Eccotemp EM-2.5, EM-4.0, M-6.0 Use And Care Manual

Page 1
Page 2
2
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
Important Safety Instructions ________________________________________________ 2
Technical Data _________________________________________________________ 3-4
Technical Description ______________________________________________________ 6
Installation Instructions __________________________________________________ 6-10
Plumbing Connections _____________________________________________________ 7
Temperature & Pressure Relief Valve __________________________________________ 7-8
Filling The Water Heater ____________________________________________________ 9
Electrical Connections _____________________________________________________ 9
Instructions For Use ______________________________________________________ 10
Maintenance Instructions ___________________________________________________ 11
Troubleshooting ________________________________________________________ 14
Schematic & Parts List __________________________________________________ 15-16
Warranty _______________________________________________________ Back Cover
Table of Contents
Page 3
3
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
1. READ All.. INSTRUCTIONS BEFORE USING THIS WATER HEATER.
2. This water heater must be grounded. Connect only to properly grounded outlet. See GROUNDING INSTRUCTIONS found on page 10.
3. Install or locate this water heater only in accordance with the provided installation instructions.
4. Use this water heater only for its intended use as described in this manual.
5. Do not use an extension cord with this water heater. If power is not available adjacent to the water heater, contact a qualified electrician to have a receptacle properly installed.
6. As with any appliance, close supervision is necessary when used by children.
7. Do not operate this water heater if it has a damaged cord or plug, if it is not working properly, or if it has been damaged or dropped.
8. Only qualified service personnel should service this water heater. Contact nearest authorized service facility when questions arise or service is required.
9. If the unit is installed in an area where there is a potential for freezing, the instructions found in the subsequent section SETTING THE FREEZE PROTECTION
must be followed.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: When using electrical appliances, safety precautions
to reduce the risk of fire, electric shock or injury to persons should be followed, including:
The manufacturer and/or distributor is not responsible for damages caused by improper installation, or failure to follow the instructions in this manual. A QUALIFIED, LICENSED TECHNICIAN MUST ALWAYS INSTALL THE WATER HEATER
AND CONDUCT ALL SUBSEQUENT SERVICE WORK AND/OR MAINTENANCE.
KEEP THESE INSTRUCTIONS
FILL THE TANK COMPLETELY FULL WITH WATER AND HAVE WATER FLOWING FROM THE HOT WATER FAUCET BEFORE ACITVATING POWER TO THE HEATER FOR THE FIRST TIME OR DAMAGE WILL RESULT.
IMPORTANT!!!!
Page 4
4
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
Technical Data
MODEL
Capacity Voltage Power @ 120 VAC Max. Water Pressure Weight (empty) Amperage Phases
gallons VAC Watts psi lbs. Amps
EM2.5
2.5 110-120 1440 150 20 12 1
EM4
4.0 110-120 1440 150 24 12 1
EM6
6.0 110-120 1440 150 26 12 1
Page 5
5
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
Model I Barang
EM2.5 EM4 EM6
A(mm)
14. 7”
14. 5•
17. 7”
B(mm)
11. 7”
14. 5”
17. 7”
C(mm)
10. 2”
12. 9”
14. 6”
dispositif de protection contre la surchauffe
thermostat
lumière indicatrice
Element chauffant
fiche d’alimentation
EM2.5/EM4
EM6
Page 6
6
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
GENERAL INFORMATION
The Seisco Mini-Tank Water Heaters can be used in most under the counter, point of use applications. EM models are designed to supply hot water for all hand wash and kitchen sinks in a residential, commercial or industrial environment.
EM models can replace traditional central hot water heaters thereby conserving water and reducing energy waste. EM models can also be plumbed in series with the central water heater and act as a booster.
The Seisco Mini-Tank Water Heaters are lightweight and compact and manufactured for easy installation. EM models can be mounted on the wall with included hardware, or freestanding.
EM models are designed to operate at 150-psi maximum water pressure. Install a pressure-reducing valve if your water pressure is greater than 150-psi.
CAUTION!: The manufacturer cannot be responsible for the damage caused by improper installation or by failure to follow instructions in this manual. Comply with the Installation Instructions before connecting to electrical outlet.
CAUTION!: The thermostat has been pre-set at the factory between 105m ( 41 C) and 113m ( 45 C).
