Ecodyne Water Systems TB-RO, True Blue TB-RO Installation And Operation Manual

Page 1
Model TB-RO
How to install, operate
and maintain your Reverse Osmosis
TM
Drinking Water System
If you have any questions about system
operation or maintenance, call toll free:
1-800-689-4571
Monday - Friday, 8:30 am - 6:00 pm EST
or Saturday 9:00 am - 3:00 pm EST
or visit us online at:
www.truebluewatersolutions.com
When you call, please be prepared to provide
the model, date code and serial number of your
product, found on the rating decal, located on
the back of the top cover.
System tested and certified by NSF International
against NSF/ANSI Standards 42 & 58.
See performance data sheet for details.
Installation and Operation Manual
Manufactured for Defender Security Company by
Ecodyne Water Systems
1890 Woodlane Drive Woodbury, MN 55125
Printed on recycled paper
Page 2
TABLE OF CONTENTS
Page
Specifications & Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Inspect Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Tools Needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Plan Your Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Overview & Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-16
How Your Reverse Osmosis System Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-18
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-20
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Exploded View & Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23
ONE YEAR LIMITED WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM
(Except filter cartridges and R.O. membrane)
Warrantor: Defender Security Company, dba True Blue Water Solutions, 3750 Priority Way South, Suite 200,
Indianapolis, IN 46240
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Warrantor warrants, to the original owner, that the Reverse Osmosis Drinking Water System, when installed and main­tained in accordance with the instructions, will be free from defects in materials and workmanship for a period of one (1) year from date of installation.
● For a period of one (1) year from the date of installation, all parts will be free from defects in materials and workman­ship and will perform their normal functions.
● For a period of ninety (90) days from the date of installation, labor to repair or replace any part deemed to be defec­tive in materials or workmanship, will be provided at no additional cost.
If, within the first year, a part proves, after inspection, to be defective, Warrantor will, at its sole option, either replace or repair the part without charge except normal shipping (and installation charges upon expiration of the 90 day labor warran­ty). Labor to maintain the equipment is not part of the warranty after the first ninety (90) days. Filters and membranes, which are expendable, are not covered by the warranty.
If you have questions regarding a warranted product, need assistance with installation or troubleshooting, wish to order a part or report a warranty issue, we are just a phone call away. SIMPLY DIAL 1-800-689-4571, Monday - Friday, 8:30 am ­6:00 pm EST, or Saturday 9:00 am - 3:00 pm EST, for assistance. This warranty applies only while this product is in use in the United States.
General Provisions
The above warranties are effective provided the Reverse Osmosis Drinking Water System is operated at water pressures not exceeding 125 psi, and at water temperatures not exceeding 100°F; provided further that the Reverse Osmosis Drinking Water System is not subject to abuse, misuse, neglect, freezing, accident or negligence; and provided further that the Reverse Osmosis Drinking Water System is not damaged as the result of any unusual force of nature such as, but not limited to, flood, hurricane, tornado or earthquake. This warranty is void if the product is repaired, modified or altered, unless such repair, modification or alteration is expressly authorized by the Warrantor in writing.
Warrantor is excused if failure to perform its warranty obligations is the result of strikes, government regulation, materials shortages, or other circumstances beyond its control.
THERE ARE NO WARRANTIES ON THE REVERSE OSMOSIS DRINKING WTAER SYSTEM BEYOND THOSE SPECIFI­CALLY DESCRIBED ABOVE. ALL IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MER­CHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE, ARE DISCLAIMED TO THE EXTENT THEY MIGHT EXTEND BEYOND THE ABOVE PERIODS. THE SOLE OBLIGATION OF WARRANTOR UNDER THESE WARRANTIES IS TO REPLACE OR REPAIR THE COMPONENT OR PART WHICH PROVES TO BE DEFECTIVE WITHIN THE SPECI­FIED TIME PERIOD, AND WARRANTOR IS NOT LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, LOSS OF OTHER GOODS OR ASSOCIATED EQUIPMENT OR DAMAGES TO ANY ASSOCIATED EQUIPMENT, VALUE OF THIS WARRANTY SHALL NOT EXCEED THE PRICE PAID BY YOU FOR THE EQUIPMENT. NO WARRANTOR AGENT, REPRESENTATIVE, OR OTHER PERSON IS AUTHORIZED TO EXTEND OR EXPAND THE WARRANTIES EXPRESSLY DESCRIBED ABOVE.
Some states do not allow limitations on how long an implied warranty lasts or exclusions or limitations of incidental or consequential damage, so the limitations and exclusions in this warranty may not apply to you. This warranty applies to consumer-owned installations only.
Manufactured by Ecodyne Water Systems, 1890 Woodlane Drive, Woodbury, MN 55125,
for Defender Security Company, 3750 Priority Way South Drive, Suite 200, Indianapolis, IN 46240.
2
Page 3
Specifications & Dimensions
11-3/8" 3-1/2"
13"
14"
9" dia.
Supply water pressure limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-100 psi (280-689 kPa)
Supply water temperature limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-100 °F (4.5-37.7°C)
Maximum total dissolved solids (TDS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 ppm
Maximum water hardness @ 6.9 pH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 gpg
Maximum iron, manganese, hydrogen sulfide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
Chlorine in water supply (max. ppm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0
Supply water pH limits (pH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Product (quality) water, 24 hours1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.4 gal. (69.6 liters)
Percent rejection of TDS, minimum (new membrane)1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68.5
Automatic shutoff control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . yes
Efficiency2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.2 %
Recovery3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22.9 %
This system conforms to NSF/ANSI 58 for the specific performance claims as verified and substantiated by test data.
1
@ Feed water supply at 50 psi, 77°F, and 750 TDS --- Quality water production, amount of waste water and percent rejection all vary with changes in pressure, temperature and total dissolved solids.
2
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treat­ed water under operating conditions that approximate typical daily usage.
3
Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
Non-potable Water Sources: Do not attempt to use this product to make safe drinking water from non-potable water sources. Do not use the system on microbiologically unsafe water, or water of unknown quality without an adequate disinfection before or after the system. This system is certified for cyst reduction and may be used on disinfected water that may contain filterable cysts.
