Description Item Number
ASG-1000-1/8 NPT D357-25-000
ASG-1000-NW16 D357-26-000
ASG-2000-1/8 NPT D357-27-000
ASG-2000-NW16 D357-28-000
Contents
D357-25-880 Issue E
Contents
Section Page
1 Introduction ....................................................................................... 1
1.1 Scope of this manual .................................................................................................... 1
1.2 Description ................................................................................................................ 1
1.3 Gas dependency .......................................................................................................... 1
2 Technical data .................................................................................... 3
2.1 Mechanical data .......................................................................................................... 3
2.2 Performance, operation and storage conditions .................................................................... 3
2.3 Electrical data ............................................................................................................ 4
2.4 Material exposed to vacuum ........................................................................................... 4
3 Installation ......................................................................................... 5
3.1 Unpack and inspect ...................................................................................................... 5
3.2 Fit the ASG to the vacuum system .................................................................................... 5
3.3 Electrical connections ................................................................................................... 5
3.3.1 Connect to Edwards controller ........................................................................................ 5
3.3.2 Connect to your own supply and control equipment ............................................................... 5
4 Operation .......................................................................................... 9
4.1 Pressure measurement .................................................................................................. 9
5 Maintenance ..................................................................................... 11
5.1 Zero adjustment ........................................................................................................11
5.2 Cleaning ..................................................................................................................11
6 Storage and disposal ........................................................................... 13
6.1 Storage ...................................................................................................................13
6.2 Disposal ...................................................................................................................13
7 Spares and accessories ......................................................................... 15
7.1 Introduction .............................................................................................................15
7.2 Accessories ...............................................................................................................15
For return of equipment, complete the HS Forms at the end of this manual.
Illustrations
Figure Page
1 General view of NW16 version active strain gauge ................................................................. 2
2 Dimensions of active strain gauge ..................................................................................... 4
3 Pins on the ASG electrical connector socket ........................................................................ 6
4 Pins on the ASG adapter cable socket ................................................................................ 6
5 Schematic diagram of typical electrical connections using 4 pin DIN connector .............................. 7
6 Schematic diagram of typical electrical connections using FCC68 connector .................................. 7
dcs/7822/12/07
D357-25-880 Issue E
Page ii © Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Contents
Tables
Table Page
1 Zeroing pressure ........................................................................................................11
© Edwards Limited 2007. All rights reserved. Page 1 Edwards and the Edwards logo are trademarks of Edwards Limited.
Introduction
D357-25-880 Issue E
1Introduction
1.1 Scope of this manual
This manual provides installation, operation and maintenance instructions for the Edwards ASG (Active Strain Gauge). You must use the ASG as specified in this manual.
Read this manual before you install and operate the ASG. Important safety information is highlighted as WARNING and CAUTION instructions; you must obey these instructions. The use of WARNINGS and CAUTIONS is defined below.
CAUTION
Cautions are given where failure to observe the instruction could result in damage to the equipment, associated equipment or process.
The unit used through this manual conforms to the SI international system of units of measurement.
The following symbols appear on the ASG:
1.2 Description
The ASG, shown in Figure 1, is a strain gauge and gauge controller in a single compact unit. The measurement range of the ASG-1000 is 1000 to 1 mbar. The range of the ASG-2000 is 2000 to 1 mbar.
The ASG requires a 13.5 to 36 V d.c. power supply: it has a 0 to 10 V d.c. linear analogue output which is related to pressure. The ASG is compatible with all of the Edwards AGCs (Active Gauge Controllers) and with the ADD (Active Digital Display). Alternatively, you can use an independent power supply for the ASG and can read the ASG output signal with a voltmeter or an analogue-to-digital converter. A standard Active gauge cable plus an ASG adapter cable are used to connect the ASG to an AGC or ADD. These are available as accessories (refer to Section 7.2). To connect to an electrical supply and voltmeter, the 4-way connector on the gauge head can be used.
A gauge identification signal is incorporated in the adapter cable : thi s is used by Ed ward s AG Cs to iden tif y whi ch ty pe of active gauge is connected.
1.3 Gas dependency
The pressure sensing technique depends on the deflection of a stainless steel diaphragm. The measurement is therefore completely independent of gas type.
WARNING
Warnings are given where failure to observe the instruction could result in injury or death to persons.
Warning - refer to accompanying documentation.
From August 2005, Edwards will offer European customers a recycling service.
D357-25-880 Issue E
Page 2 © Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Introduction
Figure 1 - General view of NW16 version active strain gauge
Loading...
+ 14 hidden pages