CAUTION!: Hydrogen gas can be produced in a hot water system served by this heater that has not been used for a long period of time (generally 2 weeks or more). Hydrogen gas is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that the hot water faucet be opened for several minutes at the nearest and most distant sink being served by this water heater before using any electrical appliance connected to the hot water system {i.e. Dishwasher). If hydrogen gas is present, there will probably be an unusual sound such as air escaping through the faucet as the water begins to flow. There should be no smoking or open flame near the faucet at this time.
WARNING: Installer should review the contents of this manual with the owner upon completion of the installation, and the manual should remain with the owner and placed in a location close to the water heater.
Page 7
7
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
TECHNICAl DESCRIPTION
There are three Seisco Mini tank models, a 2.5-gallon, a 4-gallon and a 6-gallon model. The pressure vessel (water tank) is welded, glass lined steel and is equipped with an anode rod. The water heater is equipped with a thermostat and a high limit temperature switch. A temperature/pressure relief valve is supplied with the unit.
INSTALLATION INSTRUCTIONS
MODELS: EM2.S - EM4 - EM6
A licensed professional must complete the installation adhering to all state and local codes. The manufacturer will not be liable for any damages because of failure to comply with these installation instructions or because of improper installation performed by an unqualified installer.
CHOOSE A LOCATION that allows ease of access for maintenance ideally with at least 9 clearance at the top from the ceiling, cabinet, or any adjacent walls.
WALL MOUNTING
Fasten the supplied mounting bracket to the wall. Use screws that are suitable for the wall material and the weight of the water heater filled to capacity (EM2.5-41 lbs.; EM4-57 lbs.; EM6-76 lbs.). Hang the water heater on the bracket and pull downwards on the water heater to ensure that both ~ingers?of the bracket are seated in the mounting slots.
Confirm your water piping orientation (hot and cold) before wall mounting. ONLY INSTALL IN VERTICAL POSITION.
Heater can also sit on the floor. ONLY INSTALL IN VERTICAL
POSITION! EM models can be installed under the sink.
Page 8
8
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLUMBING CONNECTIONS
Connect the cold-water inlet pipe to the inlet nipple (marked with a blue ring) and the hot water outlet pipe to the outlet nipple (marked with a red ring).
IMPORTANT: If Water pipes are copper or bronze, use dielectric connections to prevent corrosion. Failure to provide dielectric insulation may result in premature tank or nipple failure and may void your warranty. Ensure that the water heater is installed in a level position. Install a shut off valve on the cold water side of the water heater. The valve is for servicing and the valve should be in the open position when the water heater is in operation. In order to protect the water heater from heat damage due to soldering, solder a piece of tubing to a threaded UNION fitting before screwing the UNION to the tank.
DO NOT APPLY HEAT DIRECTLY TO INLET OR OUTLET CONNECTIONS.
TEMPERATURE AND PRESSURE RELIEF VALVE:
CAUTION!: Install the Temperature/Pressure Relief Valve supplied with the water heater!
Install a discharge pipe from the temperature/pressure relief valve terminating at a sink or drain. DO NOT CAP OR PLUG THE END OF THE DISCHARGE PIPE. THE DISCHARGE PIPE MUST BE UNOBSTRUCTED AND FULLY SIZED.
A nationally recognized test lab that maintains periodic inspections of the listed equipment and meets the requirements for relief valves certifies the T/P valve and automatic shut off devices for hot water supply systems ANSI 121.22-1979.
The T/P valve is marked with a maximum pressure, which does not exceed the maximum working pressure of the water heater (150 PSI).
Install the T /P valve into the threaded opening at the top of the water heater and orient the discharge tubing so that any discharge from the valve will exit within 6 inches above, or at any distance below the structural floor, and cannot contact any live electrical part.
Page 9
9
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
T /P Valve Discharge pipe:
1. Must NOT be smaller in diameter than the outlet diameter of the valve, or have any reducing couplings.
2. Must NOT be plugged or blocked.
3. Must be made of suitable material for hot water.
4. Must not be over 15 in length.
5. Must not have more than two elbows.
6. Must terminate at an adequate drain.
7. Must not have a shut off valve between relief valve and tank or relief valve and termination of discharge.
CLOSED SYSTEM THERMAL EXPANSION: Periodic discharge of the T /P relief valve or failure of the element gasket may be due to thermal expansion in a closed water supply system. The water utility supply meter may contain a check valve, backflow preventer or water pressure-reducing valve that will create a closed water system. During the heating cycle of the water heater, the heated water expands causing pressure inside the water heater to increase. The T /P relief valve may discharge hot water under these conditions that results in a loss of energy and a build up of lime on the relief valve seat.