Arsenic Reduction: This system shall only be used for arsenic reduction on chlorinated water supplies containing detectable residual free chlorine at the system inlet. Water systems using an inline chlorinator should provide a one minute chlorine contact time before the reverse osmosis system.
Nitrate/Nitrite Test Kit: This system is acceptable for treatment of influent concentrations of no more than 27mg/L nitrate and 3mg/L nitrite in combination measured as N. It is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater. This system is supplied with a nitrate/nitrite test kit. Product water should be monitored periodically according to the instructions provided with the test kit.
Product Water Testing: The Reverse Osmosis system contains a replaceable treatment component critical for the effective reduction of total dissolved solids. Product water should be tested periodically to verify that the system is performing properly.
Replacement of the reverse osmosis component: This reverse osmosis system contains a replaceable component critical to the efficiency of the system. Replacement of the reverse osmosis component should be with one of identical specifications, as defined by the manufacturer, to assure the same efficiency and contaminant performance.
9” dia.
14”
11-3/8”
3-1/2”
13”
FIG. 1
3
Page 4
Inspect Shipment
Your Reverse Osmosis Drinking Water System is shipped complete in one carton. Remove all items from your shipping carton.
Check all items against the packing list below. Note any items lost or damaged in shipment.
Reverse Osmosis
Assembly with Red &
Yellow Tubes attached
Green Supply Tube
Product Water
Storage Tank
Reverse Os-
mosis Faucet
with Black & Blue
Tubes attached
Note any damage to the shipping carton. Refer to the exploded view and parts list in the back of the manual for the part names and numbers of missing or dam­aged items. If problems exist, refer to the website or the toll free number listed throughout this manual.
Keep the small parts in the parts bag until you are ready to install them.
Packing List
Hanger
Brackets
Drain Adapter Kit
Eye
Dropper
Tee, Feed
Adapter
Parts Bag
Tube Bends
Nitrate / Nitrite
Connector
Test Kit
Tank
Thread
Sealing Tape
Coin
Battery
FIG. 2
Tools Needed
Review the tools needed list. See Fig. 3. Gather need­ed tools before proceeding with the installation. Read
TOOLS NEEDED
Tape
Measure
Adjustable
Wrench
Philips
Screwdriver
Flathead
Screwdriver
and follow the instructions provided with any tools list­ed here.
OR
Pipe Wrench
FIG. 3
Drill & Drill Bits,
if required
Adjustable Large Jaw
Pliers
4
Page 5
Plan Your Installation
Read through the entire manual before beginning your installation. Follow all steps exactly. Reading
this manual will also help you get all the benefits from your system.
Your Reverse Osmosis Drinking Water System can be installed under a sink or in a remote location. Typical remote sites are a laundry room or utility room. Review the location options below and deter­mine where you are going to install your system.
UNDER THE SINK LOCATION
The Reverse Osmosis Filter Assembly and storage tank may be installed in a kitchen or bathroom sink cabinet. See Fig. 4.
A suitable drain point is needed for drain water from the Reverse Osmosis system.
REMOTE INTERIOR LOCATION
The Reverse Osmosis Filter Assembly and storage tank may also be installed in a remote interior location away from the Reverse Osmosis Faucet. You will need a nearby water source and drain point. See Fig. 5.
CHECK SPACE REQUIREMENTS
Check size and position of items for proper installation into location chosen.
NOTE: For best system performance, the feed water to the system should be softened or have hardness less than 10 grains per gallon, with no iron.
Drain Adapter for Reverse Osmosis Waste Water
Cold Water
Supply
HOT COLD
Storage
Tank
Shutoff Valve
Sink Drain P-Trap
Typical Under Sink Installation
All install parts included in package.
Reverse
Osmosis
Assembly
FIG. 4
Outside Faucet
(Hard Water)
Soft, Cold Water
Soft, Hot
Water
Water
Heater
Typical Remote Installation
Additional parts required.
Hard Water Line
Shutoff
Valve
Water
Softener
Outside Faucet
(Hard Water)
Soft water to Reverse Osmosis System
Hard
Water
to
House
Air Gap
Floor Drain
(see p. 9)
Water Meter
To Faucet
Reverse Osmosis System
Reverse Osmosis Drain
Storage Tank
Main Shutoff Valve
FIG. 5
5
Page 6
Overview and Site Preparation
OVERVIEW
Read through the entire manual before beginning your installation.
There are seven steps to installing your Drinking Water system. They are as follows:
STEP A - Install Cold Water Supply Fitting
STEP B - Install Drain Adapter
STEP C - Install Reverse Osmosis Assembly
STEP D - Install Storage Tank
STEP E - Install Reverse Osmosis Faucet
STEP F - Connect Tubing
STEP G - Sanitize, Pressure Test & Purge System
These steps are explained in detail over the next few pages. Follow all steps. Reading this manual will also help you receive and use all the benefits your Reverse Osmosis system can give you.
PREPARE SITE FOR INSTALLATION
1. Before starting, close the hot and cold water shutoff
valves (See Figure 6).
2. Temporarily place tank and filter assembly into planned location. Check position of items and space required for proper installation. Ensure tubes may be routed without kinking.
3. Remove tank and filter from planned location and set aside.
NOTE: You must check and comply with all local plumbing codes.
NOTE: For best system performance, the feed water to the system should be softened or have hardness less than 10 grains per gallon, with no iron.
6
Page 7
Step A - Install Supply Water Fitting
CHOOSE TYPE OF WATER FITTING TO INSTALL
Check and comply with local plumbing codes as you plan, then install a cold feed (supply) water fitting. Refer to the Specifications page for supply water requirements. The fit­ting must provide a leak-tight connection to the RO 1/4" tub­ing. A typical connection using the included water supply fit­ting is shown in Figure 6.. An optional connection using standard plumbing fittings (not included) is shown in Figure 6B.
NOTE: Local code may dictate which type of water fit­ting is used. Consult a plumber if you are not familiar with local codes or plumbing procedures.
