Eccotemp i12 Use & Care Manual

Page 1
Page 2
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
WARNING: If the information in these instructions is not followed exactly,
a re or explosion may result causing property damage, personal injury
or death.
the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your
building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re department.
Installation and service must be performed by a qualied installer
service agency or the gas supplier.
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
i12-NG
SERIAL #:
TYPE GAS:
NATURAL GAS
ONLY Minimum Inlet Gas Pressure:
Minimum Input Rang (Btu per hour):
Maximum Input Rang (Btu per hour):
Voltage:
120 Volts
Maximum Inlet Gas Pressure:
Frequency:
60 Hz
Manifold Pressure:
Amps:
Less than 12 Amperes
Maximum Working Pressure:
Recovery
Rang:
SUITABLE FOR WATER (POTABLE) HEATING ONLY
As used in this standard, the quanty of water obtained by mulplying the manufacturer's input rang in Btu per hour by the thermal efficiency and dividing the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and a nominal specific heat for water of 8.25 Btu per gallon per degree F.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance must be installed in accordance
with local codes or, in the absence of local
codes, the Naonal Fuel Gas Code, Natural Gas
and Propane Installaon Code
80,000
20,000
4” w.c (1Kpa)
10.5'' w.c (2.61Kpa)
3.05'' w.c (0.76Kpa)
150 psi
The temperature and pressure relief valve provided by the manufacturer shall be installed at the me of installaon of the heater in the locaon specified by the manufacturer. Local codes shall govern installaon of relief devices. For safe operaon of the water heater, the relief valve must not be removed or plugged.
INDOOR USE ONLY
The unit must be installed on a fire retardant area, and must be away from all combusble materials. Clearance should be 1.75  to the le and right side of combusble materials, and
6.75  to the front.
Open on three sides and an overhead clearance of 36”
Not recommended in excess of 3,800 . above sea level.
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
i12-LP
SERIAL #:
TYPE GAS:
LIQUID PROPANE
ONLY Minimum Inlet Gas Pressure:
Minimum Input Rang (Btu per hour):
Maximum Input Rang (Btu per hour):
Voltage:
120 Volts
Maximum Inlet Gas Pressure:
Frequency:
60 Hz
Manifold Pressure:
Amps:
Less than 12 Amperes
Maximum Working Pressure:
Recovery
Rang:
SUITABLE FOR WATER (POTABLE) HEATING ONLY
As used in this standard, the quanty of water obtained by mulplying the manufacturer's input rang in Btu per hour by the thermal efficiency and dividing the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and a nominal specific heat for water of 8.25 Btu per gallon per degree F.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance must be installed in accordance
with local codes or, in the absence of local
codes, the Naonal Fuel Gas Code, Natural Gas
and Propane Installaon Code
80,000
20,000
9'' w.c
(2.24 Kpa)
13'' w.c
(3.23Kpa)
4.93'' w.c (1.22Kpa)
150 psi
The temperature and pressure relief valve provided by the manufacturer shall be installed at the me of installaon of the heater in the locaon specified by the manufacturer. Local codes shall govern installaon of relief devices. For safe operaon of the water heater, the relief valve must not be removed or plugged.
INDOOR USE ONLY
The unit must be installed on a fire retardant area, and must be away from all combusble materials. Clearance should be 1.75  to the le and right side of combusble materials, and
6.75  to the front.
Open on three sides and an overhead clearance of 36”
Not recommended in excess of 3,800 . above sea level.
Page 3
1
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Use & Care Manual
With Installation Instructions for the Installer
Residential Indoor Gas 80,000 BTU Max Input @ 3GPM
Tankless Water Heater
WARNING: This water heater may not be suitable for use in manufactured (mobile) homes! Please check local code restrictions pertaining to permanent/xed installations in manufactured homes
in your area.
The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water heater; and two, to the owner-operator, to explain the features, operation, safety precautions, maintenance and troubleshooting of the water heater. This manual also includes a parts list.
It is imperative that all persons who are expected to install, operate or adjust this water heater read the instructions carefully so they may understand how to perform these operations. If you don’t understand these instructions or any terms within it, seek professional advice.
Any questions regarding the operation, maintenance, service or warranty of this water heater should be directed to the seller from whom it was purchased. If additional information is required, refer to the section on If You Need Service.
Do not destroy this manual. Please read carefully and keep in a safe place for future reference.
Recognize this symbol as an indication of Important Safety Information!
California Proposition 65 Warning: This product contains chemicals known to the
State of California to cause cancer, birth defects or other reproductive harm.
WARNING: If the information in these instructions is not followed exactly, a re or explosion
may result causing property damage, personal injury or death.
FOR YOUR SAFETY!
Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury, or death. Refer to this manual. Installation and service must be
performed by a qualied installer, service agency
or the gas supplier.
DO NOT store or use gasoline or other ammable
vapors or liquids or other combustible materials in the vicinity of this or any other appliance. To do so
may result in an explosion or re.
WHAT TO DO IF YOU SMELL GAS
• DO NOT try to light any appliance.
• DO NOT touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the
re department.
• DO NOT return to your home until authorized by
the gas supplier or re department.
Page 4
2
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
FOR YOUR RECORDS
Write the model and serial numbers here: #_______________________________
#_______________________________
You can nd them on a label on the appliance
and/or packaging.
Staple sales slip or canceled check here.
Proof of the original purchase date is needed to obtain service under the warranty.
READ THIS MANUAL
Inside you will nd many helpful hints on how
to use and maintain your water heater properly. A little preventive care on your part can save you time and money over the life of your water
heater. You’ll nd many answers to common
problems in the Troubleshooting Guide. If you
review the chart of Troubleshooting Tips rst,
you may not need to call for service.
READ THE SAFETY INFORMATION
Your safety and the safety of others are very important. There are many important safety messages in this manual and on your appliance.
Always read and obey all safety messages. This is the safety alert symbol. Recognize this symbol as an indication of Important Safety Information! This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER”,
“WARNING”, “CAUTION” or “NOTICE”.
These words mean:
DANGER - An imminently hazardous situation that will result in death or serious injury.
WARNING - A potentially hazardous situation that could result in death or serious injury and/or damage to property.
CAUTION - A potentially hazardous situation that may result in minor or moderate injury.
NOTICE: Attention is called to observe a specied procedure or maintain a specic condition.
Safety Information
Safety Precautions .................6
LP Gas Models .......................5
Installation Instructions
Location ..............................7-9
Water Connections ......... 10-11
Relief Valve.............................11
Gas Supply..............................12
Leak Testing............................12
High Altitude ......................... 12
Typical Installation ..........13-14
Venting ............................ 15-19
Electrical Connection ............20
Pipe Insulation .......................21
Installation Checklist ............22
Operating Instructions
Start Instructions ........... 23-24
Water Temperature ..............25
Temperature Memory.......... 25
Care and Cleaning
Maintenance ........................ 26
Housekeeping ..................26-27
Vent Inspection..................... 27
Extended Shut-Down ...........27
No Anti-freezing....................27
Draining .......................... 27-28
Troubleshooting Tips
Before You Call .................... 29
Error Code Guide ..................30
Customer Service
Parts List................................31
Page 5
3
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING
Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater. It may save you time and money. Pay particular attention to the Safety Instructions. Failure to follow these warnings could result in serious bodily injury or death. Should you have problems understanding the instructions in this manual, or have any questions, STOP, and
get help from a qualied service technician, or the local gas utility.
DANGER!
PROPERLY INSTALL WATER HEATER
Failure to properly install the water heater outdoors as outlined in the Installation Instructions in this manual can result in unsafe operation of the water heater. To
avoid the risk of re, explosion, or asphyxiation from carbon monoxide, never
operate this water heater unless it is installed properly and has an adequate
air supply for proper operation. Be sure to inspect the ue terminal for proper
installation at initial start-up; and at least annually thereafter. Refer to the Care
and Cleaning section of this manual for more information regarding ue terminal
inspection.
WARNING!
