To use as a blower only, refer to the Operator's Manual
included with the Power Blower unit.
X7671130001
WARNINGDANGER
Read rules for safe operation and all instructions carefully. ECHO provides this Instruction
Manual which must be read and understood for proper and safe operation.
X767000121
05/07
2
INTRODUCTION
Welcome to the ECHO family. This ECHO product was designed and manufactured to provide long life and on-the-job
dependability. Read and understand this manual. You will find it easy to use and full of helpful operating tips and
SAFETY messages.
THEINSTRUCTIONMANUAL
Contains specifications and information for safety, assembly, operation,
maintenance, storage, troubleshooting, and service specific to this
product.
- Additional or Replacement Manuals ........................................................................................1 6
Specifications, descriptions and illustrative material in this literature are as accurate as known at the time of publication,
but are subject to change without notice. Illustrations may include optional equipment and accessories, and may not
include all standard equipment.
• Before opening a chemical container, carefully read, understand, and follow all instructions on the label.
• Carefully read and understand the Operator’s Manual supplied with this unit prior to filling, using, and/or cleaning
this system.
• DO NOT use flammables or corrosives in the system. They can cause damage to the unit, ignite, or explode,
causing serious injury.
CAUTION
Chemical Hazard. Do not ingest ECHO Yard Shield concentrate or diluted chemical mixture. Do not inhale chemical
fumes or sprayed mist. Avoid contact with skin or eyes. Wear appropriate protective clothing and devices including
mask, goggles, and gloves, when working with or around concentrate or diluted chemical mixture. Chemical causes
eye irritation and is harmful if swallowed, inhaled, or absorbed through the skin.
3
• Use only ECHO Mosquito Yard Shield diluted agent with this system.
• Keep spray materials tightly capped, locked up, and out of reach of children and animals.
• Always inspect your system thoroughly before and after each use. Check to be sure pigtail hose is securely attached
and in good condition before mixing chemical in the tank.
• Use only ECHO replacement parts.
• Do not spray on or near electrical installations.
• Keep the work area clear of people and animals.
• Never use the system during windy conditions.
• Do not eat, drink, or smoke while using the system.
• Only mix enough solution for your current application requirements.
• Mix chemical and fill tank on open ground away from blower.
• Do not store system with solution in tank for long periods of time.
• Do not transfer spray materials to other containers.
• Thoroughly clean and rinse tank and spraying assembly after each use.
• Wash thoroughly with soap and water after filling or using the system.
4
DESCRIPTION
Locate all safety decals on your unit. Make sure the decals are legible and that you understand and follow the instructions on them. If a decal cannot be read, a new one can be ordered from your ECHO dealer. See PARTS ORDERING
instructions for specific information.
9
1
8
2
3
4
7
6
11
1.HOSE GUIDES - Route clear supply hose through guides to keep hose out of the way and provide consistent flow
of Yard Shield agent.
2.QUICK DISCONNECT - Disconnect to refill tank with chemical solution.
3.TANK CAP - Covers and seals tank.
4.ADJUSTABLE BACKPACK STRAPS - Allows tank to fit comfortably on your back.
5.BACKPACK TANK - 1.5 gallon backpack tank holds enough diluted solution to cover up to 15,000 square feet.
11.BLOWER TUBE ADAPTER - Install blower tube adapter to use Yard Shield with PB-251.
5
10
CONTENTS
______Backpack tank / hose with quick disconnect valve
______Yard Shield pipe/nozzle assembly
______2 Hose guides
______2 Thumb snaps
______ Tube Adapter
______ Instruction Sheet
ASSEMBLY
ECHO YARD SHIELD SYSTEM
INSTRUCTION MANUAL
5
CONVERTING
SYSTEM
1 .Turn blower pipes counter clockwise to remove from blower.
2.Attach hose guides (A) to each of the two holes on PB-200
3 .Align grooves in Yard Shield pipe with pegs on blower housing
(PB-200)
handle. Secure hose guides by pushing thumb snaps into place.
and slide Yard Shield pipe onto housing. Twist pipe clockwise to
lock into place. Assure clear hose runs along top of pipe.
BLOWERTOYARDSHIELD
A
A
Tip: For best results, do not use Yard Shield pipe for blower-only
application.
4.Route supply hose through hose guides, toward back of blower.
5.Attach hose to tank hose at quick disconnect valve.
6
CONVERTINGYARDSHIELDSYSTEMBACKTO
BLOWER
1.Thoroughly clean and rinse tank and spraying assembly after each
use.
2.Disconnect supply hose from tank hose at quick disconnect valve.
3.Remove supply hose from hose guides.