INSTALL COLD WATER SUPPLY FITTING
(Included with your package)
Hot Water
Shutoff Valve
cold water faucet stud
Cold Water
Shutoff Valve
water supply fitting (tee, feed adaptor)
This fitting will be installed on the cold water pipe. The fit­ting must provide a leak-tight connection to the Reverse Osmosis 1/4" tubing. Locate the cold water line in the sink cabinet. It is recommended, but not required, that the cold water line be soft water..
Complete the following steps to install the water supply fit­ting.
1. Close the water shut off valve that is immediately before supply fitting and open faucets to drain water from the sink cold water pipe.
2. Remove nut that connects the cold water faucet to cold water plumbing.
3. Thread water supply fitting onto pipe and reconnect nut to bottom of fitting.
OPTIONAL PIPE FITTINGS
(compression type shown)
NOTE: Be sure to turn off the water supply and open a
faucet to drain the pipe.
Complying with plumbing codes, install a fitting on the cold water pipe to adapt 1/4" OD tubing. A typical connection is shown in Figure 6B. If threaded fittings are used, be sure to use pipe joint compound or thread sealing tape on outside threads.
thread sealing
tape on threads
1/4” green tubing
cold water
pipe
to Reverse Osmosis inlet
Cold Water Supply Connection
(using included water supply fitting)
Hot Water
Shutoff Valve
Cold Water
Shutoff Valve
1/4” compression fitting
insert
FIG. 6
ferrule
1/4” green
cold water
pipe
tubing to Reverse
Osmosis inlet
Cold Water Supply Connection
(using compression fitting - not included)
FIG. 6B
7
Page 8
Step B - Install RO Drain Under Sink
INTRODUCTION
A suitable drain point is needed for the drain water from the Reverse Osmosis Filter. You have two options to choose from:
• Install the Drain Adapter included with your unit
See Fig 7, Fig. 8, and Fig. 9. This is used in under the sink installations. The drain adapter kit is installed onto your sink drain pipe above the P-trap. See Fig. 7.
• Use another existing drain in your home
(See Fig 10 & 11) This is usually used in remote location type installations. The drain tube from the Reverse Osmosis Filter runs directly to an open drain. See Fig. 10 & 11.
NOTE: An incorrectly connected drain point can cause water to leak from the faucet’s air gap.
NOTE: Local code may dictate which type of drain installation is used. Other than local code, either drain install type may be used in both under the sink or remote location installations. Consult a plumber if you are not familiar with plumbing pro­cedures.
INSTALL DRAIN ADAPTER KIT
(Under sink Installation)
A drain adapter kit is included in your package. Review the drain adapter kit parts in Fig. 8. Install the drain adapter above or ahead of the P-trap. See Fig. 7 & 9. Be sure to comply with your local plumbing codes. The drain adapter fits 1-1/2" sink drain pipes. Other drain pipe fittings, purchased locally, may be needed in addi­tion to the adapter.
1. Slowly disassemble the sink drain pipe between the sink P-trap and the sink tailpiece. See Fig. 7 & 9.
2. Clean the sink tailpiece to assure a leak-tight fit.
3. Install drain adapter directly onto the sink tailpiece
using the ferrule and nut. Snug the nut, but do not tighten. See Fig. 8.
4. Assemble the drain tubing connector to the drain adapter using the ferrule and nut. Snug the nut, but do not tighten. See Fig. 8.
NOTE: Locate so that the drain tubing from the Reverse Osmosis faucet will run straight to the adapter, with no dips, loops, or kinks. See Fig. 9.
5. Turn the connector to about 45° (10:00 or 2:00 position). See Fig. 8. Tighten the nut securely.
6. Assemble the P-trap to the drain adapter, and other
drain pipe fittings as required to complete the drain run. See Fig. 7.
NOTE: If needed, you can cut the unthreaded end of the adapter to make it fit. Do not cut too short or the adapter will not make a leak-tight seal with the connecting fitting.
7. Tighten all connections, but do not over tighten plas­tic connections.
Single trap Double Trap
Drain
Adapter
P–Trap
P–Trap
Under the Sink Installation
45°
Sink Tailpiece
Nut
Ferrule
Cut, if
needed
IMPORTANT: Locate drain adapter so that when the
Drain Tubing
HOT
black drain tube from the Reverse Osmosis Faucet is installed it will run straight to the adapter, with no dips, loops, or kinks.
Drain Adapter
Ferrule
Connector
COLD
10:00
Nut
Black Drain Tube
Drain Adapter
P–Trap
FIG. 7
45°
2:00
FIG. 8
FIG. 9
8
Page 9
Step B - Install RO Drain in Remote Location
Outside Faucet
Soft, Cold Water
(Hard Water)
Outside Faucet
(Hard Water)
Hard Water Line
BLUE Tubing to Reverse Osmosis Faucet
Soft, Hot
Water
Remote Installation
Location
Sump
1-1/2”
Air Gap
Water
Heater
1/4'' RED Tubing
1-1/2”
Air Gap
1-1/2”
Air Gap
Shutoff
Valve
Water
Softener
Hard
Water
to
House
RED
Tubing to
Drain
Soft water to Reverse Osmosis System
Water Meter
GREEN Tubing to Reverse Osmosis System
Reverse Osmosis System
Reverse Osmosis Drain - RED Tubing to Drain
YELLOW Tubing to Storage Tank
Storage Tank
Main Shutoff Valve
FIG. 10
Stand pipe
1-1/2”
Air Gap
Laundry
Tub
INSTALL A REMOTE DRAIN POINT AND AIR GAP (Remote Location)
Route the drain tubing to an existing drain in the house. A floor drain, laundry tub, standpipe, sump, etc. are suitable drain points. See Fig. 11. This type of drain is the preferred over the p-trap drain adapter.
Be sure to provide a 1-1/2” air gap between the end of the hose and the drain point. This will prevent water from backing up into the system.
NOTE: Check your local plumbing codes.
Floor Drain
9
FIG. 11
To install a remote drain point, complete the follow­ing steps:
1. Locate the 1/4” red tubing on the Reverse Osmosis
filter assembly. See Fig. 10.
2. Determine if this length is long enough to reach the drain point. Longer lengths of tubing (see parts list in back of manual) may be needed.
