ECD MiniM.O.L.E. User Manual

P/N A51-4473-16 Page 1 Rev 4.3.3
MiniM.O.L.E.® rH
Users Help Guide
Rev 4.3.3
Equipment ..........................................................................................................................................................3
Setup ...................................................................................................................................................................7
Quick Start Guide ............................................................................................................................................. 15
Service and Troubleshooting ........................................................................................................................... 21
Specifications ................................................................................................................................................... 22
P/N A51-4473-16 Page 2 Rev 4.3.3
Equipment
The MiniM.O.L.E.® rH provides one Relative Humidity (rH) and one Temperature channel of static data logging, suitable for Dry Cabinet, manufacturing plant ambient monitoring. With LCD Display, Magnet start, 1 second to 10 day sample rate.
Features/Functions:
 Start Switch: This is an internal switch that is triggered when using the Start Magnet.
 Relative Humidity (rH) & Temperature Sensors: These are an external Relative Humidity Type
“K” Thermocouple sensor. Both are protected by an plastic grid.
 Data Contacts: When connected to the USB Dock Station, these contacts transfers data to the
computer.
P/N A51-4473-16 Page 3 Rev 4.3.3
 LCD Display: Provides the feature of displaying the last log reading or current reading without
State:
Action:
LED
LCD Display
Ready
Indicates Profiler is "Ready" to record data
Quick flashing
Start
Indicates Profiler is starting recording process.
Quick flashing Recording (rH)
Indicates Profiler is recording rH data.
Flashing at log interval
Recording (Temperature)
Indicates Profiler is recording temperature data.
Flashing at log interval
End
Indicates Profiler recording process has ended
No illumination Data Transfer
Indicates data is being uploaded or downloaded
Steady Illumination
rH/Temperature display
downloading. Refer to the table below for complete features.
P/N A51-4473-16 Page 4 Rev 4.3.3
USB Dock Station
The USB Dock Station is required for the MiniM.O.L.E.® rH to communicate with the M.O.L.E.® MAP software. The USB cable connects to a computer USB Port and then the user inserts the MiniM.O.L.E.® rH into the station cradle mating the brass contacts from both units.
P/N A51-4473-16 Page 5 Rev 4.3.3
Start Magnet
The MiniM.O.L.E.® rH Start Magnet activates the unit by triggering an internal start switch. This magnet is used only to initiate recording data after the unit is configured using the Setup Instrument wizard. To Stop recording data, the user downloads the data run by using the Read Instrument wizard or the memory limit has been reached.
P/N A51-4473-16 Page 6 Rev 4.3.3
Setup
The M.O.L.E.® MAP software must be installed prior to communications setup. (Refer to Software Installation for more information).
Communications Setup
Prior to operation the M.O.L.E. Profiler must be configured to properly communicate with the M.O.L.E.® MAP Software.
To connect the M.O.L.E. Profiler:
1) Insert the USB computer interface cable from the Dock Station into a computer USB Port.
P/N A51-4473-16 Page 7 Rev 4.3.3
2) Place the M.O.L.E. Profiler into the USB Dock Station, making sure that the two metallic
Typically the device drivers are already installed on Windows 7 & XP operating systems. In some cases the user will be required to manually install them.
contacts on the bottom of the M.O.L.E. Profiler are aligned with the contact pins on the USB Dock Station and that the M.O.L.E. Profiler is firmly seated.
P/N A51-4473-16 Page 8 Rev 4.3.3
3) Browse to the \DriverMMrH\Installer\ folder on the M.O.L.E.® MAP Software installation CD.
P/N A51-4473-16 Page 9 Rev 4.3.3
4) To install the device drivers on a 32-bit operating systems, double-click
Depending on your operating system security settings, a Security Warning dialog box may appear. Click the Yes command button to continue.
VCP_Driver_Installer.exe. For 64-bit operating systems, double-click VCP_Driver_Installer_x64.exe.
P/N A51-4473-16 Page 10 Rev 4.3.3
5) “VCP Driver Installer.exe” extracts DPInst.exe and driver files into a temporary folder then starts the installation wizard.
6) Click the Next command button.
P/N A51-4473-16 Page 11 Rev 4.3.3
7) The wizard starts device driver installation.
P/N A51-4473-16 Page 12 Rev 4.3.3
8) When the Installation has completed, select the Finish command button.
9) Start the software program by either double-clicking the M.O.L.E.® MAP software icon or selecting it from the ECD program sub-menu.
P/N A51-4473-16 Page 13 Rev 4.3.3
10) On the M.O.L.E. menu, click the Select Instrument command.
If the software does not detect a M.O.L.E. Profiler, using the communication cable connect it to the computer and click the Scan for Instruments command button to search again. M.O.L.E.® MAP software allows multiple instruments to be connected to a computer at one time. Selecting the Scan for Instruments command button will detect all instruments and display them in the dialog box. If no instrument is detected the software displays all of the Demonstration thermal profilers to select from.
11) Select the MEGARIDER PTP® instrument from the dialog box.
12) Click the OK command button to accept or Cancel to quit the command without selecting the instrument.
13) Turn the PTP® TX power by removing the On/Off Male Plug connector from the Female On/Off Power connector.
P/N A51-4473-16 Page 14 Rev 4.3.3
Quick Start Guide
This is available when in Engineer Mode.
If the desired Environment is not displayed on the Environment Sidebar, the user can use either the Open Environment Toolbar button or select the Open Environment Folder command from the File Menu.
