Eclipse 902-385 Operating Instructions Manual

Area of application: This tool is only designed for the use described in the operating instructions. Any other use may result in accidents or damage of the tool.
1. Standard pliers functions: (combination, tube, flat pliers / open end wrench Set function lever in position „open“. Set adjustment screw for jaw opening size according to application.
2. Grip pliers functions: (tube, flat pliers) Set function lever in position „lock“. Set adjustment screw for jaw opening size according to application.
3. Crimp functions: (coax connectors RG 58,59,62, insulated terminals AWG 22-10 (0,5-6,0mm²), wire ferrules AWG 22-10 (0,5-6,0mm²). Set function lever in position „lock“. Turn adjustment screw for jaw opening size clockwise until stop, then turn 1/4 turn counter-clockwise. Insert crimp dies.
4. Riveting function: (riveting attachment) Set function lever in position „open“. Set adjustment screw for jaw opening size that the 2 arrows will match. Assemble riveting attachment und guide according to rivet size. If handforces are too high during riveting operation, turn adjustment screw 1/4-1 turn counter-clockwise.
Raptor RCG
902-385
Operating Instructions
Eclipse Tools
13302 Chula Rd Amelia, VA 23002
Tel: 804-561-2610 Fax: 804-561-2642
e-mail: custsvc@eclipsetools.com Internet: www.eclipsetools.com
1. standard pliers functions 2. grip pliers functions
- 1/4
= Ø =
3. crimp functions 4. riveting function
Loading...