3. If longer tubing is required, disconnect the 1/4” red tubing and replace with an adequate length of tubing to reach the drain point. Refer to Step F later in the manual on how to disconnect and connect tubing.
NOTE: A flow control insert is located inside the elbow fitting that the drain tube connects to. Refer to Fig 28. Leave this fitting in place.
4. Route the tubing to the drain point and secure at the end with a bracket (not included). See Fig. 11. Provide a 1-1/2” air gap between the end of the tube and the drain. See Fig. 11.
Page 10
Step C - Install RO Filter Assembly
INSTALL REVERSE OSMOSIS FILTER ASSEMBLY
The Reverse Osmosis Filter Assembly is mounted on hanger washers.
See Fig 12. The hanger washers allow you to lift the filter assembly from the washers without any hardware removal. When planning your installation, you need to leave room for changing filters.
Complete the following steps to install your Reverse Osmosis Filter Assembly:
1. Remove the cover.
2. Locate mounting slots on back inside of the assem-
bly. See Fig 12.
3. Hold the assembly up to the wall surface and mark locations for the hanger washers. See Fig 12. Mount the unit high enough to allow room to change filters without taking the unit off of the wall.
4. Fasten the hanger washers to the wall using the screws provided.
5. Hang assembly on washers.
6. Replace cover.
Hanger
Washer (2)
9''
Screw (2)
15-1/2'' minimum up
from floor. This allows
space to remove and
change filters
FIG. 12
Step D - Install Storage Tank
INSTALL STORAGE TANK
1. Apply thread sealing tape (2 wraps clockwise) to
the threads on the nipple at the top of the tank. See Fig 13.
2. Locate the tubing connector. See Fig. 13. Slowly tighten the tubing connector onto the tank nipple 7-8 full turns, so as not to cross thread or overtighten.
3. Do not connect the tube at this time. This will occur later in the assembly.
4. Place the storage tank next to the Reverse Osmosis Assembly. The tank can be placed upright or on its side.
Tank
Nipple
Tubing Connector
Tubing Insert
Tubing Nut
Storage Tank
FIG. 13
10
Page 11
Step E - Install RO Faucet
SELECT LOCATION OF REVERSE OSMOSIS FAUCET MOUNTING HOLE
You will need to select the location of the Reverse Osmosis Faucet. You have three options to choose from:
• Use the existing sink top hole for the spray hose
or soap dispenser (Must be 1-3/8” in diameter)
• Drill a new hole in the sink
• Drill a new hole in the countertop next to the sink
1. Determine where you are going to install your
Reverse Osmosis Faucet.
2. Check to ensure the Reverse Osmosis faucet will mount flat against the mounting surface.
3. Visually review the routing of the tubes from the Reverse Osmosis filter assembly to the faucet. Check to ensure there is adequate tube routing space between the faucet and filter assembly.
4. If drilling is needed, drill a 1-3/8" diameter hole in the mounting surface.
IMPORTANT: Drilling holes into countertops and sinks should only be performed by an installer who is qualified for drilling such materials. Drilling of surfaces made of stone or solid sur­face materials such as granite, marble, Corian™ or other plastic resin products or sinks made of porcelain or stainless steel may cause perma­nent, irreparable damage to the sink or counter­top surface.
FIG. 14
11
Page 12
Step E - Install RO Faucet (cont.)
INSTALL REVERSE OSMOSIS FAUCET
1. Locate and organize your RO faucet install parts. Refer to
Fig. 15.
2. Mount faucet base to sink hole until the faucet base is flat against the sink surface. The rubber gasket should be between the sink surface and the faucet base.
3. Tighten the toggle bolts until the base is firmly mounted to the sink surface. Do not overtighten.
4. Locate the faucet body. (The black and blue tubes are already connected to the faucet.) Insert these tubes into the sink hole until approximately one foot of tube length and the faucet body are left above the counter surface. Do not kink the tubes in the process. See Fig. 14.
NOTE: If you routed the red drain tubing directly to a remote drain point (see page 9), disregard step 5 and move on to step 6.
5. Locate the 1/4" red tubing. One end is connected to the RO filter assembly. See Fig 23. A. Route the loose end of the red tube through countertop
to faucet.
B. Cut the loose end of the red tube square and to length.
See Fig. 18 for tube cutting instructions.
NOTE: Tubing lengths should allow for the removal of the assembly from the hanger washers for servicing. If tubing lengths are shortened for neater appearance, it may be necessary to keep the assembly on the hanger washers for service.
C. Insert all the way onto the 1/4" faucet barb fitting on
faucet. See Figs. 16, 19 & 20.
D. Pull on the tubing to be sure it is held firmly in the fit-
ting.
6. Mount the faucet body onto the faucet base, 1/4 turn.
FAUCET ELECTRONICS
Inside the faucet base is a battery operated 6 month timer. An amber LED indicator is also located in the front of the faucet base. This LED will flash continuously after 6 months has passed. This indicates that it is time to replace the battery, prefilter and postfilter.
INSTALL BATTERY
To install battery, complete the following steps.
1. Remove the screw on the right side of the faucet base.
2. Press the battery housing upward from the front faucet
base until it releases from the faucet base. See Fig. 15.
3. Install the battery (CR 2032 or equivalent). Place battery into the holder with the positive (+) side facing the back of the holder.
4. When the battery is installed the LED will flash six times and turn off. This indicates the battery is fully charged. After the six flashes, the timer enters the 6 month time cycle.
NOTE: If the LED repeatedly flashes two times, the battery needs to be replaced.
5. Re-install the battery housing and firmly tighten the mount­ing screw. See Fig. 15.
Timer
Housing
Amber LED
Screw holding
the battery
housing in place
Battery
Housing
Battery,
negative (–)
side facing
the front
Faucet
Base
BLUE TUBE
3/8” quick connect fitting for the blue tube
Faucet Body
Faucet Base
Rubber Gasket
Toggle Bolts
Screw
FIG. 15
BLACK TUBE
3/8” barb fitting for the black tube
RED TUBE
1/4” barb fitting for the red tube
FIG. 16
12
Page 13
Step F - Connect Tubes
HOW TO CUT AND CONNECT THE TUBES
Your Reverse Osmosis system includes push-in fittings for quick tubing connection. Review the following instructions before connecting the tubes in the next step. Failure to follow these instructions may lead to future leaks.