(PB-200)
4 .Remove Yard Shield pipe by turning counter clockwise.
5 .See PB-200 Operator's Manual for instructions on installing
blower pipes.
CONVERTINGBLOWERTOYARDSHIELD
ECHO YARD SHIELD SYSTEM
INSTRUCTION MANUAL
7
SYSTEM
1 .Release locking ring (C) with a coin or screwdriver, and rotate ring
2 .Remove blower pipes from locking ring.
3 .Align locking ribs (D) on blower pipe adapter with recesses in
(PB-251)
counter clockwise so that lock symbol (A) is at top of ring.
locking ring, and slide adapter into locking ring.
4 . Rotate locking ring (C) clockwise 1/8 turn to lock adapter in place.
5 .Align grooves in Yard Shield pipe with pegs (E) on blower pipe
adapter and slide Yard Shield pipe onto adapter. Twist pipe
clockwise to lock into place. Assure clear hose runs along top of
pipe.
D
C
E
8
6.Route supply hose through handle, toward back of blower.
7.Attach hose to tank hose at quick disconnect valve.
CONVERTINGYARDSHIELDSYSTEMBACKTO
BLOWER
1.Disconnect supply hose from tank hose at quick disconnect valve.
2 .Remove supply hose from handle.
(PB-251)
ECHO YARD SHIELD SYSTEM
3 .Remove Yard Shield pipe by turning counter clockwise.
4 .Release locking ring (C) with a coin or screwdriver, and turn ring
counter clockwise so that lock symbol (A) is at top of ring.
INSTRUCTION MANUAL
9
5 .Remove adapter from locking ring (C).
6 .See Power Blower Operator's Manual for instructions on installing
blower pipes.
10
OPERATION
MIXING
INSTRUCTIONS
YARD SHIELD CHEMICAL CONCENTRATE
PRECAUTIONARY STATEMENTS
HAZARDS TO HUMANS AND DOMESTIC ANIMALS
CAUTION
Causes eye irritation. Harmful if swallowed, inhaled, or absorbed through skin. Avoid contact with skin, eyes, or
clothing. Avoid breathing vapor or spray mist. Wash thoroughly with soap and water after handling and before
eating, drinking, chewing gum, or using tobacco. Remove and wash contaminated clothing before reuse.
ENVIRONMENTAL HAZARDS
This pesticide is extremely toxic to fish. Do not apply directly to water. Do not contaminate water when disposing of
equipment wash waters or rinsate. Drift and runoff may be hazardous to aquatic organisms in water adjacent to
treated areas. This product is highly toxic to bees exposed to direct treatment on blooming crops or weeds. Do not
apply this product or allow it to drift to blooming crops or weeds while bees are actively visiting the treatment area.
CAUTION
Chemical hazard. Wear appropriate protective clothing and devices when working with ECHO Yard Shield concen-
trate. Chemical causes eye irritation and is harmful if swallowed, inhaled, or absorbed through the skin.
ECHO YARD SHIELD SYSTEM
1.Disconnect quick disconnect valve (A) by pushing silver button.
CAUTION
To prevent leaking, mix chemical while tank pigtail hose is disconnected from blower.
INSTRUCTION MANUAL
11
2 .Remove cap from tank. To mix a full tank, pour 1.25 ounces of
Yard Shield concentrate into tank. Fill tank with water to 1.5 gallon
mark. Use graduation marks on concentrate bottle and backpack
tank to mix less than a full tank of solution. Mix only as much as
you will use in one session.
3 .Replace cap.
CAUTION
Spilling hazard. Tank must remain upright at all times, otherwise
contents may leak from cap.
APPLICA TION
W ARNING
Chemical hazard. Chemical causes eye irritation and is harmful if
swallowed, inhaled, or absorbed through the skin. Wear appropriate
protective clothing and devices when working with ECHO Yard
Shield System. Do not spray on or near people or animals. Allow
sprayed area to dry completely before permitting people or animals
to enter.
A
soitaRgnixiM
retaWetartnecnoC
.lag5.1.zo52.1
.lag1.zo38.
.lag5..zo14.
CAUTION
Chemical can blow and drift. Apply on calm days. Otherwise,
sprayed chemical can drift up to 150 meters, causing unintentional
contact.
A full tank of Yard Shield mixture will cover 15,000 square feet.
Aim blower at the ground, bushes, shrubs, hard-to-reach places, and
mosquito breeding grounds. For best results, position blower 3 - 6 feet
from area to be treated and use blower at wide open throttle.
Progress at a normal walking pace, sweeping blower in a side to side
motion, always overlapping passes. Avoid walking directly into spray.