Gasoline, as well as other ammable materials and liquids (adhesives, solvents,
paint thinners etc.) and the vapors they produce are extremely dangerous. DO NOT
handle, use or store gasoline or other ammable or combustible materials any
where near or in the vicinity of a water heater or any other appliance. Be sure to read and follow the labels on the water heater, as well as the warnings printed in this manual. Failure to do so can result in property damage, bodily injury or death.
Vapors from ammable liquids will explode and catch re causing death or severe burns.
Do not use or store ammable products
such as gasoline, solvents or adhesives in the same room or area near the water heater.
Keep ammable products :
1. Far away from heater
2. In approved containers
3. Tightly closed
4. Out of children ‘s reach
Water heater has a main burner ame. The main burner ame
1. Can come on at any time and
2. Will ignite ammable vapors.
Vapors:
1. Cannot be seen
2. Are heavier than air
3. Go a long way on the oor
4. Can be carried from other rooms to the
main burner ame by air currents.
Installation:
Do not Install water heater where ammable products will be stored or used unless the main burner ame Is at least 18” above the oor. This will reduce, but not eliminate, the risk of vapors being ignited by the main burner ame.
Read and follow water heater warnings and Instructions. If owners manual is missing, contact the retailer or manufacturer.
Page 6
4
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING
DANGER!
WATER TEMPERATURE SETTING
Safety and energy conservation are factors to be considered when selecting the water temperature setting. Water temperatures above 125°F can cause severe burns or death from scalding. The thermostat is adjusted to its lowest temperature position when shipped from the factory. Be sure to read and follow the warnings outlined on the label pictured below.
The chart shown above may be used as a guide in determining the proper water temperature for your home
DANGER: Households with small children,
disabled, or elderly persons may require a 120°F. or lower temperature setting to prevent contact
with”HOT” water.
Maximum water temperature occurs while
burner is on. To nd water temperature being
delivered, turn on a hot water faucet and place a thermometer in the water stream and read the thermometer.
The temperature of the water at the outlet of the water heater can be regulated by setting the temperature on front side of water heater. The water heater was set at 110°F before it was shipped from the factory.
NOTICE: When this water heater is supplying
general purpose hot water requirements for use by individuals, a thermostatically controlled mixing valve for reducing point of use water temperature is recommended to reduce the risk of scald injury. Contact a licensed plumber or the local plumbing authority for further information.
The factory recommended operating temperatures are between 90°F and 140°F.
Water Temperature
120°F 125°F 130°F 135°F 140°F 145°F 150°F 155°F
Time To Produce a Serious Burn
More than 5 minutes
1 1/2to 2 minutes
About 30 seconds
About 10 seconds Less than 5 seconds Less than 3 seconds
About 1 1/2 seconds
About 1 second
Time/Temperature Relationship in Scalds
Table cour tesy of Shriners Burn Institute
Water temperature over 125°F can cause severe burns instantly or death from scalds. Children, disabled and elderly are at highest risk of being scalded. See instruction manual before setting temperature at water heater. Feel water before bathing or showering. Temperature limiting valves are available, see manual.
Page 7
5
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
DANGER!
NATURAL GAS AND LIQUEFIED PETROLEUM MODELS
Both LP and natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or recognize this odorant. If you are unsure or unfamiliar with the smell of LP or natural gas, ask the gas supplier.
Other conditions, such as “odorant fade”, which causes the odorant to diminish in intensity, can also hide or camouage a gas leak. Always check with commercial
leak detector or soapy water.
• Gas detectors are recommended in LP and natural gas applications and their installation should be in accordance with the detector manufacturer’s recommendations and/or local laws, rules, regulations or customs.
• Water heaters utilizing LP gas are different from natural gas models. A natural gas water heater will not function safely on LP gas and vice versa.
• No attempt should ever be made to convert the water heater from natural gas
to LP gas. To avoid possible equipment damage, personal injury or re, do not
connect the water heater to a fuel type not in accordance with the unit data plate; propane for propane units and natural gas for natural gas units. These
units are not certied for any other fuel type.
LP appliances should not be installed· below grade (for example, in a basement) if such installation is prohibited by federal, state and/or local laws, rules, regulations or customs.
• Propane or LP gas must be used with great caution. It is heavier than air and will
collect rst in lower areas making it hard to detect at nose level.
• Before attempting to light the water heater, make sure to look and smell for gas
leaks. Use a soapy solution to check all gas ttings and connections. Bubbling at
a connection indicates a leak that must be corrected. When smelling to detect a
gas leak, be sure to sniff near the oor also.
• It is recommended that more than one method, such as soapy solution, gas detectors, etc., be used to detect leaks in gas applications.
Notice: If a gas leak is present or suspected:
DO NOT attempt to nd the cause yourself.
DO NOT try to light any appliance.
• DO NOT touch any electrical switch.
DO NOT use any phone in your building.
Leave the house immediately and make sure your family and pets leave also.
Leave the doors open for ventilation and contact the gas supplier, a qualied
service agency or the re department.
Stay away from the house (or building) until the service call has been made, the leak is corrected and a qualied agency has determined the area to be safe.
WARNING - Not intended or to be used for fuel types not listed on your tankless
water heater rating plate.
Page 8
6
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING
FOR INSTALLATIONS IN THE STATE OF CALIFORNIA
California Law requires that residential water heaters must be braced, anchored or strapped to resist falling or horizontal displacement due to earthquake motions. For residential water heaters up to 52 gallon capacity, a brochure with
generic earthquake bracing instructions can be obtained from: Ofce of the State
Architect, 400 P Street, Sacramento, CA 95814 or you may call 916-445-8100 or ask a water heater dealer.
However, applicable local codes shall govern installation. For residential water heaters of a capacity greater than 52 gallons or tankless style, consult the local building jurisdiction code for acceptable bracing procedures.
SAFETY PRECAUTIONS
Have the installer show you the location of the gas shut-off valve and how to shut it off if necessary. Turn off the manual shut-off valve if the water heater has been
subjected to overheating, re, ood, physical damage or if the gas supply fails to
shut off.
• Read this manual entirely before installing or operating the water heater.
• Use this appliance only for its intended purpose as described in this Use and Care Manual.
• Be sure your appliance is properly installed in accordance with local codes and the provided installation instructions.
Part of your water heater unless it is specically recommended in this manual.
All other servicing should be referred to a qualied technician.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY
SAVE THESE INSTRUCTIONS
WARNING!
For your safety, the information in this manual must be followed to minimize the
risk of re or explosion, electric shock, or to prevent property damage, personal
injury, or loss of life.
Page 9
7
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Indoor Location
Installation distances may vary by local code. It is the installer’s responsibility to verify
installation requirements.
Make sure before installation that the gas type you will use is the same type on the data plate.
The water heater unit should be installed by professionals. Improper installation may cause
failure or dangerous conditions such as gas leaking or explosion.
Water Heater cannot be installed in an UN-VENTED bathroom, bedroom, basement, living room, closet, outdoor, stairway or an exit area. If installed in an exit area, it must be at least 16.5 ft. or
more away from the exit.
Vent pipe should extend from the wall at least 2”. The terminal must be at least 1.64 ft. away
from obstruction, and must be well vented.
Vent pipe should slope 3° downward, to avoid condensing water and protect from rain entering.
Vent pipe should avoid direct, strong wind because the downdraft will cause malfunction.
The unit should be installed far from any blockage, and with plenty of enough space for
installation and maintenance. Adequate clearances for servicing must be provided.
The unit should not be installed in the same room with a gas stove .
When determining the oor clearance, a clearance of 6 inches must be maintained between the
vent pipe and combustible material. A side wall clearance of 6 inches and a top clearance of 12 inches must be maintained.
A maximum of 32 feet of vent pipe may be used provided there is only one 90° elbow in the system. If additional elbows are required: two elbows can be used with 27 feet, and three elbows can be used with 22 feet of vent pipe.
A 90° elbow is equivalent to 5 feet of straight pipe. A 45° elbow is equivalent to 2 feet 6 inches of straight pipe .
The vent pipe should be installed with a ame retardant wall thimble. Owner must refer to vent manufacturer’s instructions and specications.
The power socket connecting the water heater should be grounded properly with a GFCI circuit protector.