Cut tubes to length
1. Use a sharp cutter or knife to cut the end of tubing.
Always cut the tubing square. See Fig. 18.
2. Inspect the tube up to 1” from the end to be sure there are no nicks, scratches or other rough spots. If needed, cut the tubing again. See Fig. 18.
NOTE: Tubing lengths should allow for the removal of the assembly from the hanger wash­ers for servicing. If tubing lengths are shortened for neater appearance, it may be necessary to keep the assembly on the hanger washers for service.
Connect tubes
NOTE: Remove foam plugs before connecting tubes (See Fig. 17). Discard foam plugs.
1. Push tubing through collet, until it engages the o­ring. See Fig. 19. Continue pushing until the tube bottoms out against the back of the fitting. See Fig.
20. Do not stop pushing when the tube engages the o-ring. Failure to follow these instructions may lead to future leaks. When a 1/4” tube is fully engaged, 11/16” of the tube has entered the fitting. When a 3/8” tube is fully engaged, 3/4” of the tube has entered the fitting. Mark tube with a piece of tape or marker. See Figs. 19 & 20.
2. If additional tubing is required, see parts list at the end of this manual.
Push-in Fitting
Foam Plug
Remove and Discard Foam Plugs
Push-in Fitting
Tube
Cut tubing square with end of tubing round,
smooth, with no cuts, nicks or flat spots.
Tube Corrrectly Cut
Collet O-Ring
Tube Partially Engaged with Fitting
Collet O-Ring
FIG. 17
FIG. 18
FIG. 19
To Disconnect Tubes
1. Push the collet inward with a finger tip. See Fig.22.
2. Continue holding collet inward while pulling the tub-
ing out. See Fig. 22.
Collet
Fitting
O-Ring Seal
Collet and O-Ring
FIG. 21
13
Tube Fully Engaged with Fitting
Collet (depress to
remove tubing)
Tubing
Disconnect Tubing
FIG. 20
FIG. 22
Page 14
Tee, Feed
Adapter
Step F - Connect Tubes (cont.)
NOTE: Tubing lengths should allow for the removal of the assembly from the hanger washers for servicing. If tubing lengths are shortened for neater appearance, it may be necessary to keep the assembly on the hanger washers for service.
3/8” YELLOW
HOT COLD
1/4” GREEN
Sink
P–Trap
Drain Adapter
3/8” BLACK Tubing
3/8” BLUE
1/4” RED
NOTE: Tube colors match collet colors.
If tubing needs to make
a sharp bend, use
included tube benders
to prevent kinking.
Tube Connections
ROUTE YELLOW TUBE TO STORAGE TANK
1. Locate the yellow tube attached to the Reverse Osmosis
filter assembly.
2. Route the loose end of the yellow tube to the fitting on top
of the storage tank. See Fig. 23.
3. Cut tube square and to length. See Fig. 18.
4. Do not connect at this time. This will occur in the sanitizing
step.
CONNECT GREEN TUBE TO COLD WATER SUPPLY PIPE
1. Route one end of the 1/4” green tube to the fitting on the
water supply pipe. See Fig. 23.
2. Cut tube square and to length. See Fig. 18.
3. Connect to cold water supply fitting. See Fig. 6.
4. Route the other end of the green tube to green collet to the
fitting on the left side of the Reverse Osmosis filter assembly.
5. Cut tube square and to length. See Fig. 18.
6. Insert all the way into the fitting. See Figs. 19 & 20.
7. Pull on the tube to be sure it is held firmly in the fitting.
Tubing Connector
Tube Bender
FIG. 23
CONNECT BLUE TUBE TO REVERSE OSMOSIS ASSEMBLY
1. Locate the blue tube attached to the faucet.
2. Route the loose end of the 3/8" blue tube to the blue collet
on the right side of the Reverse Osmosis filter assembly.
3. Cut tube square and to length. See Fig. 18.
4. Insert all the way into the fitting. See Figs. 19 & 20.
5. Pull on the tube to be sure it's held firmly in the fitting.
CONNECT BLACK TUBE FROM REVERSE OSMOSIS FAUCET TO DRAIN ADAPTER
1. Locate the 3/8" black tube attached to the faucet. Fig 23.
2. The loose end needs to be attached to the black collet on
the sink drain adapter.
3. Cut this tube as needed to route it as straight as possible, without loops, dips, or kinks.
4. Cut the end of the tube square. See Fig. 18.
5. Insert all the way into the fitting. See Figs. 19 & 20.
6. Pull on the tube to be sure it is held firmly in the fitting.
RED TUBE TO REVERSE OSMOSIS FAUCET
The red tube connection was completed in the faucet assembly steps.
14
Page 15
Step G - Sanitize, Test and Purge System
SANITIZE THE SYSTEM
Sanitizing is recommended immediately after installa­tion of the Reverse Osmosis system. It’s also recom­mended after servicing inner parts. It is important that the person installing or servicing the system have clean hands while handling inner parts of the system.
Complete the following steps to sanitize the system. See Fig. 24.
1. Make sure that the water supply to the Reverse Osmosis system is off.
2. Open the Reverse Osmosis faucet. If the tank is not already empty, allow the water to empty.
3. Locate the eyedropper included in parts bag and common household bleach (5.25%).
4. Add 3 ml. of bleach into open end of yellow tubing. Handle bleach according to bleach manufacturer’s recommendations. See Fig. 24.
5. Connect yellow tubing to tank connector. See Figs. 13 and 24.
6. Sanitizing the system will be completed during the pressure test and purging steps on the following page.
NOTE: The bleach must be removed from the sys­tem before drinking the water. See purging instruc­tions on the next page.
FIG. 24
15
Page 16
Step G - Sanitize, Test and Purge System (cont.)
PRESSURE TEST THE SYSTEM
NOTE: Complete the sanitizing procedures on the preceding page before pressure testing.
To pressure test the system, complete the following steps.