To prevent this from happening, there are two recommendations:
1. Install a diaphragm-type domestic hot water expansion tank (suitable for potable water) on the cold water supply line. The expansion tank must have a minimum capacity of 1.5 U.S. gallons for every 50 gallons of stored water.
2. Install a 125-PSI pressure relief valve in the cold water supply line. Make sure the discharge of this valve is directed to an open drain and protected from freezing. Contact your local water utility or plumbing inspector for information on how to control this situation. Never plug the outlet of the relief valve.
Page 10
10
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
FILLING THE WATER HEATER
CAUTION!: Before powering the water heater, be sure that the system is completely filled with water and All AIR IS REMOVED. If Water pipes
Before connecting the power, fill the tank and system with water and check for leaks. To be sure that all air is out of the water system, open the hot water faucets on your fixtures until constant water flows. Any air remaining in the tank will cause the water heater element to fail.
filling the water heater:
1. Open the hot water faucet.
2. Open the cold water supply valve.
3. When continuous water flows out of the faucet, the tank is filled.
4. Close the hot water faucet.
5. Check entire system for leaks.
ELECTRICAL CONNECTIONS
To be certain that all of the air is out of the water heater, open the HOT water faucet on your fixtures until constant water flows from them. If air remains in the tank, the element will be damaged when the electric cord is plugged in.
Connect the water heater to a GROUNDED OUTLET. The water heater is fitted with a power cord that is intended to plug into a grounded 110-120 V/AC receptacle. Adhere to all pertinent State and local codes. Install the correct size circuit breaker into the master panel. The Seisco EMT water heater was manufactured and wired in accordance with UL requirements.
The water heater is equipped with an overheat limiting device with a manual reset. Also known as the temperature high limit, this device has been factory installed to interrupt the power supply in the event of a thermostat failure.
THIS WATER HEATER IS DESIGNED FOR 110-120V SERVICE - DO NOT CONNECT TO ANY OTHER VOLTAGE.
Failure to use proper voltage may result in personal injury and/or property damage. If the supplied electrical power cord is either damaged or not long enough, do NOT use an extension cord. Have a licensed electrician replace the power cord.
Page 11
11
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
INSTRUCTIONS FOR USE
CONGRATULATIONS! You are now ready to use your water heater. Run the hot water at a nearby sink and evaluate the hot water temperature. Make any temperature adjustment using the section below:
SETTING THE THERMOSTAT:
The water heater is equipped with an adjustable thermostat that once set will automatically control water temperature. The lamp remains illuminated while the water is being heated. If the water in the tank is at the desired temperature the lamp will NOT be illuminated.
The temperature-adjusting knob will increase the temperature by turning the knob clockwise and decrease the water temperature by turning the knob counter clockwise.
When not being used for a lengthy period of time, you can conserve energy by reducing the water temperature setting.
SETTING THE FREEZE PROTECTION:
When the water heater is not being used for an extended period of time and there is a risk of freezing, either unplug and drain the water heater OR turn the thermostat knob to the snowflake position to guard against freezing. This position will keep the internal water temperature above the freezing point.
Page 12
12
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
MAINTENANCE INSTRUCTIONS
Do not attempt to repair this water heater yourself. Call a qualified service person for service assistance. Always unplug the power supply cord when the water is turned off or when servicing or draining the water heater.
Before calling for service, first confirm that the water heater is properly filled and that 110VAC power has not been interrupted.
WARNING: Before servicing or cleaning the water heater, disconnect the power cord from the electrical outlet.
NOTE: For most maintenance operations, the water heater will be drained. In all cases before draining you must unplug the power cord.