The water heater should not be located in an area where leakage of the heat exchanger or connections will result in damage to the area adjacent to it or to lower oors of the structure. When such areas cannot be avoided it is recommended that a suitable catch pan, adequately drained, must be installed under the water heater. The pan must not restrict combustion airow.
The water heater should be installed as close as practical to the vent termination to minimize vent length and the number of elbows required for venting.
A gas red water heater or any other appliance should not be installed in a space where liquids which give off ammable vapors are to be used or stored. Such liquids include gasoline, LP gas (butane or propane), paint or adhesives and their thinners, solvents or removers.
Installing the water heater
Page 10
8
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
The unit should be installed far from heat sources, ammable and dangerous materials. Because of natural air movement in a room or other enclosed space, ammable vapors can be carried some distance from where their liquids are being used or stored. The open ame of the water heater’s main burner can ignite these vapors causing an explosion or re which may result in severe burns, death or property damage.
Raising the water heater will reduce, BUT NOT eliminate the possibility of lighting the vapor of any ammable liquids which may be improperly stored or accidentally spilled .
If the water heater is installed in a garage, it should be installed so that the direct ignition system and main burner are no less than 18 inches above the garage oor.
Hot and cold water lines should be insulated to conserve water and energy.
The water heater must be located so it is not subject to physical damage, for example, by
moving vehicles, area ooding, etc.
The water heater should be installed with the proper venting materials and termination suitable for Category III venting. Failure to install and properly vent the water heater to the outdoors as outlined in the Venting Section of this manual can result in unsafe operation. Owner must refer to vent manufacturer’s instructions and specications.
For other than a direct vent appliance, the appliance must be located as close as practicable to a chimney or gas vent.
DO NOT install water heater where subject to vibrations or on the road use.
DO NOT install the water heater in Recreational Vehicles, Mobile Homes, Boats and other Watercraft.
DO NOT install the water heater near vents for heating or cooling. A minimum of 4 feet should
be maintained.
If the clearances stated on the Instruction/Warning Label, located on the front panel of the heater differ, install the water heater according to the clearances stated on the label.
Installing the water heater continued....
WARNING: Combustible construction refers to adjacent walls and ceilings and should not be confused with combustible or ammable products and materials. Combustible and/or ammable products and materials should never be stored in the vicinity of this or any gas appliance.
Page 11
9
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Proper operation of the water heater requires air for combustion and ventilation. Provisions for combustion and ventilation air must comply with referenced codes and standards.
Combustion and Ventilation Air
Installing the water heater continued....
A conned space is one having a volume of less than 50 cubic feet per 1,000
Btuh of the aggregate input of all appliances within that space.
The air must be supplied through two permanent openings of equal area. One is
to be located within 12” above the oor and the other is to be located within 12”
below the ceiling.
The minimum net free area of each opening must not be less than one square inch per 1,000 Btuh of the total input rating of all the appliances in the enclosure
(but not less than 100 square inches), if each opening communicates with other unconned areas inside the building.
Buildings of unusually tight construction shall have the combustion and ventilation air supplied from outdoors, or a freely ventilated attic or crawl space. If air is supplied from outdoors, directly or through vertical ducts, there
must be two openings located as specied above and each must have a minimum
net free area of not less than one square inch per 4,000 Btuh of the total input rating of all the appliances in the enclosure.
If horizontal ducts are used to communicate with the outdoors, each opening must have a minimum net free area of not less than one square inch per 2,000 Btuh of the total input rating of all the appliances in the
enclosure. If ducts are used, the minimum dimensions of rectangular air ducts shall not be less than 4”
Inspect Shipment
Inspect the water heater for possible damage. Check the markings on the rating plate of the water heater to be certain the type of gas supplied corresponds to the water heater requirements. Verify
all included parts are present (see below).
NOTICE: If the water heater is installed in an unconned space within a building of conventional frame, masonry or metal construction, inltration air is normally adequate for proper combustion and ventilation. If the water heater is installed in a conned space, provisions for combustion and ventilation air must be made.
NOTICE: If the duct openings which supply combustion and ventilation air are to be covered with a protective screen or grill, the net free area (openings in the material) of the covering material must be used in determining the size of the openings. Protective screening for the openings MUST NOT be smaller than 1/4” esh to prevent clogging by lint or other debris. .
Corrosive Atmospheres
The air in beauty shops, dry cleaning establishments, photo processing labs, and storage areas for liquid and powdered bleaches or swimming pool chemicals often contain such halogenated hydrocarbons.
An air supply containing halogenated hydrocarbons may be safe to breathe, but
when it passes through a gas ame corrosive
elements are released that will shorten the life of any gas burning appliance.
Propellants from common spray cans or gas leaks from A/ C and refrigeration equipment are
highly corrosive after passing through a ame.
The water heater warranty is voided when failure of the heater is due to operation in a corrosive atmosphere.
NOTICE: The water heater should not be installed near an any air supply containing halogenated hydrocarbons.
2
2
Page 12
10
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Water Supply Connections....
To conserve energy and to prevent freezing, insulate both cold and hot water supply lines. DO NOT cover the drain valves. Install a shutoff valve near the inlet of the water heater for service and draining purposes. Before connecting the water supply pipe to the water heater, open the shutoff valve ·and clean out sand, debris, air, caulking material, etc. inside the pipe. Connect to the water inlet, then check
water ow. Close the shutoff valve and clean the water lter.
If a water heater is installed in a closed water supply system, such as one having a backow preventer in the cold water supply line, means shall be provided to control thermal expansion. Contact the water supplier or local plumbing inspector on how to control this situation.
CAUTION: This water heater must only be used with the following water supply system conditions:
• With clean, potable water free of corrosive chemicals, sand, dirt, or other contaminates.
• With inlet water temperatures above 32°F, but not to exceed 90°F.
• Free of lime and scale deposits.
DO NOT reverse the hot and cold water connections. The water heater will not operate.
To ensure proper operation of the water heater, the following water pressure guidelines should be followed:
• Operation of the water heater requires the minimum water pressure of 14 psi and a minimum water
ow rate of 0.75 gpm.
Additional water pressure is required for long pipe runs and outlet tting(s) water pressure drops.
To maintain proper performance, ensure sufcient water supply pressure. The Required Water
Pressure = Min. Operating Water Pressure (14 psi) + Pipe Pressure Loss + Faucet and Shower Pressure Loss + Safety Margin (more than 5 psi).
To supply hot water to upper oors, additional water pressure (0.44 psi/ft) must be ensured.
• The measurement should be calculated by the distance between the water inlet of the water heater
(ground level) to the hot water faucet (upper oor level).
• Well water systems should be set at a range of 50-60 psi.
• When the water is supplied from a water supply tank, the height of the tank and the diameter of the pipes and their relation to water pressure, should be taken into consideration. Gravity water pressure is not recommended.
IMPORTANT: Do not apply heat to the HOT or COLD water connections. Any heat applied to the water supply ttings will permanently damage the internal components of the water heater.
NOTICE: If the water ow resistance of a shower head is too high, the burner in the water heater will
fail to ignite. Keep the shower head clean from debris that could cause additional pressure drop.
NOTICE: If using mixing valves on the outlet, choose one which prevents cold water pressure from
overcoming hot water line pressure.
DO NOT use pipes with smaller diameters than the water supply connection of the water heater.
Be sure to connect the water inlet and the hot water outlet as shown on the water heater. If reversed, the water heater will not function.
Installation of unions or exible copper connections are recommended on the HOT and COLD water
lines, so that the water heater may disconnect easily for servicing if necessary.
Plumbing should be carried out by a qualied plumber in accordance with local codes. Use approved
plumbing materials and tools only.
Install a Check Valve between the water heater and the water shutoff valve. (See illustration below).
Page 13
11
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Water Supply Connections Continued....
In regards to the HOT WATER OUTLET:
Connections between the water heater and point(s) of use should be as short and direct as possible.
• DO NOT use lead or non-approved plastic pipe.
• To conserve energy and minimize heat loss, insulation of hot water piping is recommended.
NOTICE: The ow rate of hot water may vary when more than two faucets (appliances, xtures, etc.) are being used simultaneously. NOTICE: The pipes MUST be completely drainable. If the hot water faucets are located at a point higher than the water heater, place a drain valve at the lowest point (see diagram to the left).