This Wizard guides the user through a typical process on how to set a MiniM.O.L.E.® rH up to record data.
To set an instrument up:
1) Connect the USB Dock Station to the computer and insert the M.O.L.E. Profiler into the dock cradle. Refer to the Communications Setup topic for your specific M.O.L.E. Profiler for
more information.
2) Set an Environment related for the type of experiment that is being performed. Either open an existing Environment Folder or create a new one.
P/N A51-4473-16 Page 15 Rev 4.3.3
3) On the M.O.L.E. menu, click Setup Instrument and the workflow wizard appears.
When navigating through the wizard, the step list on the left uses a color key to inform the user of the current step, steps that have been completed and remaining steps.
Current
Completed
Remaining
If the software does not detect a M.O.L.E. Profiler, using the communication cable connect it to the computer and click the Scan for Instruments command button to search again. M.O.L.E.® MAP software allows multiple instruments to be connected to a computer at one time. Selecting the Scan for Instruments command button will detect all instruments and display them in the dialog box. If no instrument is detected the software displays all of the Demonstration thermal profilers to select from.
4) Select the desired instrument from the dialog box. If there is none displayed, select the Scan for Instruments command button to detect all connected instruments.
5) Select the Next command button.
P/N A51-4473-16 Page 16 Rev 4.3.3
6) Set instrument name, recording interval and if the sensor is to be ON or OFF.
7) Select the Next command button to send the data listed in the dialog box to the instrument.
P/N A51-4473-16 Page 17 Rev 4.3.3
8) Set the assembly information such as part number, board size, sensor locations and a product image. This assembly information can then be loaded and saved from/to a an (*.XMA) file.
 Load: This command buttons loads an existing assembly (*.XMA).
 Save: This command button saves the current sensor locations and image to an (*.XMA)
file that is then available to be loaded for future data runs.
P/N A51-4473-16 Page 18 Rev 4.3.3
If the user specifies a product image, clicking the Enlarge command button displays the Set Sensor Locations dialog box where the user can specify the locations of each sensor. To move sensor locations, drag the sensor markers to the approximate location where the sensors are attached.
9) Click the Next command button.
P/N A51-4473-16 Page 19 Rev 4.3.3
10) Verify the instrument status. This dialog box displays the health of the M.O.L.E. Profiler such as battery charge, internal temperature, thermocouple temperatures. If the user selects the Show Critical command button the dialog box will only display items that will prevent the user from completing a successful data run.
11) Select the Finish command button to complete the Setup Instrument wizard.
The MiniM.O.L.E.® rH is now ready to collect data.
P/N A51-4473-16 Page 20 Rev 4.3.3
Service and Troubleshooting
The following service and calibration instructions are for use by qualified personnel only. Refer to the Safety>Operators Safety Information prior to performing any service.
Telephone:
+(1) 800.323.4548
+(1) 503.659.6100
FAX:
+(1) 503.659.4422
Email:
ecd@ecd.com
Internet:
http://www.ecd.com
This section covers maintaining and troubleshooting hardware, sensors, M.O.L.E. Profiler Power Pack, Software, Wiring, and other parts of the system.
Service Troubleshooting:
Decide if the problem is with the Hardware, Communications, or Software.
 If the problem occurs while attempting to log data, the Hardware may be faulty.
 If the problem occurs while attempting to communicate between M.O.L.E. Profiler and the
computer, the Communications links may be faulty.
 If the problem occurs while attempting to use a software function, the software may be faulty.
Once it has been determined what item is causing the problem, refer to the appropriate service section. Start at the top of the list and work your way down.
Here is how to contact ECD:
If you still have problems, let us help you. We offer many ways to service your problems. You can call our Service/Test technicians, visit our web site to view our FAQ section (Frequently asked Questions) or send us e-mail explaining your problem in detail.
When calling our Service/Test technicians or sending us e-mail, please include the following information:
 Product Description (i.e. SuperM.O.L.E.® Gold 2, WaveRIDER® NL 2)  Product Serial Number  M.O.L.E.® MAP Software Version
P/N A51-4473-16 Page 21 Rev 4.3.3
Power Source
PHYSICAL DIMENSIONS:
0.37 in. x 3.5 in. x 6 in. (9.41 mm x 89 mm x 152.4 mm)
TEMPERATURE MEASUREMENT RANGE:
-40 to 70°C (-40 to 158°F)
RH RANGE:
0 to 100% RH
*WARNING: Exceeding this temperature may permanently damage the equipment!
ACCURACY:
± 0.35°C (from -40°C to 0°C) or ±0.63°F (from -40°F to +32°F) ±0.25°C (from 0° to +70°C) or ±0.45° (from +32°F to +158°F) Humidity ±3% Resolution: 0.1
PROGRAMMABLE SAMPLING PERIOD:
1 second to 10 days
NUMBER OF SAMPLES PER CHANNEL:
32,000 (16,000 per sensor)
POWER SUPPLY:
3.6V ½ AA Lithium battery
The MiniM.O.L.E.® rH is powered by a 3.6 volt ½ AA lithium battery. If the LCD display is dim or does not illuminate, check the battery to see if it has become discharged. Always replace with SAFT lithium battery (LS 1425) or the equivalent specified.
Specifications
Electrical/Mechanical Spec:
P/N A51-4473-16 Page 22 Rev 4.3.3