Edge Lighting Dual Feed Surface Mount Magnetic Transformer User Manual

© 2013 Edge Lighting. All Rights Reserved.
Chicago, IL 60614
Tel: 773-770-1195
Fax: 773-935-5613 www.edgelighting.com info@edgelighting.com
M2T-2X150-12-_
904-M2T-2X150-12-06
Installation Instructions for Monorail 2 Circuit 2 X 150
Mount Magnetic Transformer
120 Volt Input to 12 Volt Single
Watt Surface
Feed Output
SAVE THESE INSTRUCTIONS!
GENERAL INFORMATION IMPORTANT SAFETY INSTRUCTIONS
- RISK OF FIRE: This product must be installed by a qualified electrician. Turn the power to the electrical box off during installation. Read the "Important Safety Instructions" before installation.
- This product is suitable only for indoor dry locations and approved for the use at any height above the finished floor.
- This product contains a magnetic transformer with a built-in dimming coil.
- Do not install this lighting system in a damp or wet location.
- Do not conceal or extend bus bar conductor through building wall.
- To reduce the risk of fire and burns, do not install this lighting system where the insulated open bus bar conductors can be shorted or contact any conductive materials.
- This product may be dimmed only with a low voltage magnetic dimmer. Using a dimmer other than specified may work initially, but will eventually cause transformer failure and void the warranty. The dimmer must be derated as indicated by the dimmer manufacturer.
- A typical installation is shown. Specific installation must be in accordance with the local electrical codes.
- Load each circuit of the surface mount transformer to MAXIMUM 150 Watt.
- To reduce the risk of the system overheating and possibly causing a fire, make sure all the connections are tight.
- Do not install fixture assemblies closer than six inches, or as specified in the fixture installation instructions, to curtains or similarly combustible materials.
- Turn the electrical power off before modifying the lighting system in any way.
- The fixtures used with the Edge Lighting systems must be identified for use with the corresponding Edge Lighting systems.
- Minimum volume of the electrical box must be 6 cubic inches (98 cubic centimeters).
- The system is "ETL" listed for USA and Canada only when all the products used are supplied by Edge Lighting.
1
Install the Surface Mount Transformer
A
1
2: Unhook the transformer cover from the set screw and
remove it from the transformer housing.
CROSSBAR
C
ASSEMBLY
M4 BUTTON HEAD SCREW
1
3
2MM ALLEN WRENCH
1
COVER
1: Loosen and remove the five M4 button head screws around the transformer cover with the provided 2mm Allen wrench.
SET SCREW
B
HOUSING
2
COVER
3: Remove the inside nut and washer to remove the crossbar assembly. DO NOT DISASSEMBLE THE CROSSBAR
ASSEMBLY.
INSIDE NUT
The 120 volt transformer wires must be connected to the
NOTE:
same phase of 120 volt power wires.
4: Connect one set of provided white and black extension wires to the neutral and hot power wires coming from a switch respectively with the wire nuts provided.
5: Connect the other set of provided white and brown extension wires to the neutral and hot power wires coming from the other switch respectively with the wire nuts provided.
6: Feed the extension wires through the crossbar assembly nipple.
7: Place all wires and wire nut connections inside the electrical box.
8: Mount the crossbar assembly to the electrical box with the two provided #8-32 screws.
9: Make sure the crossbar assembly is grounded in accordance with local electrical codes.
WASHER
D
4
#8-32 SCREW
EXTENSION WIRES
9
7
8
6
CROSSBAR ASSEMBLY NIPPLE
2
Loading...
+ 2 hidden pages