A new pressure relief valve, complying with the Standard for relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, must be installed at the hot water outlet connection of the water heater at the time of installation. Local codes shall govern the installation of relief valves.
For safe operation of the water heater, be sure that:
• The pressure rating of the relief valve must not exceed 150 psi, the maximum working pressure of the water heater as marked on the rating plate.
• The BTUH rating of the relief valve must equal or exceed the BTUH input of the water heater as marked on its rating plate.
• No valve of any type should be installed between the relief valve and the water heater.
• Discharge from the relief valve should be piped to a suitable drain to eliminate potential water damage. Piping used should be of a type approved for the distribution of hot water.
• Hot and cold water lines should be insulated up to the water heater.
• The discharge line must be NO SMALLER than the outlet of the valve and must pitch downward to allow
complete drainage (by gravity) of the relief valve and discharge line.
• The end of the discharge line should not be threaded or concealed and should be protected from freezing. No valve of any type, restriction or reducer coupling should be installed in discharge line.
NOTICE: The diagram below illustrates a pressure only relief valve. If local codes require a combination temperature and pressure relief valve be installed, an extension piece may be needed.
Relief Valve
NOTICE: Local codes govern the installation of relief
valves. If local codes require that a temperature and pressure relief valve should be installed the manufacturer recommends a type 40XL Watts T&P relief valve or an equivalent model be used.
NOTICE: Manual operation of relief valves should be
performed at least once a year. Turn off the electrical power and gas shutoff valve. Lift and release lever on the relief valve and check the manual operation of the relief valve. You should take precaution to avoid contact with the hot water coming out of the relief valve and to prevent water damage.
NOTICE: If the relief valve on the system discharges
periodically, this may be due to thermal expansion in a closed water supply system. Contact the water supplier or local plumbing inspector on how to correct this situation. Do not plug the relief valve.
Front cover
Motor fan
Temperature controller
Heat exchanger
Fixing board
Water flow sensor
Hot water temp. sensor
Fixing board
Back cover
Motor fan
Burner assembly
Wind Switch
Heat exchanger
Water flow sensor
Water inlet pipe
Hot temperature sensor
Gas inlet pipe
Gas flute
Temp controller
Computer board
Gas valve
Page 14
12
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
The supplied Manual Gas Appliance Shutoff Valve must be installed at the gas connection of the water heater at the time of
installation (see diagram to
the left). The branch gas supply line to the water heater should be clean black steel pipe or other approved gas piping material. A ground joint union or ANSI
design certied semi-rigid or exible gas appliance
connector should be installed in the gas line close to the water heater. The National Fuel Gas
Code (NFGC) mandates a
manual gas shut-off valve:
See (NFGC) for complete
instructions.
A sediment trap should be installed at the bottom of the gas line. The inlet gas pressure to the water heater must not exceed 10.5“ w.c. for natural
or 14” w.c. for LP gas. For purposes of
input adjustment, the minimum inlet gas
pressure (with main burner on) is shown on
the water heater rating plate. If high or low gas pressures are present, contact your gas supplier for correction
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures
in excess of ½ psi (3.5 kPa). The appliance
must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5
kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than ½ psi (3.5 kPa).
WARNING:
Never use an open ame to test for gas leaks, as property damage, personal injury, or
death could result.
Gas Supply
WARNING: Do not attempt to convert this water heater for use with a different type of gas other than the type shown on the rating plate. Such conversion could result in hazardous operating conditions. Please have a professional connect the gas pipe.
The water heater and its gas connections must be leak tested at normal operating pressures before it is placed in operation.
Turn on the gas shut-off valve(s) to the water heater.
Use a commercial leak detector or soapy water solution to test for leaks
at all connections and ttings. Bubbles indicate a gas leak that must be
corrected.
All connections should also be leak tested after the water heater is placed in operation.
DO NOT use excessive force (over 31.5 ft lbs.) in
tightening the pipe, particularly if pipe compound is used, as the unit may be damaged.
Compound used on the threaded joints of the gas piping must be of the type resistant to the action of LP gas. Use compound sparingly and use on male threads only.
Pressure Testing the Gas Supply System
WARNING: Install a gas pressure regulator, in the gas supply line, which does not exceed the maximum supply pressure. DO NOT use an industrial type gas regulator.
The water heater must be isolated from the gas piping system by closing the manual gas shut-off valve during any pressure testing of the gas supply piping at pressures equal to or
less than 1/2 psi (14’w.c.) .
High Altitude
Ratings of gas appliances are based on sea level operation and need not be changed for installations at elevations up to 2,000 feet. Unit not recommended for elevations in excess of 2,000 feet
Leak Testing
Page 15
13
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
NOTICE: The National Fuel Gas Code (NFGC) mandates a manual gas shut- off valve: See (NFGC) for complete instructions. Local codes or plumbing authority requirements may vary from the instructions or diagrams provided and take precedent over these instructions.
Installing the water heater.
Typical Installation ( Some Items May Not Apply)
(Not Supplied)
Page 16
14
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Indoor unit must be installed with CAT 3 vent pipe in accordance with vent supplier/
Manufacturer in accordance with local code.
A. BACK INSTALLATION
1. Insert the vent pipe through the installation holes in the wall with the terminal sticking out.
2. Connect the elbow to the vent pipe and water heater, moving straight backwards until the expansion screws go into the holes
of the water heater. Screw the nuts tight (pay
attention to the direction of the elbow).
B. SIDE INSTALLATION:
1. Aim the holes in the water heater onto the expansion screws, hang it up and screw the nuts tightly.
2. Put the vent pipe through the holes in the wall, and connect the elbow with the water heater and vent pipe.
C. VERTICAL INSTALLATION
Please refer to local installation professional or venting manufacturer:
The installation hole in the wall needs to be
sealed by re-retardant material or wall
thimble, making sure the water heater is tight and will not come off.
Mounting the Water Heater
Make sure the location of the appliance allows for easy access and operation.
In case of dry wall or concrete wall use dry wall anchors or lag bolts.
The water heater requires 120VAC/ 60Hz. Have a receptacle with ground terminal near the water heater. The length of the power supply cord is 5 feet.
Drill the holes as per the sizes in the gure to the left, put 2
expansion screws into the top holes, and 2 rubber screws into the bottom holes.
Hang up the water heater unit, tighten the expansion screws, and put 2 wood thread screws into the bottom holes.
CAUTION: Reinforcement of the wall is
required in case the wall is not strong enough to hold the appliance.
Page 17
15
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Venting
The installation of venting must comply with national codes, local codes, and the vent manufacturer’s instructions.
The water heater must be vented to the outdoors as described in these instructions. DO NOT connect this water heater to an existing Vent or Chimney, it must be vented separately from all other appliances.
All vent components (adapters,
pipe, elbows, terminals, etc.) should
be UL 1738 Certied Stainless Steel Venting Material (e.g. AL29-4C).
The specied vent termination
must be used. The termination should be a 90° elbow type with
screen. (Refer to page 19).
Use a vent pipe with an anti­disconnection structure.
The use of a High Temperature
Silicone (500’ F) may be required
to seal vent connections. To prevent accidental gas exhaust
leakage, apply a 1/4” wide bead approximately 1/4” from the end
and another bead against the joint side of the stop bead.
Follow vent manufacturer’s installation instructions.
The unit can be vented either horizontally or vertically.
Vent pipe runs must be adequately supported along both horizontal and vertical runs.
The maximum recommended unsupported span should be no
more than ve (5) feet. Support
isolation hanging bands should be used. DO NOT use wire. (See diagram below).
DANGER: Failure to
install the vent adapter and properly vent the
water heater to the outdoors as outlined in
the Venting section of
this manual will result
in unsafe operation
of the water heater
causing death, serious injury, explosion, or re. To avoid the risk of re, explosion,or asphyxiation from carbon monoxide, NEVER operate the
water heater unless
it is properly vented and has adequate air supply for proper operation as outlined in the Venting section of
this manual.
WARNING: Use
approved Category III Stainless Steel vent
material only. No
other vent material is permitted.
