EdgeStar IB120SS User Manual

IB120SS Undercounter Ice Maker
This owners manual provides instructions on safe installation, use, and maintenance. Please read it carefully and save it for reference.
http://www.edgestar.com
IMPORTANT SAFETY INSTRUCTIONS
aWARNINGa
FOLLOW
THESE BASIC PRECAUTIONS TO
REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY WHEN USING YOUR ICE MAKER.
DANGER:
CHILD ENTRAPMENT AND SUFFOCATION ARE NOT PROBLEMS OF THE PAST. JUNKED OR ABANDONED APPLIANCES ARE STILL DANGEROUS.
ALL INSTRUCTIONS BEFORE USING THE ICE MAKER.
READ
RISK OF CHILD ENTRAPMENT.
BEFORE
NEVER
YOU THROW AWAY YOUR ICE MAKER: TAKE OFF THE DOOR.
ALLOW CHILDREN TO OPERATE, PLAY WITH, OR CRAWL INSIDE THE
APPLIANCE.
NEVER
CLEAN ICE MAKER PARTS WITH FLAMMABLE FLUIDS. THE FUMES CAN
CREATE A FIRE HAZARD OR EXPLOSION.
NOT STORE OR USE GASOLINE OR ANY OTHER FLAMMABLE VAPORS AND LIQUIDS
DO IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. THE FUMES CAN CREATE A FIRE HAZARD OR EXPLOSION.
INSTALLATION INSTRUCTIONS
¾ BEFORE USING YOUR ICE MAKER
REMOVE
CHECK
1
1
1
1
BEFORE
FOR APPROXIMATELY 2 HOURS. THIS WILL REDUCE THE POSSIBILITY OF A MALFUNCTION IN THE COOLING SYSTEM FROM HANDLING DURING TRANSPORTATION.
CLEAN
¾ INSTALLATION OF YOUR ICE MAKER
THIS APPLIANCE IS DESIGNED TO VENT HOT AIR THROUGH THE FRONT VENT. THIS ALLOWS FOR INSTALLATION IN A RECESSED OR BUILT-IN APPLICATION, IF DESIRED.
• PLACE YOUR ICE MAKER ON A LEVEL SURFACE THAT IS STRONG ENOUGH TO SUPPORT THE ICE MAKER WHEN IT IS FULLY LOADED. REMEMBER THAT THE UNIT WILL BE SIGNIFICANTLY HEAVIER ONCE IT IS OPERATIONAL AND FULLY LOADED. LEVEL YOUR ICE MAKER BY ADJUSTING THE LEGS AT THE FRONT OF THE ICE MAKER.
LOCATE HEATER, RADIATOR, ETC.). DIRECT SUNLIGHT MAY AFFECT THE FINISH AND HEAT SOURCES MAY INCREASE ELECTRICAL CONSUMPTION. EXTREME COLD AMBIENT TEMPERATURES MAY ALSO CAUSE THE ICE MAKER MALFUNCTION. THIS ICE MAKER IS DESIGNED FOR INSTALLATION INDOORS IN “ROOM TEMPERATURE” AMBIENT CONDITIONS.
AVOID AIR WILL CAUSE FROST TO FORM QUICKLY ON THE EVAPORATOR REQUIRING FREQUENT DEFROSTING.
PLUG OUTLET. DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD. ANY QUESTIONS CONCERNING POWER AND/OR GROUNDING SHOULD BE DIRECTED TOWARD A CERTIFIED ELECTRICIAN.
THE EXTERIOR AND INTERIOR PACKING.
TO BE SURE YOU HAVE ALL OF THE FOLLOWING PARTS: ICE BUCKET PLASTIC SCOOP HOSE, 25 FT. INSTRUCTION MANUAL
CONNECTING THE ICE MAKER TO THE POWER SOURCE, LET IT STAND UPRIGHT
THE INTERIOR SURFACE WITH LUKEWARM WATER USING A SOFT CLOTH.