DRAINING AND REMOVING THE WATER HEATER:
1. Unplug the water heater.
2. Open a hot water faucet to let hot water run out. Allow water to flow until water is no longer hot.
3. Turn off the cold water supply to the water heater.
4. Close the hot water faucet.
5. Disconnect the water heater from both the hot and cold water connections.
6. If possible siphon out remaining water.
7. Carefully detach the water heater from the wall.
8. Tilt the water heater to drain remaining water out of the heater.
REMOVING THE HEATING ELEMENT:
1. Turn off power supply; unplug water heater power cord and drain (see above).
2. Remove cover.
3. Remove all the line wires from the heating element.
4. Unscrew the heating element retaining nuts.
5. Remove the element.
Page 13
13
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
DESCALING THE HEATING ELEMENT:
Scale deposits can affect the heating capability of the element. Heavy scale can even cause the element to burn out. The element can be descaled chemically or manually.
1. Remove the heating element (see above).
2. To descale chemically, soak the heating element in white vinegar or other descaling solution and then rinse well with fresh water.
3. To descale manually, let element dry and then using a non metallic brush similar to a tooth brush; brush the residue from the element. Avoid damaging the surface of the element.
4. Reinstall the element and gasket.
5. Refill tank with water before turning on the power to the water heater.
REPLACING THE HEATING ELEMENT:
1. Unplug and drain the water heater (see prior instructions).
2. Remove heating element noting original positions of all connections.
3. Install new element with gasket making sure the new element and gasket are positioned correctly.
4. Tighten retaining nuts and make the wire connections to their original locations.
CHANGING THE THERMOSTAT:
1. Unplug the water heater from the electrical outlet.
1. Drain and remove the water heater. (see page 12)
2. Remove the bottom panel of the water heater and remove the panel.
3. Remove thermostat knob and unscrew two retaining screws. It maybe necessary to pry the knob off of the thermostat spindle. Now remove front panel.
4. Disconnect the push-pull wire connectors on the thermostat noting which connector goes to which terminal. Terminals are marked.
5. Remove the thermostat probe from the well.
6. Install new thermostat, attach wires and tighten screws.
Page 14
14
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
RESETTING THE HIGH LIMIT SWITCH:
The high limit safety shut off switch will shut the water heater down when water temperatures exceed 190 F. Power is automatically turned off to the heating element. The shut off device may activate as a result of a power outage or an electrical storm.
NOTE: Do not attempt to reset the high limit switch without first allowing the water heater to cool down the high temperature water inside the heater.
WARNING: Do not tamper with the reset button to override overheating shut down.
1. Unplug the water heater from the electric outlet.
2. Drain and remove the water heater. (see page 12)
3. Remove six screws retaining the bottom panel of the water heater and remove the panel. Locate the high limit reset button.
4. Depress the small red button in the center of the junction box, replace the bottom panel and place the water heater back into service.
NOTE: A lower temperature setting saves energy and reduces the risk of scalding.
CAUTION!: Call a technician if the high limit needs to be reset frequently.
Page 15
15
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
TROUBLESHOOTING
PROBLEM: Water does not get hot
1. Make sure the power supply is on and working.
2. If light does not come on, check that the reset button is pushed in; follow steps from previous section.
3. If the indicator light is illuminated, but water temperature does not get hot at the sink, test for a plumbing crossover as follows; shut off cold water supply to water heater and open hot water tap. There should be no water flowing. Any continuous flow indicates a cross over which will effect the temperature and will need to be corrected.
4. If there is no crossover, then replace the heating element (see previous sections).
PROBLEM: Indicator light not on
1. If the light does not come on, but water gets hot, check for faulty bulb.
2. Check reset button; follow steps from previous section.
PROBLEM: Brown water
1. Brown or rusty water indicates a spent anode rod. Replace anode rod.
PROBLEM: Odor in water
1. Smelly water could be due to an unusual reaction between local water and the heaters anode rod. Check anode rod.
PROBLEM: Water is too hot
1. Turn the temperature knob counter clockwise to a lower temperature setting. If temperature does not lower within 60 minutes, then replace thermostat.
PROBLEM: Water is not hot enough
1. Under Instructions for Use, see Setting the thermostat.
PROBLEM: Water is leaking
1. Unplug water heater from 110 VAC outlet.
2. Check water fittings and T&P fitting in the top of the tank.
3. Remove cover and inspect heating element gasket.
Page 16
16
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
Page 17
17
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locator: Eccotemp.com/locator
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
Page 18
Loading...