1. Open the water supply valve to the Reverse Osmosis system.
2. Purge air from the house plumbing by opening sev­eral house faucets. Close faucets when water runs smooth, with no spurting.
3. Pressure will start to build in the RO system. In about 2 hours check all fittings and connections. Check for water leaks. Fix leaks if any are found. If problems exist, refer to the troubleshooting chart or call the toll free number below).
NOTE: When the system is first pressurized, water may ''spurt'' from the faucet air gap hole until air is expelled from the RO system.
Please review the following operating features before using your Reverse Osmosis system:
You will not have filtered water immediately. It may take several hours to fill the storage tank and create maximum flow from the Reverse Osmosis faucet.
Reverse
Osmosis
Kitchen
Faucet
HOT COLD
Storage
Tank
Water Supply Shutoff
Valve to Reverse
Osmosis System
Faucet
Tee, Feed Adapter
FIG. 25
Water Pressure from the Reverse Osmosis faucet will be less than your standard faucet.
Water will run to the drain while the Reverse Osmosis system is producing water, even if you are not drawing water from the Reverse Osmosis faucet. You may hear a small quantity of water going to the drain at times when water is not being used. This is normal. Water going to the drain will automatically shut off when the storage tank is full.
PURGING THE SYSTEM
To purge the system, complete the following steps:
1. Open the Reverse Osmosis faucet and let water flow through the system for 24 hours. Water flow from the faucet will be a slow trickle at this time.
NOTE: Do not consume water from the RO sys­tem until purging is complete.
2. Close the RO faucet after the 24 hour period is complete, and allow the storage tank to fill. This may take several hours.
3. When the storage tank is full (you will no longer hear water trickling into the drain), open the RO faucet and allow the storage tank to empty.
4. When the storage tank is empty (the water flow from the RO faucet will slow to a trickle), close the RO faucet and allow the storage tank to fill again.
5. Purging is complete, and your Reverse Osmosis system is ready for use.
NOTE: As with all other water system applications, leaks may occur. Because the system pressure builds slowly, leaks may not be immediately appar­ent. Recheck for leaks 24 hours after purging the system is complete.
16
Page 17
How Your RO Water System Works
HOW YOUR REVERSE OSMOSIS SYSTEM WORKS
Introduction: Your Reverse Osmosis (RO) Drinking
Water System uses your household water pressure to force water through three filters. Minerals and impuri­ties are filtered out. Delicious tasting drinking water goes to the storage tank-ready for your use. Minerals and impurities are sent down the drain. The following paragraphs will explain in detail how your Reverse Osmosis Drinking Water System works.
Prefilter: Water from the cold supply pipe enters the prefilter. See Fig. 26. The prefilter is a replaceable sediment cartridge with activated carbon in its compo­sition. The cartridge reduces taste, odor, sand, silt, dirt, other sediments, and up to the amount of chlorine shown in the specifications.
Reverse Osmosis Cartridge: Filtered water flows from the prefilter to the Reverse Osmosis membrane cartridge. See Fig. 26. The Reverse Osmosis cartridge is a tightly wound special membrane. The membrane reduces the dissolved solids and organic matter. High quality product water (about one ounce per minute) exits the Reverse Osmosis cartridge. The product water flows to the storage tank, postfilter or Reverse Osmosis faucet. Drain water, with the dissolved solids and organic matter, is routed to the drain.
Storage Tank: The storage tank holds product water. See Fig. 26. A diaphragm inside the tank holds water pressurized to about half of supply water pressure when the tank is full. This provides fast flow to the Reverse Osmosis faucet. When the tank is empty of water, the pressure at the air valve is 5 - 7 psi.
Reverse Osmosis Faucet: The sink or countertop faucet has a hand operated knob to dispense drinking water. See Fig. 26. An air-gap is built into the faucet drain water connection to comply with plumbing codes.
Faucet Electronics: Inside the faucet base is a bat­tery operated 6 month timer. See Fig. 15.
An amber LED indicator is located in the front of the faucet base. This LED will flash continuously after 6 months have passed. This indicates that it is time to replace the battery, prefilter and postfilter.
Shutoff Assembly: The unit has an automatic shutoff system to conserve water. When the storage tank has filled to capacity, and the drinking water faucet is closed, pressure closes the shutoff to stop flow to the drain. After enough drinking water is used, pressure in the system drops, and the shutoff opens to allow the tank to be refilled. See Fig. 26.
Check Valve: A check valve is located in the Reverse Osmosis manifold above the center cartridge. The check valve prevents a backward flow of product water from the storage tank to drain. A backward flow could damage the Reverse Osmosis Membrane. See Fig. 26.
Flow Control: Water flow to the drain is restricted by the flow control. It maintains the desired flow rate to obtain the highest quality drinking water. The flow con­trol is located inside the elbow fitting on the Reverse Osmosis manifold drain port. See Fig. 26.
Postfilter: Water goes through the postfilter before going to the Reverse Osmosis faucet. See Fig. 26. The postfilter is an activated carbon type filter. Any remaining tastes and odors are reduced from the product water. Clean, high quality drinking water is available at the faucet.
If you have any questions about system operation or maintenance,
call toll free:
1-800-689-4571 Monday - Friday, 8:30 am - 6:00 pm EST, or Saturday 9:00 am - 3:00 pm EST,
or visit us online at: www.truebluewatersolutions.com
17
Page 18
How Your RO Water System Works
PRODUCT WATER FAUCET
Air Gap
6
PRODUCT WATER
BLACK
Gravity
DRAIN WATER
Drain
WATER
IN
AUTOMATIC
SHUTOFF
GREEN
Drain Flow
Control
Check Valve
8
BLUE
1
PRODUCT
WATER
STORAGE
4
RED
PREFILTER
5
RO
MEMBRANE
POSTFITLER
3
7
YELLOW
2
Reverse Osmosis Water Flow Schematic
FIG. 26
Water Flow Description
1. Water enters prefilter. Sand, silt and other sediments are reduced. Chlorine is also reduced. See Fig. 26.
2. Water leaves prefilter and proceeds to the Reverse Osmosis Cartridge.
3. Water enters the Reverse Osmosis membrane. Dissolved solids are reduced.
4. Processed water leaves the Reverse Osmosis Membrane and flows to the storage tank.
5. Drain water with dissolved solids leaves the Reverse Osmosis membrane and flows to the drain.
6. Faucet is activated.
7. Processed water leaves the storage tank and flows to the postfilter, where it is filtered to ensure fresh taste.
8. Water flows to the Reverse Osmosis faucet.
18
Page 19
Maintenance
PREFILTER / POSTFILTER MAINTENANCE
NOTE: It is recommended to replace the battery, prefilter and postfilter cartridges at least every 6 months of product water use. Replace more often if they begin to plug with sediment.