Apply until surfaces are wet but not dripping. People and pets may
safely return to area after application is dry.
Yard Shield will remain effective for up to 3 weeks, as long as surfaces
remain dry. Precipitation will wash Yard Shield away.
12
1.Push silver button on shutoff valve (B) to disengage valve, and
prevent chemical flow.
2 .Start blower. (See PB-200 operator’s manual for step by step
instructions on starting and stopping.)
3 .Put backpack on back, and adjust straps for comfortable fit.
4 .Set blower to half speed or higher.
5.Connect tank hose to clear hose on blower at quick disconnect
valve (A).
NOTE
Assure blower is operating at half speed or higher before engaging
shutoff valve (B).
B
A
6 .Engage shutoff valve (B) to start chemical flow, and begin
spraying.
NOTE
Chemical flow is gravity-fed. Flow will begin when shutoff valve is
connected and backpack is positioned higher than blower.
Stopping Procedure
1.Push silver button on shutoff valve (B) to disengage valve and
stop chemical flow.
2 .Turn blower engine off (Refer to PB-200 operator’s manual.)
B
B
3.Disconnect quick disconnect valve (A).
A
ECHO YARD SHIELD SYSTEM
MAINTENANCE, STORAGE
(According to M86 Web Site (ECHO FAQ's) you can!)
1 .After each use, remove cap and rinse tank thoroughly with clean water.
CAUTION
Never pour pesticides down the toilet drain, into the gutter, or on the ground.
2.Add water to tank and operate system to flush completely.
3.Allow entire system to dry thoroughly before storing.
4 .Always store tank clean and empty in a cool, dry location.
5 .Follow instructions for engine storage in PB-200 Operator's Manual.
INSTRUCTION MANUAL
13
SPECIFICATIONS
Flow Rate .................................................................... 5.3 oz. / minute @ wide open throttle
Spray Type ................................................................. Fine mist, non-adjustable
Tank Capacity ............................................................. 1.5 gallons
Dilution Rate ............................................................... 1.25 oz. Yard Shield Concentrate / 1.5 gallons water
Drying Time ................................................................ Approximately 1 - 4 hours, depending on temperature & humidity
*Cis,trans ratio:........................................................... Min. 35% (±) cis and max 65% (±) trans
**Contains petroleum distillates
14
NOTES
ECHO YARD SHIELD SYSTEM
INSTRUCTION MANUAL
NOTES
15
SERVICING INFORMA TION
PARTS
Genuine ECHO Parts and ECHO REPOWER™ Parts and Assemblies for
your ECHO products are available only from an Authorized ECHO
Dealer. When you do need to buy parts, always have the Model Name
and Number on the front of this manual. (See your Operator's Manual
for Model and Serial Number information to order blower parts. For
future reference, write the model number in the space provided below.
Model No. ______________________
SERVICE
Service of this product during the warranty period must be performed
by an Authorized ECHO Service Dealer. For the name and address of
the Authorized ECHO Service Dealer nearest you, ask your retailer or
call: 1-800-432-ECHO (3246). Dealer information is also available on our
Web Site. When presenting your unit for Warranty service/repairs,
proof of purchase is required.
ECHOCONSUMERPRODUCTSUPPORT
If you require assistance or have questions concerning the application,
operation or maintenance of this product you may call the ECHO
Consumer Product Support Department at 1-800-673-1558 from 8:30 am
to 4:30 pm (Central Standard Time) Monday through Friday. Before
calling, please know the model and serial number of your unit to help
your Consumer Product Support Representative.
DEALER?
Call
1-800-432-ECHO
or
www.echo-usa.com
CONSUMER PRODUCT
SUPPORT
1-800-673-1558
8:30 - 4:30 Mon - Fri C.S.T.
WARRANTYREGISTRATION
To ensure trouble free warranty coverage it is important that you
register your ECHO equipment on-line at www.echo-usa.com. Other
registration options are by automated phone at 1-800-432-3246 or by
filling out the warranty registration card supplied with your unit.
Registering your product confirms your warranty coverage and
provides a direct link between you and ECHO if we find it necessary to
contact you.
ADDITIONALORREPLACEMENTMANUALS
Operator's and Parts Manuals are available by:
• Downloading free from www.echo-usa.com
• Purchasing from your Echo Dealer.
• Sending a check or money order for $2.00 per Parts Catalog or $1.50 per Operator's Manual made payable to ECHO,
INCORPORATED. State on a sheet of paper the model number of the ECHO unit you have, part number of the manual
(if known), your name and address, and mail to the address below.
ECHO, INCORPORATED
400 Oakwood Road
Lake Zurich, IL 60047
WWW.ECHO-USA.COM
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.