Owner must refer to
vent manufacturer’s
instructions and
specications. Z-Flex
information can
be found at www. novaex.com, see page 19 for additional links.
WARNING:
Refer to pages 17-
18 for clearances to
combustible material.
Installing the water heater
Venting Through Closed Spaces
If the vent piping passes through a closed space, wrap the vent pipe with inammable insulation material that is at least 3/4” thick. DO NOT let the insulation material make contact with ammable materials. A minimum clearance of 6” between the vent pipe and ceiling should be maintained. Follow local codes.
For maintenance and inspection purposes, the following holes are required to be made:
• Two (2) inspection openings that allow access to venting. One
(1) of these openings should be close to where the vent pipe
enters the ceiling. The other opening should be near the vent termination.
• A ventilation hole with a 16 sq. in. opening should be made at least every 10 feet.
NOTICE: Vent pipes must be completely insulated with
inammable material when installed in alcoves, closets, and
garages and must not touch any ammable material.
Page 18
16
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Installing the water heater, Continued....
Venting Lengths
MAXIMUM VENT LENGTH
The system will not operate if there is excessive restriction (pressure drop) in the venting system. A maximum of 32 feet of vent pipe may be used provided there is only one 90° elbow in the system. If additional elbows are required: two elbows can be used with 27 feet, and three elbows can be used with 22 feet of vent pipe.
A 90° elbow is equivalent to 5 feet of straight pipe. A 45° elbow is equivalent to 2 feet 6 inches of straight pipe .
The termination elbow does not count as an elbow when determining total vent lengths.
The vent must be installed with a slight downward slope of 1/ 4” per foot of horizontal run toward the vent terminal (see diagram below). This ensures that any condensate formed during operation of the unit is evacuated from the appliance
A 1/4” per foot upward slope is acceptable when it is not possible to vent with a downward slope, however, a approved Category III Stainless Steel condensate trap MUST be installed at the beginning of the horizontal run (See page 20 “Typical Horizontal Termination w/ 1/4” per foot UPWARD Slope” or page 14, “Standard Vertical Vent Termination” for examples).
Number of
90° elbows
(bends)
Maximum
Length of
Straight Pipe
1
2
3
32’
27’
22’
One (1) 90° Elbow is
Equivalent to 5 Feet of
Straight Pipe
MINIMUM VENT LENGTH
The venting may be as short as 12”,
provided one vent termination is installed to the outdoors through a sidewall, one 90°elbow is included in the installation, and the wall thimble is installed.
NOTICE: Make sure that the seam
of the vent pipe in horizontal runs is toward the top of the installation
(see illustration to the left)
Draining the Condensate
In certain conditions, installations in unconditioned space or having long horizontal or vertical runs may accumulate condensate.
Condensate is known to be acidic; refer to local, state (provincial) or federal codes for proper
handling methods.
In order to prevent condensate from draining back into the water heater, we recommend a condensate trap and drain to be installed in a horizontal vent section as close as practical to the water heater vent connection.
Not following proper condensate procedures will void warranty.
12 in. minimum
Page 19
17
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Installing the water heater, Continued....
US Installations1 Canadian Installations2
A = Clearance above grade,
veranda, porch, deck, or balcony
12 in (30 cm) 12 in (30 cm)
B = Clearance to window or
door that may be opened
4 ft (1.2 m) below or to side of opening; 1 ft (300 mm) above opening
6 in (15 cm) for appliances ≤ 10,000 Btuh (3 kW), 12 in (30 cm) for appliances > 10,000 Btuh (3 kW) and ≤ 100,000 Btuh (30 kW), 36 in (91 cm) for appliance > 100,000 Btuh (30 kW)
C = Clearance to permanently
closed window
*
D = Vertical clearance to
ventilated soft located above the terminal within a horizontal distance of 2 feet (61 cm) from the
center line of the terminal
*
E = Clearance to unventilated
soft
*
Page 20
18
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
F = Clearance to outside corner *
G = Clearance to inside corner *
H = Clearance to each side of
center line extended above meter /regulator assembly
* 3 ft (91 cm) within a height 15
ft above the meter/regulator assembly
I = Clearance to service
regulator vent outlet
* 3 ft (91 cm)
J = Clearance to non-
mechanical air supply inlet to building or the combustion air inlet to any other appliance
4 ft (1.2 m) below or to side of opening; 1 ft (300 mm) above opening
6 in (15 cm) for appliances ≤ 10,000 Btuh (3 kW), 12 in (30 cm) for appliances > 10,000 Btuh (3kW) and ≤ 100,000 Btuh (30 kW), 36 in (91 cm) for appliances > 100,000 Btuh (30 kW)
K = Clearance to a mechanical
air supply inlet
3 ft (91 cm) above if within 10 ft (3 m) horizontally
6 feet (1.83 m)
L = Clearance above paved
sidewalk or paved driveway located on public property
* 7 ft (2.13 m)
M = Clearance under veranda,
porch, deck or balcony
* 12 in (30)
* For clearances not specied in ANSI Z223.1 / NFPA 54 or CSA-B149.1, one of the following shall be indicated:
A) A minimum clearance value determined by testing in accordance with Clause 5.20, or;
B) A reference to the following footnote:
“Clearance in accordance with local installation codes and the requirements of the gas supplier.”
• A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
• Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath
the oor.
Notes:
1. In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code
2. In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Cod
Page 21
19
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Installing the water heater, Continued....
WARNING: Use UL approved Category III vent material only. No other vent material is permitted. Owner must refer to vent manufacturer’s instructions and specications. Z-Flex information can be found at www.novaex.com, refer to page 19 for additional links.
CAUTION: Follow the vent manufacturers installation instructions as design might vary from manufacturer to
manufacturer.
12 in.
minimum
12 in.
minimum
Page 22
20
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
HARDWIRING THE ELECTRICAL CONNECTIONS:
• Wiring should be carried out by a qualied
electrician in accordance with local codes.
• The water heater requires 120 VAC/60Hz and should be properly grounded.
• DO NOT connect grounding wire to water pipes, gas pipes, telephone cables, lightning conductor circuits and to grounding circuit of other equipment that carry a ground-fault interrupter.
• An ON/OFF switch must be provided and installed for the incoming 120VAC power.
• Wire the water heater exactly as shown below. A wiring diagram is also found inside of the cover panel.
• A green screw is provided in the junction box for grounding connection.
• Connect the live wire to black leg wire and the neutral wire to the white neutral wire.
Electrical Connection
POWER CORD:
• The electric power supply requirement for
this water heater is 120 VAC/60HZ, 2 Amps.
• The water heater comes with a three (3) pin
power supply cord. Use only a power outlet with a ground terminal.
• The installation of an electric leakage
breaker is recommended. (GFCI)
• Keep any excess of the power supply cord on the outside of the water heater.
• If local codes require hardwiring, see instructions for “Hardwiring the Electrical
Connections”.
WARNING :Field wiring connections and electrical grounding must comply with local codes.
WARNING: Shock hazard line voltage is present. Before servicing the water heater, turn off the electrical power to the water heater at the main disconnect or circuit breaker. Failure to do so could result in severe personal injury or death.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify correct operation after servicing.
Electric Wiring Diagram
Page 23
21
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Insulation blankets, available to the general public, for external use on gas water heaters are not necessary. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. This water heater does not store water making an insulation blanket unnecessary.
The manufacturer’s warranty does not cover any damage or defect caused by installation, attachment or use of any type of energy saving
or other unapproved devices
(other than those authorized by
the manufacturer) into, onto or in conjunction with the water heater.
The use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property.
The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices.
WARNING: If
local codes require external application of insulation blanket kits the manufacturer’s
instructions included
with the kit must be
carefully followed.
Insulation Blankets
Hot and Cold Pipe
Insulation Installation
For increased energy efciency,
use pipe insulation. Please install the insulation, according to the illustrations above, making sure to insulate all the way to the top. Do not
cover any drain or pressure valve(s).
