All numbers subject to variation due to production tolerances. ECLER S.A. reserves the right to make changes or
improvements in manufacturing or design which may affect specifications.
3
1. IMPORTANT NOTE
We appreciate your confidence in choosing our remote control panel WPmSCREEN. In order to
obtain the best performance and efficiency it's VERY IMPORTANT to carefully read and follow all
considerations specified in this manual before connecting the product.
In order to guarantee the optimum operation of this unit, we strongly recommend that its
maintenance be carried out by our Authorised Technical Services.
1.1. Safety Precautions
Do not expose the unit to rain or water splashes, and do not place liquid containers or
incandescent objects like candles on top of the unit.
Should any connection / disconnection task be done, always disconnect the unit from the mains
supply.
There are no user serviceable parts inside the unit.
The front panel should not be cleaned with dissolvent or abrasive substances because silkprinting could be damaged. To clean it, use a soft cloth slightly wet with water and neutral liquid soap;
dry it with a clean cloth. Be careful that water never gets into the unit through the holes of the front panel.
2. INTRODUCTION
The WPmSCREEN is a device of the EclerNet family that can be programmed to control one or
more networked EclerNet devices; you can even control a installation combining a multitude of different
EclerNet devices: MIMO88 digital matrices, NXA-series digital audio managers, NZA-series multi-channel
amplifiers, NPA-series stereo amplifiers, etc.
The WPmSCREEN is suitable for wall mount installation (surface-mounted, flush-mounted or on a
standard VESA 75 bracket).
It features a 7" touch screen displaying the graphic User Control Panels (UCPs) that have been
programmed in the EclerNet Manager application software; this screen is the interface between the user
and the associated network of EclerNet devices
.
3. INSTALLATION AND CONNECTIONS
The WPmSCREEN is suitable for surface and flush wall mount applications (using optional SIMON
510201103-039 flush-mount box or equivalent) and fits on a VESA 75 standard bracket. The packaging
includes 4 screws for installation on a VESA 75 bracket and 6 screws for installation in a flush-mount box
(SIMON 510201103-039 or equivalent, not supplied).
If the installation is directly performed on a work surface, wood, etc., 4 bolts with a maximum
diameter of 4 mm (5/32") should be used (not supplied).
The WPmSCREEN has 2 connectors:
DC Power: round jack for connection to the universal power supply provided with the product
Ethernet Port: RJ45 jack of the unit's network interface. It can be directly connected (point to point)
to a single EclerNet device, for its direct and exclusive control, or to an Ethernet port of the network
the rest of the EclerNet devices of the installation are connected to. The connecting cable can be a
standard or crossover CAT5 cable
4
4. OPERATION
From EclerNet Manager application, you can create remote control panels for the system (UCPs) to
manage one or more MIMO88, NXA, NZA or NPA units in a networked installation. Each panel can consist
of one or more pages that include graphics, text, volume controls, buttons, VU meters, LED indicators, and
so on. In this way each remote user may have his own control panel(s) custom tailored to his needs and
privileges, and in one system, a very simple control panel for some users can coexist with others, more
complex and having higher levels of authorization.
Once the UCPs are created, the network needs a web server for the potential web clients that will
control the installation thanks to the UCPs retrieved from the web server, locally visualized and managed.
The web server can be one of these two types of devices:
A Windows® PC running the created EclerNet Manager project in "Deploy" mode
A WPmSCREEN running the EclerNet project previously created with the EclerNet Manager
application
Note:
It is important to note that only one of these two devices running the EclerNet Manager
application and the same project can exist in a same network, and never more than one at a time
whatever the type, since all would simultaneously try to take control of the hardware devices (MIMO88,
NXA, etc.) included in the project
As for the web clients, they can be of the following types:
The main WPmSCREEN itself (if existing) that acts as a web server can be its own web client
Additional WPmSCREEN units, enabled as web clients
The PC (if existing) that acts as a web server can be its own web client
Computers, tablets and the like, running an Internet browser (Internet Explorer, Google Chrome,
Mozilla Firefox, etc.)
Devices with Android operating system (tablets, smartphones)
Devices with Apple iOS (iPad, iPhone, etc.)
Any of them can recover and operate UCPs pointing to the web server's IP address.
Different web clients can simultaneously load different UCPs and operate the project at the same
time, each one controlling a part of the system.
Note: please consult the user manual (chapters 10 and 11) of your EclerNet Manager application
for more information about programming UCP panels and the WPmSCREEN
Note: the EclerNet Manager application is available on www.ecler.com
,
5
5. LOCAL CONFIGURATION OF THE UNIT
The WpmSCREEN has setting and configuration menus for a local access from the touch screen
of the device. The same settings are remotely accessible when the screen is under the control of a
remote computer running the EclerNet Manager application.
Local access to the configuration menus can be done by clicking on the SETUP icon:
The available configuration menus are the following:
6
5.1. “Connect to…” Menu
This menu allows you to set the UCP server the unit will connect to as a client. The UCP server
may be a computer, another WPmSCREEN or even the same WPmSCREEN. In any case, the UCP
server shall host an EclerNet Manager project that includes a series of UCPs which can be remotely
managed by any UCP client.
It is possible to directly enter the IP address of the server device, using the touch keyboard
displayed on the screen, or to select a device from a list of automatically detected devices, which is
accessed by clicking on the button with the list icon to the right of the "Connect" button:
7
Note: in the list of detected devices, the name of the WPmSCREEN used to access the "Connect
to" menu will appear in green:
After selecting an IP address using either of these methods, you must press the "Connect" button
to confirm the selection and start the process of connecting to the server. If this process is successful,
the UCPs that the server makes available to the WPmSCREEN client will appear on the screen:
8
5.2. “Screen Configuration” Menu
This menu lets you set different parameters for display on the screen of the unit:
Display mode: behaviour of the screen dimming in sleep state, after 10 seconds of inactivity on
your touch screen. The available modes are: ON (always lit), DIMMED and OFF (unlit)
Backlight Intensity : brightness intensity of the screen when it is not in sleep mode
Rotate 180º: allows you to rotate graphics displayed on the screen by 180º to physically install it
upside down. In some cases this can be helpful, since the perceived contrast can be very
different with the screen in one or another position, depending on the viewing angle of the user
relative to the perpendicular of the screen (height of the install, etc.)
Show Panel OSD Keys: enables/disables the superimposed display of the navigation buttons in
the corners of the displayed UCPs. The top corner buttons scroll the panel pages (left and right)
and the bottom corner buttons access the icon bar:
Note: even when the buttons are not displayed, they're still active, so that pressing the top
corners activates the horizontal scrolling between the panel pages and pressing the
bottom corners displays the icon bar. This is an aspect that must be taken into account for
9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.