peter Meares, Technical Support Manager
This product has been manufactured under a quality system registered to ISO9001
Date and Place
D
P200-01-500 Issue
Declaration of Conformity
We, Edwards, Crawley Business Quarter, Manor Royal, Crawley, West Sussex, RH10 9LW, UK
declare under our sole responsibility, as manufacturer and person within the EU authorised to assemble the technical file, that the product(s)
RV3, RV5, RV8 & RV12 ATEX Rotary Vacuum pumps:
AXXX – 18 – ZZZ
Pump Type Motor Description XXX ZZZ
RV3 = 652 987 = 115 V, 1 ph, 60 Hz, EExd IIB RV5 = 653 988 = 220 V, 1 ph, 60 Hz, EExd IIB RV8 = 654 991 = 230 V, 1 ph, 50 Hz, EExd IIB RV12 = 655 993 = 400 V, 3 ph, 50 Hz, EExd IIB
to which this declaration relates is in conformity with the following standard(s) or other normative document(s)
EN1012-2:1996, A1: 2009 Compressors and Vacuum Pumps. Safety Requirements.
Vacuum Pumps EN13463-1: 2009 Non-electrical equipment for use in potentially explosive
atmospheres. Basic method and requirements EN60079-7:2007 Electrical apparatus for potentially explosive atmospheres. Increased safety ‘e’ EN13463-5: 2003 Non-electrical equipment for use in potentially explosive
atmospheres. Protection by constructional safety ‘c’ and fulfils all the relevant provisions of 2006/42/EC Machinery Directive
2004/108/EC Electromagnetic Compatibility (EMC) Directive 94/9/EC ATEX Directive on use in Potentially Explosive Atmospheres
II 3 G c IIB T4 INTERNAL
II 2 G IIB T4 EXTERNAL Technical report MPTR0265
Note: This declaration covers all product serial numbers from the date this Declaration was
signed onwards.
05.10.2012, Burgess HIll
Peter Meares, Technical Support Manager
This product has been manufactured under a quality system registered to ISO9001
Date and Place
D
P200-01-060 Issue
A652-18-880 Issue C

Contents

Section Page
1 Introduction .......................................................................................1
1.1 Scope and definitions ................................................................................................... 1
1.2 ATEX directive implications ............................................................................................ 1
1.3 Description ................................................................................................................ 2
1.4 ATEX certification ....................................................................................................... 3
2 NORMAL OPERATION .............................................................................5
3 ABNORMAL OPERATION ... .... ..... ..... ..... ..... ..... ..... .....................................7
4 SYSTEM DATA ......................................................................................9
4.1 Physical data ............................................................................................................. 9
4.1.1 Dimensions ................................................................................................................9
4.1.2 Mass ........................................................................................................................ 9
4.2 Mechanical data .......................................................................................................... 9
4.3 Operating conditions ...................................................................................................10
4.4 Noise data ................................................................................................................10
4.5 Vibration data ...........................................................................................................10
4.6 Electrical data ...........................................................................................................10
4.6.1 Electrical data: single-phase pumps .................................................................................10
4.6.2 Electrical data: three-phase pumps .................................................................................11
Contents
5 INSTALLATION ................................................................................... 13
5.1 Safety ..................................................................................................................... 13
5.2 Mechanical installation ................................................................................................14
5.3 Electrical installation ..................................................................................................14
5.3.1 Check and configure the motor: single and three phase pumps ................................................15
5.3.2 Connect the pump to your electrical supply .......................................................................15
5.3.3 Connection of additional thermal protection devices ............................................................16
5.3.4 Check the direction of rotation ......................................................................................16
6 OPERATION ...................................................................................... 17
6.1 Pumping flammable/pyrophoric materials .........................................................................17
6.2 Gas purges ...............................................................................................................18
6.3 Shut down procedure ...................................................................................................18
6.4 Manual reset .............................................................................................................18
7 MAINTENANCE ................................................................................... 19
7.1 Safety information ......................................................................................................19
7.2 Maintenance plan .......................................................................................................19
7.3 Control intervals of ATEX coupling insert (EM40/80/175/275) ..................................................20
8 SERVICE, SPARES ................................................................................ 21
Index ........................................................... ................................... 23
For return of equipment, complete the HS Forms at the end of this manual.
Falcon 04069 04/2008
© Edwards Limited 2008. All rights reserved. Page i Edwards and the Edwards logo are trademarks of Edwards Limited.
A652-18-880 Issue C
Contents

Tables

Table Page
1 ATEX certification ....................................................................................................... 3
2 Overall length ............................................................................................................ 9
3 Pump mass ................................................................................................................9
4 Noise data ................................................................................................................10
5 Electrical data (single-phase pumps) ................................................................................10
6 Electrical data (three-phase pumps) ................................................................................11
7 Cable gland reference .................................................................................................15
8 Torque settings ..........................................................................................................20

Associated publications

Publication title Publication number
Vacuum pump and vacuum system safety P300-20-000 Vacuum systems safety booklet P400-40-100 British Autoguard Samiflex coupling installation/maintenance instructions Flameproof motor maintenance instructions
Page ii © Edwards Limited 2008. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
A652-18-880 Issue C

1Introduction

1.1 Scope and definitions

This manual provides installation, operation and maintenance instructions for Group 2 Category 2 ATEX pumps in respect to ignition sources external to the pump and Group 2 Category 3 ATEX pumps in respect to ignition sources internal to the pump. You must use the pumps as specified in this manual.
Read this manual before you install and operate your rotary vacuum pump. Important safety information is highlighted as WARNING and CAUTION instructions; you must obey these instructions. The use of WARNINGS and CAUTIONS is defined below.
WARNING
Warnings are given where failure to observe the instruction could result in injury or death to people.
CAUTION
Cautions are given where failure to observe the instruction could result in damage to the pump, associated equipment and process.
Introduction
The units used throughout this manual conform to the SI international system of units of measurement.
Note: The content of this manual may change from time to time without notice. Edwards accept no liability for
any errors that may appear in this manual, nor does it make any expressed or implied warranties regarding the content. So far as is reasonably practicable Edwards has ensured that its products have been designed and constructed so as to be safe and without risks when properly installed and used in accordance with Edwards Operating Instructions. Edwards accepts no liability for loss of profit, loss of market or any other indirect or consequential loss whatsoever.
Note: Product warranty and limit of liability are dealt with in Edwards standard terms and conditions of sale or
negotiated contract under which this document is supplied.

1.2 ATEX directive implications

This pump is designed to meet the requirements of Group II Category 2 equipment in respect of potential ignition sources external to the pump, and also Group II Category 3 in respect to ignition sources internal to the pump. This classification is in accordance with Directive 94/9/EC of the European Parliament and the Council of 23rd March 1994 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres. (The ATEX Directive)
There is no potential source of ignition within or external to the pump during normal operation but there may be potential sources of ignition under conditions of rare or expected malfunction as defined in the Directive. As a result of this, it is necessary to consider the potential consequences of ignition sources occurring under rare or expected malfunction. (Ref ATEX137 1992/92/EC).
© Edwards Limited 2008. All rights reserved. Page 1 Edwards and the Edwards logo are trademarks of Edwards Limited.