Pipe Installation
Inlet Pipe and Outlet Pipe Installation
Use pressure resistant pipe to connect the inlet and outlet water pipes of the water heater and the local water pipe
(Make sure to place the rubber ring).Before connecting the inlet water pipe, ush the inside of the pipe. use sealant to
prevent leaks
NOTICE: The hot and cold pipes should be insulated as shown help to provide additional freeze protection
During Installation of this water heater
Do’s
DO check inlet gas pressure to ensure that it is within the range specied on the rating plate.
DO provide adequate air for combustion and ventilation as discussed in the Use & Care Manual and the
National Gas Code (CAN/CGA B 149 in Canada).
DO maintain proper clearances to combustibles as specied by applicable code.
DO ensure that the ue terminal location complies with the guidelines found in the Use & Care Manual and
National Fuel Gas Code (CAN/CGA B 149 in Canada).
Dont’s
DON’T block or restrict Air Intake Opening located on the back side of the water heater.
DON’T remove the front cover unless absolutely necessary. This should only be done after being examined by a
qualied service technician.
DON’T install this product where standing water may occur.
Page 24
22
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Installing the water heater
Installation Check List
A. Water Heater Location
Installed INDOORS.
• Close to area of mostly used outlet.
• Protected from freezing temperatures.
• Proper clearance from combustible surfaces observed.
Sufcient fresh air supply for proper operation of water heater.
Air supply free of corrosive elements and ammable vapors.
• Provisions made to protect area from water damage.
Sufcient room to service heater.
• Combustible materials, such as clothing, cleaning materials, rags, etc. clear of the heater and vent piping.
• Water heater is properly attached to the wall.
B. Water Supply
Water supply has sufcient pressure.
• Air purged from water heater and piping.
• Water connections tight and free of leaks
Water lter is clean and in place.
• Materials used are as instructed in this manual.
• Water pipes are insulated.
C. Gas Supply
• Gas type matches rating plate.
Gas supply pressure is sufcient for the water heater.
• Gas line equipped with shut-off valve, union and sediment trap.
• Approved pipe joint compound used.
Commercial leak detector or soap and water solution used to check all connections and ttings for possible gas leak.
Gas Company inspected installation (if required).
D. Relief Valve
• Pressure Relief Valve properly installed and discharge line run to open drain
• Discharge line protected from freezing.
E . Electrical Wiring
• Voltage matches rating plate.
• Water heater is properly grounded .
• Wiring meets all local codes.
• GFCI Protection where required.
Page 25
23
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Lighting the Water Heater
Before operating this water heater, be sure to read and follow the instructions on the label pictured below and all other labels on the water heater, as well as the warnings printed in this manual. Failure to do so can result in unsafe operation of the water heater resulting in property damage, personal injury, or death. Should you have any problems reading or following the instructions in this manual. STOP, and get help from a
qualied person.
WARNING: If you do not follow these instructions exactly, a re or explosion may result causing property damage, personal injury or loss of life.
FOR YOUR SAFETY BEFORE USING THE WATER HEATER
OPERATING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the
oor because some gas is heavier than air and will settle on the oor. Test all connections with a
commercial leak detector or soapy water.
WHAT TO DO IF YOU SMELL GAS
DO NOT try to light any appliance • DO NOT touch any electric switch; DO NOT use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions. • If you cannot reach your gas supplier or re department. • DO NOT return to your home until authorized by the gas supplier or re department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not
push in or turn by hand, don’t try to repair it, call a qualied service technician. Force or attempted repair may result in a re or explosion.
D. DO NOT use this appliance if any part has been under water. Immediately call a qualied service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
1. STOP! Read the safety information above on this label.
2. Turn off all electric power to the appliance.
3. Set the thermostat to lowest setting.
4. DO NOT attempt to light the burner by hand.
5. Turn the Gas Shut-off Valve located on the outside of the unit clockwise to the “OFF” position.
6. Turn off all electrical power to the appliance
7. Wait ve (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” in the safety
information above on this label. If you don’t smell gas, go to the next step.
8. Turn the Gas Shutoff Valve located on outside of the unit counterclockwise to the “ON” position.
9. Turn on all electric power to the appliance.
10. Set thermostat to desired setting.
11. If the appliance will not operate, follow the instructions “To Turn Off Gas To Appliance” and call
your service technician or gas supplier.
1. Turn off all electric power to the appliance if service is to be performed.
2. Turn the Gas Shut-off Valve located on the outside of the unit clockwise to the “OFF” position.
Page 26
24
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Operating the Water Heater.
Turning on the Water Heater
1. Make sure the gas type you will use is same as the type on the data plate.
2. Turn on the main gas valve, plug in the power cord (be sure the socket is well grounded), and press the “ON/OFF”button on the control panel. Set temperature to 120° F.
3. when you need to set the temperature up to 122F, press the children lock for 3 seconds and the light will be off, then you can set higher temperature.
4. Turn on the faucet, and the fan will begin working. You will hear the ignition sound after a few seconds. The burner will ignite, and hot water will come out. If the burner is not ignited successfully, the ignition sound will last a few seconds. If the burner still fails to ignite, turn off the faucet and wait for 10-20 seconds, and repeat the above procedures.
For rst use and/or if the water heater has not been used for a considerable period of time, the
repeat of the above procedures may be required, due to accumulated air inside the gas pipe.
Safety Precautions
If there is any difculty in understanding or following the Operating Instructions or the Care and Cleaning section, it is recommended that a qualied person or serviceman perform the work.
• DO NOT store or use gasoline or other
ammable vapors and liquids, such as
adhesives or paint thinner, in vicinity of this
or any other appliance. If such ammables
must be used, open doors and windows for ventilation, and all gas burning appliances in the vicinity should be shut off including their pilot lights, to avoid vapors lighting.
NOTICE: Flammable vapors can be drawn by air currents from surrounding areas to the
water heater
• DO turn off manual gas shut-off valve if water heater has been subjected to over
heating, re, ood, physical damage or if the
gas supply fails to shut off.
• DO NOT turn on water heater unless water and gas supplies are fully opened.
• DO NOT turn on water heater if cold water supply shut-off valve is closed.
• DO NOT allow combustible materials such as newspaper, rags or mops to accumulate near water heater.
Page 27
25
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Set Temperature Memory:
• This water heater contains an electronically controlled thermostat. From the factory, the temperature range is between 90°F and 140°F.
• The remote control is factory preset to 110°F.
• To turn the remote control ON or OFF, press the POWER button for more than 3 seconds.
• To adjust the temperature to a required setting,
in“priority” mode, press the UP or DOWN temperature
button. Press and hold UP or DOWN to raise or lower the temperature continuously.
• When the unit is in use, the set temperature can increase to 122°F, but there is no limit to temperature decrease. To increase the temperature more than
122°F, the water will need to be shut off rst.
NOTICE: If inlet water temperature is high, and set temperature is low, the actual temperature might be higher than the set temperature, and vice versa..
DANGER: There is a hot water
scald potential if the temperature is set too high. Households with small children, disabled, or elderly persons may require a 120°F. or lower temperature setting to prevent
contact with HOT water.
Output temperature of water is regulated by setting the temperature on the front of the remote control.
Safety factors should be considered when selecting the water temperature setting of the water heater’s remote control. The remote control was set at 110°F before the water heater was shipped from the factory. This is the recommended starting point.
Water temperatures above 120°F can cause severe burns or death from scalding. The thermostat is adjusted to its lowest temperature position when shipped from the factory.
Be sure to read and follow the warnings outlined in this manual and on the label located on the water heater. Mixing valves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines.
Procedures for adjusting the thermostat for energy efcient operation at the minimum water temperature setting consistent with the consumer’s needs.
Contact a licensed plumber or the local plumbing authority for further information. See page 4 for
details.
Water Temperature Setting
Water Temperature
120°F 125°F 130°F 135°F 140°F 145°F 150°F 155°F
Time To Produce a Serious Burn
More than 5 minutes
1 1/2to 2 minutes
About 30 seconds
About 10 seconds Less than 5 seconds Less than 3 seconds About 1 1/2 seconds
About 1 second
Table courtesy of Shriners Burn Institute
• The display will read the set temperature if the water
heater is not in use or there is no water ow. If the water heater is in use or has water ow, the display
will read the actual temperature. To view the set temperature in this condition, press UP or DOWN and
the set temperature will ash for 3 seconds.