THE ICE MAKER AWAY FROM DIRECT SUNLIGHT AND SOURCES OF HEAT (STOVE,
LOCATING THE ICE MAKER IN MOIST/HUMID AREAS. TOO MUCH MOISTURE IN THE
THE ICE MAKER INTO AN EXCLUSIVE PROPERLY INSTALLED GROUNDED WALL
1
¾ ELECTRICAL CONNECTION
IMPROPER USE OF THE GROUNDED PLUG CAN RESULT IN THE RISK OF ELECTRICAL SHOCK. IF THE POWER CORD IS DAMAGED, HAVE IT REPLACED BY AN AUTHORIZED SERVICER.
aWARNINGa
• THIS ICE MAKER SHOULD BE PROPERLY GROUNDED FOR YOUR SAFETY. THE POWER CORD OF THIS ICE MAKER IS EQUIPPED WITH A THREE-PRONG PLUG WHICH MATES WITH STANDARD THREE PRONG WALL OUTLETS TO MINIMIZE THE POSSIBILITY OF ELECTRICAL SHOCK.
DO
DO
DO
IF
THIS
THE
¾ EXTENSION CORD BECAUSE OF POTENTIAL SAFETY HAZARDS, THIS APPLIANCE IS NOT RECOMMENDED FOR USE WITH AN EXTENSION CORD. HOWEVER, IF YOU MUST USE AN EXTENSION CORD, USE ONLY A UL/CUL-LISTED, 3-WIRE GROUNDING TYPE APPLIANCE EXTENSION CORD WITH A GROUNDING TYPE PLUG AND OUTLET. THE ELECTRICAL RATING OF THE CORD MUST BE 115 VOLTS AND AT LEAST 10 AMPS.
¾ CONNECTING
ALL
CONNECT
POSITION
WIPE
NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE THIRD GROUND PRONG
FROM THE POWER CORD SUPPLIED.
NOT USE AN EXTENSION CORD TO CONNECT POWER TO THE UNIT. NOT USE A TWO-PRONG GROUNDING ADAPTER.
YOU ONLY HAVE A TWO-PRONG WALL RECEPTACLE, CONTACT A QUALIFIED
ELECTRICIAN TO HAVE IT REPLACED WITH A 3-PRONG RECEPTACLE IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES.
ICE MAKER REQUIRES A STANDARD 115 VOLTS A.C. 60HZ ELECTRICAL OUTLET WITH
THREE-PRONG GROUND.
CORD SHOULD BE SECURED BEHIND THE ICE MAKER AND NOT LEFT EXPOSED OR
LOOSE.
THE WATER SUPPLY
aWARNINGa
IMPROPER WATER LINE CONNECTION MAY RESULT IN FLOODING
YOU MUST USE A LICENSED PLUMBER
REVIEW STATE AND LOCAL PLUMBING CODES BEFORE INSTALLATION
THE NECESSARY HARDWARE IS NOT PROVIDED (AS THE PLUMBING FIXTURES AT
THE INSTALLATION POINT MAY DIFFER) FOR INSTALLATION SO IT IS NECESSARY TO HIRE A PROFESSIONAL LICENSED PLUMBER TO COMPLETE THE INSTALLATION.
TUBING (SUPPLIED WITH UNIT) TO THE NEAREST COLD WATER SOURCE.
CONNECT SUFFICIENT TUBING TO THE UNIT TO ALLOW THE APPLIANCE TO BE MOVED FREELY FOR CLEANING AND SERVICE. ALSO MAKE SURE THAT THE TUBING IS NOT PINCHED OR DAMAGED DURING TRANSPORTATION/INSTALLATION.
UNIT TO ALLOW FREE AIRFLOW THROUGH THE FRONT
GRILL (SEE FIGURE 1).
OUT INSIDE OF UNIT AND ICE BUCKET WITH A DAMP CLOTH.
FIGURE 1
2
Loading...
+ 6 hidden pages