RM 100 Room climate Monitor (CO2+Temp.+rH) Operating Instructions
1. Green LED Display (<800ppm)
2. Yellow LED Display (800-1200ppm)
3. Red LED Display (>1200ppm & buzzer alarm)
7. Screw Position
8. Ventilation Slots
1. 2 min. warm-up time when powering up for the first time.
2. The LCD shows 4 bars with 1sec blank cycle during warm-up
3. The MUTE button is disabled during warm-up
4. The device shows the CO2 reading after warm-up
Press MUTE button to select buzzer on/off. If the “MUTE” function is off, while CO2 concentration exceed the alarm level (>1200 ppm), there will be a buzzer.
Note: The device setting of the alarm is buzzer on when power on first time, user can set the alarm on/off under MUTE function.
Product Overview
Thank you for selecting the RM 100 Room climate monitor. It is a smart, compact and easy-to-use device. In addition to measuring the CO2
concentration, the RM 100 can also measure the ambient temperature and the relative humidity (CO2+Temp. +rH). This product is developed
to help people taking care of the Indoor Air Quality. The RM 100 can be widely used in office buildings, schools, exhibition halls, shopping malls,
meeting rooms, fitness centers, restaurants and other public places where personal comfort and a healthy environment is important.
Features:
Three different LEDs show the current Indoor Air Quality
MUTE button for alarm on/off.
Built-in LCD backlight for easy reading in the dark
Warnings:
Please take off the AC power adapter and store it well when this CO2 monitor left is idle for
long.
This CO2 monitor is for home use, not suitable for certifying test results.
EMC/RFI
Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per meter, but the
performance of the instrument will not be permanently affected.
Note: Within an electromagnetic field of 3V/m, the reading will not meet the specification.
Warm-Up Time: 2 MIN.
Using the MUTE function:
Safety Instructions
Your safety is very important to us .To ensure using the product correctly and safely, we would like to draw your attention to read the warning and the entire user
manual before using the product. These are important safety information and should be observed at all times.
1. Please handle the devices lightly, do not subject the product to impact or shock. Otherwise, this may cause an accuracy drift.
2. Do not immerse the product in water. Water can cause electric shock, fire or malfunction which may result in damage.
3. Do not keep the product under hot and moisture environments. Keep the product away from heat sources or near water.
4. Please use only the included power adaptor. Improper power adaptors or power sources can cause serious damage to the product, or result in injury or death
to the user.
Caring for the product
To ensure you gain the maximum benefit from using this product, please observe the follow guidelines.
1. Cleaning— Disconnect the power before clean. Use a damp cloth, do not use a liquid cleaning agent, such as benzene, thinner or aerosols.
2. Repair— Do not attempt to repair the product or modify the circuitry by yourself. Please contact with the local dealer or a qualified repairman if the product
needs servicing.
3. Air diffusion— The ventilation slots on the housing are designed for CO2 diffusion, so these ventilation slots should not be blocked.
SPECIFICATIONS
1ppm at 0~1,000ppm; 5ppm at 1,001~2,000ppm; 10ppm at 2,001~3,000ppm
Under 25°C: ±80 ppm or ±5% of reading (≦2000ppm); ±7% reading (>2000ppm)
Typ. ±0.2% of reading per °C or ±2 ppm per °C, whichever is greater, referenced to 25°C
About 2min for 63% of step change
Green: <800ppm; Yellow: 800~1200ppm;Red: >1200ppm
Temperature Specification:
0°C to 50°C (32°F to 122°F) display
±1°C( ±2°F) When the fan blows to the device directly, the accuracy of temperature is + / -1.5 degC
20-30 minutes (case must equalize with environment)
<5 min for 63% of step change
0°C to 50°C (32°F to 122°F)
0 ~ 95% rH non-condensing
-20°C to 60°C( -4°F to 140°F)
USB or 5 VDC from external AC/DC adapter which is included in package (Use specified AC adapter only)
AC Input voltage & Frequency
100 ~ 240 VAC, 0.2A 50 / 60 Hz
The ambient temperature has exceeded the operating
temperature range 0°C to 50°C (32°F to 122°F)
This error will clear when the temperature returns to the range between
0°C to 50°C (32°F to 122°F).
「 」
EEPROM System Problem
Please reconnect AC adapter to the RM 100.
If the “Err5, Err6” still appears, please contact the Service Department for
further assistance.
WTW GmbH – Geschäftsbereich ebro Electronic
Peringerstr. 10 – 85055 Ingolstadt - Germany.
Tel. +49 841 95478-0
ebro@xyleminc.com
http://www.ebro.com
Method -Dual Beam NDIR (Non-Dispersive-Infrared)
Display - LCD Independent CO2, rH and temperature readings
Sample Method - Diffusion or flow through (50 ~200 ml/min).
CO2, rH & Temperature Specification:
Power Supply:
Dimensions
Error Codes & Troubleshooting Guide