• The hottest temperature water will be at the hot water faucet closest to the water heater
• Always remember to test the water temperature with your hand before use and remember that hotter water increases the risk of scald injury.
• Always supervise young children or others who are incapacitated.
If the water heater has been subjected to re, ood or physical damage, turn off the manual gas shut-off
valve(s), and do not operate the water heater again until it has been checked by qualied personnel.
WARNING: Should overheating occur or the gas supply fail to shut off, turn off the manual gas
control valve to the appliance.
Page 28
26
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Properly maintained, your water heater will provide years of dependable trouble-free service. It is recommended that a periodic inspection of the burner, relief
valve, water lter and venting
system should be made by service
personnel qualied in gas appliance
repair.
It is suggested that a routine preventive maintenance program be established and followed by the user.
At least once a year, lift and release the lever handle on the pressure relief valve, located in the hot outlet piping of the water heater, to make certain the valve operates freely.
Allow several gallons to ush
through the discharge line to an open drain.
Rapid closing of faucets or solenoid valves in automatic water using appliances can cause a banging noise heard in a water pipe. Strategically located risers in the water pipe system or water hammer arresting devices can be used to minimize the problem.
Inspect the area around the water heater to ensure a safe operating environment. Keep appliance area clear and free from combustible materials, gasoline,
and other ammable vapors
and liquids. Ensure the unit has not been damaged. If damage or denting is present, contact a service personnel to verify proper operation.
Check for any abnormal sounds during normal operation of the water heater.
All piping should be checked for gas and/or water leaks. Refer to page 12 of this manual for instructions on leak testing.
The air intake and cold water supply
lters should be cleaned monthly. Refer to the “Housekeeping” section
for further information.
DO NOT operate the water heater
if you feel something is wrong with the unit.
DO NOT allow children to operate
or otherwise handle the unit.
DANGER: Before
manually operating the relief valve, make
certain no one will
be exposed to the danger of the hot water released by the valve. The water may be hot enough to create a scald hazard. The water should be released into a suitable drain to prevent injury or property damage.
DANGER: Hotter water increases the
potential for Hot Water
Scalds.
DANGER: Failure
to perform the
recommended
Routine Preventative
Maintenance can harm
the proper operation
of this water heater, which can cause
carbon monoxide dangers, excessive hot water temperatures and other potentially hazardous conditions.
Care and cleaning of the water heater.
Routine Preventative Maintenance
NOTICE: If the pressure relief valve on the hot water heater discharges periodically, this may be due to a problem in the water system. Contact the water supplier or your plumbing contractor on how to correct this. DO NOT plug the relief valve outlet.
NOTICE: After inspection, maintenance, and/ or cleaning, ensure proper operation by turning on a hot
water faucet.
Before performing any Housekeeping tasks to this water heater, be sure to turn the unit off and disconnect the power supply.
Vacuum around the water heater for dust, dirt and lint on a regular basis. Clean the water heater and remote control by using a damp soft cloth with a few drops of mild detergent and gently wiping the surfaces of the unit. Wipe any remaining moisture with a dry soft cloth.
To ensure sufcient ventilation and combustion air supply, proper clearances must be maintained. The water lters should be cleaned on a monthly basis.
DANGER: Shock Hazard. Make sure the electrical power to the water heater is off to avoid potential serious
injury or damage to components.
DANGER: Combustible materials, such as clothing, cleaning materials, or ammable liquids, etc., must not
be placed against or next to the water heater.
Housekeeping
Page 29
27
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
CLEANING THE WATER HEATER AND REMOTE CONTROL(S):
• Make sure the unit is OFF and the electrical power supply has been disconnected.
DO NOT scrub the appliance with a brush.
• Use only mild soapy water, other cleaners may damage the surface of the water heater.
DO NOT remove any label including the rating plate while cleaning or servicing.
DO NOT splash water on the remote controls when cleaning.
NOTICE: DO NOT block or obstruct the air intake opening located at the lower left corner of the water heater. A minimum of 12” is required between this combustion air inlet opening and any obstruction.
Venting System Inspection
The venting system should be inspected annually to ensure all of the vent sections are secure and airtight.
It is recommended that qualied service personnel familiar with Category III venting inspect the venting system.
Check vent connection joint sections with a solution of soapy water to assure airtightness while the unit is operating. Bubbles around a joint connection indicates a seal leak. Refer to page 14 for vent sealing instructions.
DO NOT operate the unit if vent system shows signs of leaking exhaust.
Check to make sure that the Air Intake and the vent terminal have not been blocked or contain debris.
Vacation and Extended Shut-Down
If the water heater is to remain idle for an extended period of time, the power and water to the appliance should be turned off.
The water heater and piping should be drained if they might be subjected to freezing temperatures.
After a long shut-down period, the water heater’s operation and controls should be checked by qualied service
personnel.
HOW TO CLEAN THE WATER FILTER:
1. Make sure the unit is OFF and the electrical power supply has been disconnected.
2. Turn the water supply OFF to the heater.
3. Unscrew the water lter, and slide the lter out.
4. DO NOT tap the lter as it may deform and/or damage the lter.
5. To remove severe dust, use a soft brush and wash with running water.
6. Return the lter to the water heater and screw in the lter.
7. Turn the electrical power supply and cold water supply ON to the water heater
Housekeeping continued...
Not Equipped with Anti-Freezing Protection Draining Procedure
When the temperature falls below 32°F, water in your plumbing system or water heater can turn to ice and then expand causing damage to the water heater. This damage is not covered under your manufacturer’s warranty. If these conditions are anticipated, please drain the water heater as follows to help but not guarantee from freezing:
1. Shut off the main gas valve and power
2. Shut off the inlet water valve
3. Open all faucets
4. Take off the drain valve, and allow water to drain for 3 minutes or until the unit is empty.
5. Making sure all water is out, replace the drain valve, and shut off the faucets.
Page 30
28
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Care and cleaning of the water heater.
Draining the Water Heater
Below are instructions for draining water out of the water heater.
1. Turn off the switch on the remote control.
2. Close the gas shut-off valve(s).
3. Close the water shut-off valve.
4. Turn the on/ off switch to the OFF position and disconnect breaker at least 10 seconds after step #1.
5. Open drain valve.
6. Open all hot water faucets. Before proceeding to the next step, make sure that COLD water is coming out of all
hot water faucets.
7. To put the water heater back into operation after draining, follow the steps below.
8. Reinstall the water lter. Close the hot water outlet drain valve.
9. Open the water shut-off valve and close again after making sure that water comes out from hot water faucets.
(This step is to remove air from the water lines.)
10. Reconnect the breaker and turn the on/off switch to the ON position, fully open the gas shut-off valve and the
water shut-off valve.
NOTICE: The water heater may not operate unless the above procedure is followed correctly.
WARNING: Failure to follow these instructions while
draining the water
heater can cause
serious damage to the
water heater as well
as personal injury including scalding.
Page 31
29
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Before You Call For Service
Troubleshooting Tips
Save time and money! Review the charts on the following pages rst and you
may not need to call for service.
This water heater incorporates a variety of shut off devices that prevents the operation of the water heater down if undesirable combustion conditions occur.
Such as the presence of a blockage of the combustion air vent insufcient gas
or pressure which can impact the safe operation of the water heater. Please
contact a Qualied Service Technician if this occurs.
Problem
Possible Cause
What To Do
Not enough or no
hot water
Water shutoff valve is not fully opened.
Check shutoff valve and open fully.
Hot water faucet is not fully opened
Open hot water faucet completely.
(The main burner goes off when incoming
water volume is inadequate.
Water piping is frozen Allow piping to thaw.
No electricity or water supply is cut off.
Check that proper power is being supplied and/or water supply is adequate.
Unit is not “ON”.
Turn the unit “ON” by the button on the
remote control.
The temperature may be set too low
Increase the temperature setting.
Mixing Valve malfunction
(if applicable).
Check and replace if necessary.
Error code displayed on remote control panel
See instructions for Error Code and if required, contact a dealer for service.