The prefilter and postfilter are replaceable sediment cartridges with activated carbon in their composition. See Fig. 27. You must periodically replace the prefilter and postfilter cartridge. This will protect the RO mem­brane from being destroyed by chlorine. It will also pre­vent the filters from plugging with sediment.
You may notice a slower output of product water as the prefilter and postfilter build up with sediment. Replace the prefilter and postfilter cartridges when this occurs. You should replace the battery whenever you replace the cartridges.
RO MEMBRANE CARTRIDGE MAINTENANCE
The Reverse Osmosis cartridge is a tightly wound spe­cial membrane. See Fig. 27. The membrane reduces the dissolved solids and organic matter. The life of the Reverse Osmosis membrane cartridge depends mostly on the pH and hardness of the supply water (see Specifications). Cartridge life is shorter with higher pH. For example, if supply water pH is from 6.8 to 7.7, the cartridge may last for well over one year. However, cartridge life may be as short as 6 months if the pH is as high as 8.5 to 10. Higher pH weakens the cartridge membrane and causes pin-hole leaks. It's time to replace the Reverse Osmosis cartridge when the pro­duction rate and/or quality of product water drops. Product water may begin to taste different, indicating solids and organics are passing through the Reverse Osmosis membrane. See Reverse Osmosis cartridge replacement.
REVERSE OSMOSIS CARTRIDGE REPLACE­MENT
Complete the following steps to replace the cartridges.
NOTE: Do not remove manifold from mounts. Flexing or twisting may damage the manifold.
1. Remove (turn to the left) the prefilter cartridge from the manifold to stop flow to the Reverse Osmosis cartridge.
2. Remove the Reverse Osmosis cartridge.
3. Remove the postfilter cartridge.
4. Discard the cartridges in a proper manner.
5. Install new cartridges in reverse order (post filter,
Reverse Osmosis and then prefilter). Turn cartridges to the right to reattach to the filter heads. Do not overtighten.
Cover
Manifold
Prefilter
Cartridge
RO
Cartridge
Turn to the left
to remove
6. Remove and replace the timer battery. See page 12.
7. Purge the Reverse Osmosis system. See page 16
for instructions.
Postfilter Cartridge
FIG. 27
PREFILTER / POSTFILTER CARTRIDGE REPLACEMENT
Complete the following steps to replace the cartridges.
NOTE: Do not remove manifold from mounts. Flexing or twisting may damage the manifold.
1. Remove the prefilter cartridge (turn to the left) from the filter head. Then remove the postfilter cartridge.
2. Discard the cartridges in a proper manner.
3. Install new cartridges in reverse order (postfilter first,
then prefilter). Turn cartridges to the right to re­attach to the filter heads. Do not overtighten.
4. Remove and replace the timer battery. See page 12.
5. Purge the Reverse Osmosis system. See page 16
for instructions.
19
Page 20
Maintenance
FLOW CONTROL
The flow control is required for proper operation of the Reverse Osmosis system. See Fig. 28. The flow control, located inside the push-in elbow fitting on the drain port of the system housing, keeps water flowing through the mem­brane at the required rate. This ensures that the system pro­duces the best quality product water.
Periodically check the flow control to be sure the small hole through it is clean and unrestricted.
If the flow control requires service, review the exploded view in Fig. 28. Assemble and disassemble as shown. If the flow control remains in the manifold when the push-in elbow fit­ting is removed, you will need to remove the drain port’s col­let and o-ring, as shown in the next section, to retrieve it.
CHANGE COLLET AND O-RING
1. Remove the collet and o-ring from the fitting with a small
screwdriver. Do not scratch the internal walls of the collet port. See Figs. 29 & 30.
2. Clean collet port, lubricate with silicone-based lubricant, and insert the o-ring seal into the bottom of the port. See Figs. 29 & 30.
3. Push the collet inward until it locks in place. See Figs. 29 & 30.
Flow Control
Insert
Push-in
Elbow Fitting
1/4” Red
Tubing
To
Drain
Push o-ring seal into
bottom of port then
follow with collet.
Collet
Change Collet and O-Ring
FIG. 28
Fitting
O-Ring Seal
FIG. 29
CHANGE BATTERY
To change battery, complete the following steps.
1. Remove the screw on the right side of the faucet base. See Fig. 31.
2. Press the battery housing upwards from the front faucet base until it releases from the faucet base. See Fig. 31.
3. Replace the battery (CR 2032 or equivalent). Place bat­tery into the holder with the positive (+) side facing the back of the holder.
4. When the battery is installed the LED will flash six times and turn off. This indicates the battery is fully charged. After the six flashes, the timer enters the 6 month time cycle. If it repeatedly flashes two times, it is not a fully charged battery.
5. Re-install the battery housing and firmly tighten the mount­ing screw. See Fig. 31.
Collet (depress to
remove tubing)
Tubing
Disconnect Tubing
Battery
Housing
Battery,
negative (–)
side facing
the front
Faucet
Base
FIG. 30
Screw
FIG. 31
20
Page 21
Troubleshooting
Problem: Chlorine taste and/or odor in the RO product water.
Cause: The level of chlorine in your water supply
Cause: The prefilter is no longer reducing chlorine
exceeds maximum limits, and has destroyed the Reverse Osmosis membrane.
from the water supply.
Problem: Other taste and/or odor.
Cause:
Cause:
Cause: Contamination in product water storage tank. Correction: Use sanitizing procedures. Replace prefilter and postfilter car-
Cause: System contamination. Correction: Sanitize entire system. Call 1-800-689-4571 for instructions.