Water not hot
enough
The temperature may be set too low.
Increase the temperature setting.
The gas valve is not fully opened.
Check and open the gas valve fully.
Water too hot
The temperature is set too high
Decrease the temperature setting.
Water shutoff valve is not fully opened.
Check shutoff valve and open fully.
Small amount of water has been heated.
Allow more water to ow.
Water lter is clogged Clean the lter with a tooth brush.
Fan continues to
rotate after hot
water faucet is
closed.
This function is to purge unburned gas 10-15 seconds.
Normal operation. There is no need to call for service. Check for error code.
Page 32
30
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Error
Code
Error Description Possible Cause What To Do
E0
Hot water sensor failure
Junction port loose, Short circuit
Call for Service
E1
Ignition system failure
The gas valve is not opened or fully opened, Water shut-off valve is not open, Junction port loose
Check and open gas fully, Check and open water valve, Call for Service
E2
There is ame when no
water coming in
Electric circuit problem Call for Service
E3
Over-heating protection
Dry Combustion, Problem of over heating controller
Call for Service
E5
Pressure Switch
Motor problem, Voltage of power supply is too low
Call for Service
E6
Over-heating
Gas pressure is too high, Water shutoff valve is not fully opened, The temperature is set too low
Check shut-off valve and open fully, Increase temperature setting
E7
Solenoid valve
Open circuit of the valve, short circuit of the valve, none of the above
Connect the valve, replace the valve, replace the computer board
If the error code remains shown:
• Close the hot water faucet and turn off the switch on the remote control.
• Take the proper action shown below and attempt operation of the appliance again.
• If the error code is still shown:
• Turn off the hot water faucet and turn off the switch on the remote control.
• Take note of the error code displayed and call the customer service assistance number
in the “If You Need Service”
When an error code is displayed:
• Close the hot water faucet, turn off the switch on the remote control.
• Wait for about 5 minutes before turning the switch on again.
• Open the hot water faucet.
NOTICE: If an error code other than those listed
below is displayed, immediately turn off the hot
water faucet, take note of the error code, turn off the switch on the remote control and call the
customer assistance number.
Error Code Guide
CAUTION: For your safety DO NOT attempt repair of gas piping, remote control, burners, vent connectors or other safety devices. Refer repairs to qualied service personnel.
CAUTION: Make certain power to water heater is “OFF” before removing protective cover
FOR ANY REASON.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. VERIFY PROPER OPERATION AFTER
SERVICING.
Page 33
31
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Display screen
Front cover
Motor fan
Temperature controller
Heat exchanger
Fixing board
Seal ring
Water flow sensor
Burner assemblu
Ignition pin
Proportion Valve
Flame sensor
Flame sensor board
Solenoid valve
Gas inlet pipe
Back cover
Power cord
Gas flute
Water inlet pipe
Computer board
Wind switch
Clip
Hot water temp. sensor
Replacement Parts
For models using natural or LP gas.
Instructions for placing a parts order
Address parts orders to the distributor or store from where the water heater was
purchased.
All parts orders should include:
• The model and serial number of the water heater from the rating plate.
• Specify type of gas (natural or LP) as marked on the rating plate.
• Part description (as noted below) and number of parts desired.
WARNING: For your safety,
DO NOT attempt to disassemble this
unit for any reason
CAUTION: For your safety, DO NOT attempt repair of electrical wiring, gas piping, burners, or other safety devices. Refer repairs to qualied service personnel.
Page 34
32
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Eccotemp Systems ,LLC
Limited Warranty Information
i12 LP & NG
Eccotemp hereby warrants this product to be free of material defects in materials and workmanship when installed and operated according to Eccotemp’s installation and operating instructions. This Limited Warranty extends to the original purchaser and subsequent owners, but only while the product remains as the site of the original installation. This Limited Warranty terminates if moved or reinstalled at a new location. There are no warranties, express or implied made or given other than contained in this Limited Warranty. No agent, employee or representative of Eccotemp has any authority to bind Eccotemp to any representation or warranty concerning the Product not contained in this Limited Warranty. Eccotemp reserves the right and authority to change, modify or alter this warranty at any given time.
Except as expressly set forth herein, THERE ARE NO REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, AS TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ANY GOODS SOLD HEREUNDER. BUYER’S EXCLUSIVE REMEDY IS LIMITED TO REPAIR OR REPLACEMENT OF THE GOODS SOLD, AT ECCOTEMP’S DISCRETION. ECCOTEMP SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Limited Warranty Period
This Warranty is extended by Eccotemp Systems to the Owner. This warranty takes effect on the date of
installation of the Product or 30 days after the date of purchase, whichever occurs rst, and is effective until the specied anniversary of such date as follows:
Item Period of Coverage
Heat Exchanger 2 years All other parts 2 years
Coverage’s are void if the unit is used in a hot water circulation loop, in series with a circulation system or where an on-demand recirculation system is not incorporated.
Owner is responsible for all other costs incidental to repair such as labor, shipping, delivery and permits. Proof of purchase required. Products repaired will be covered under this Limited Warranty for the remainder of term of the original purchase.
Exclusions
Please refer to the Installation Manual and Use & Care Manual supplied with your new Eccotemp Systems product. This Limited Warranty becomes null and void if any of the following are determined to be a contributing factor by Eccotemp to the failure of the product:
1. Abuse, misuse, alteration, neglect or misapplication.
2. Improper, dangerous, destructive maintenance procedures or inadequate maintenance.
3. Damages caused by services performed by servicers other than Eccotemp Systems.
4. Installation in a corrosive or otherwise destructive environment.
5. Damage as a result of freezing within the unit or surrounding piping.
6. Scale buildup.
7. Incorrect gas or water pressure.
8. Acts of force Majeure.
9. Damage as a result of use with non-portable, untreated or poorly treated well water, or water with high
PH levels or hardness levels in excess of 12 grains per gallon (200mg/L).
10. Incorrect sizing for the application.
11. Products with original serial numbers that have been removed or altered and cannot be readily determined.
12. Acts of God including, but not limited to; re, ood, or nature disaster.
Page 35
33
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
This Product is not to be used as a pool or spa heater.
In the event of an Eccotemp Systems recognized defect, malfunction, or failure to conform to this Warranty and based upon Eccotemp approval of warranty claim, Eccotemp Systems, at its sole and absolute discretion, will settle the warrant claim of such defect, malfunction, or failure to conform to this Warranty. In order to make a claim under this Warranty, The Owner must notify Eccotemp of the failure of the Product to conform to this Warranty.
Under this Warranty, Eccotemp Systems will only provide replacement parts as described in the “Limited Warranty
Period”. The Owner will be responsible for any cost incurred including labor costs for servicing the unit, shipping,
delivery, and handling of the replacement part, cost for permits or materials necessary for the repair, or incidental costs resulting from damage external to the unit resulting from the failure.
NOTWITHSTANDING ANYTHING IN THIS WARRANTY TO THE CONTRARY, EXCEPT FOR ECCOTEMP SYSTEMS’ AFFIRMATIVE OBLIGATIONS EXPRESSLY SET FORTH IN THIS WARRANTY, ECCOTEMP SYSTEMS DISCLAIMS ANY AND ALL WARRANTIES, EITHER EXRESS OR IMPLIED, REGARDING THE PRODUCT AND ITS FUNCTIONALITY, PERFORMANCE, MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE OR INTELLECTUAL PROPERTY RIGHTS. ECCOTEMP SYSTEMS DISCLAIMS ALL OTHER OBLIGATIONS OR LIABILITIES ON ITS PART AND NEITHER ASSUMES
NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR ECCOTEMP SYSTEMS AN OTHER LIABILITIES IN
CONNECTION WITH THE PERFORMANCE OF THE PRODUCT. THIS WARRANTY ONLY COVERS REPLACEMENT PARTS AND DOES NOT COVER COST OF LABOR OR SERVICES UNDER ANY CIRCUMSTANCES.
Systems by any other part for damages of any kind, including, but not limited to incidental and consequential damages, arising out of the subject matter of this Agreement. Some States do not allow exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty
gives you specic legal rights. You may also have other rights that vary from State to State.