Postfilter expended.
Reverse Osmosis membrane cartridge expended.
Problem: System makes product water too slowly.
Cause: Water supply to the Reverse Osmosis sys-
Cause: Prefilter or Reverse Osmosis membrane
tem not within specifications.
cartridges plugged with sediment.
Problem: System makes lower amount of product water than usual.
Cause: Storage tank air-charge less than 5-7 psi. Correction: Open Reverse Osmosis faucet and drain tank until flow slows to
Problem: High total dissolved solids (TDS) in product water.
Cause: Water supply to the Reverse Osmosis sys-
Cause: Plugged drain flow control insert. Correction: Replace drain flow control insert. See page 20.
tem not within specifications.
Problem: Continual water flow to drain and low or no water production.
Cause: Missing flow control insert in drain port. Correction: Make sure flow control insert is in place. See page 20.
Problem: Water leaking from faucet airgap hole.
Cause: Drain side of faucet airgap (3/8” black tub-
ing) plugged, restricted or incorrectly con­nected to drain point.
Problem: Faucet LED indicator light does not function after battery change.
Cause: Battery dead. Correction: Replace with new battery. See page 20.
Cause: Battery installed incorrectly. Correction: Install battery correctly. See page 12 or 20.
Problem: Water leaks at push connect fittings.
Cause: Tubing not cut square. Correction: Cut tubing square. See pages 13 & 14.
Cause: Tubing not pushed in all the way. Correction: Push tubing in all the way. See pages 13 & 14.
Cause: Tubing nicked. Correction: Remove tube from connection. Remove nicked portion by cut-
Cause: Outer tubing surface finish not smooth. Correction: Remove tube from connection. Remove problem area by cutting
Correction: If the water supply contains more than 2.0 ppm of chlorine,
additional filtering of the water supply to the Reverse Osmosis is needed. Contact your local water supplier. Correct this condi­tion before doing maintenance on the Reverse Osmosis system.
Correction: Replace the prefilter, postfilter and Reverse Osmosis membrane
cartridges. See page 19.
Correction: Replace the postfilter cartridge. If taste and odor persist, replace
the prefilter cartridge and Reverse Osmosis membrane car­tridge. See page 19.
tridges. See page 15.
Correction: Increase water pressure, precondition the water, etc., as need-
ed to conform before doing maintenance on the Reverse Osmosis system.
Correction: Replace the prefilter cartridge. If rate does not increase, replace
the postfilter cartridge and Reverse Osmosis membrane car­tridge. See page 19.
a drip. Keep faucet open and check tank pressure. If low, pres­surize to 6 psi. Close faucet to refill the tank.
Correction: Increase water pressure, precondition the water, etc., as need-
ed to conform before doing maintenance on the Reverse Osmosis system.
Correction: Send treated and untreated water samples to a water analysis
lab for testing. It is important to test both the treated and untreated water to determine system performance. If the TDS is not within the system’s performance guidelines, replace the pre­filter, post filter and RO membrane cartridges.
Correction: Inspect and eliminate restriction or plug. Check that drain line is
routed properly. Refer to installation instructions for proper drain connection. See pages 5 & 9.
ting tube to shorter length. Reinsert in connection. See pages 13 & 14. If removing the drain line, leave in place the elbow fitting that it connects to. See page 20.
tube to shorter length. Reinsert in connection. See pages 13 &
14. If removing the drain line, leave in place the elbow fitting that it connects to. See page 20.
Need help troubleshooting?
Call Toll Free 1-800-689-4571, Monday - Friday, 8:30 am - 6:00 pm EST, or Saturday 9:00 am - 3:00 pm EST.
21
Page 22
Exploded View
21
20
11
22
10
5
Manifold Housing
6
7
4
8
9
3
PUSH-IN FITTINGS
O-Ring Seal
Collet
2
1
23
17
16
15
14
1/4” red
tubing
13
18
12
19
22
Page 23
Parts List
Key
No.
1 9006062 Screw (2 req’d)
2 9041700 Hanger Washer (2 req’d)
3 7115432 O-ring (2 req’d)
4 7272658 Check Valve
5 7273337 Screw (6 req’d)
6 7281330 Washer (4 req’d)
7 7273345 Automatic Shut-off Cover
8 7250876 Diaphragm Kit
9 7234325 Plunger & Spacer Ring Kit
10 7275185 Flow Control Insert
11 7253785
12 1081-01-FA-Z2 Pre & Post Filter Cartridge
13 1081-01-FB-Z1 RO Membrane Cartridge
14 7205326 Storage Tank
15 9003203 Nut, 3/8” Tubing
16 7131349 Insert, 3/8” Tubing
Part No. Description
Elbow, Plug-in, 1/4 Stem x 1/4 Tube
Key
No.
Part No. Description
17 7201681 Connector, 1/4 NPT x 3/8 Jaco
18 7208489 Drain Adapter
19 7227310 Tee, Feed Adapter
20 7292682 Faucet, with base and electronics
21 7272763 Cover
22 7281005
23 7281013
7315189
¢
7161823
¢
7161784
¢
7157280
¢
7161750
¢
7314183 Coin Battery
¢
7273557 Tube Bend - 5/16”
¢
7273565 Tube Bend - 3/8”
¢
7279749 Dropper
¢
Push-in Fitting Kit, 1/4” u =
Push-in Fitting Kit, 3/8” u =
Auxiliary Storage Tank =
Tubing, 1/4” x 20’ - white p =
Tubing, 1/4” x 100’ - white p =
Tubing, 3/8” x 20’ - white p =
Tubing, 3/8” x 100’ - white p =
u These o-rings and collets are for replacement in the manifold housing only.
They do not fit the other push-in fitting on Key No. 17.
= Not included.
p Tubing lengths for remote installations, direct replacement for colored lengths of tubing.
¢ Not illustrated.
To order replacement parts, call toll free 1-800-689-4571, Monday - Friday, 8:30 am - 6:00 pm EST, or Saturday 9:00 am - 3:00 pm EST.
Manufactured for Defender Security Company by
Ecodyne Water Systems
1890 Woodlane Drive Woodbury, MN 55125
23