ebm-papst K3G097-AK34-43 Data Sheet

K3G097-AK34-43
Nominal data
Type K3G097-AK34-43
Motor M3G074-CF
EC dual centrifugal fan
forward-curved, dual-intake
with housing, Automotive
ebm-papst Mulfingen GmbH & Co. KG
Nominal voltage range VDC 16 .. 32
Method of obtaining data ml
Speed (rpm) min-13600
Power consumption W 325
Current draw A 12.5
Min. ambient temperature °C -40
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment Subject to change
Data according to Commission Regulation (EU) 327/2011 (EN 17166)
Actual Req. 2015
01 Overall efficiency η
es
02 Measurement category A
03 Efficiency category Static
04 Efficiency grade N 55.3 44
05 Variable speed drive Yes
Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller combination in a standardized measurement setup.
% 44.9 33.6
09 Power consumption P
09 Air flow q
09 Pressure increase p
10 Speed (rpm) n min
11 Specific ratio
*
Specific ratio = 1 + pfs/ 100 000 Pa LU-171155
e
v
fs
*
kW 0.22
m³/h 510
Pa 625
-1
4845
1.01
Item no. 50627-5-9980 · ENU · Change 212353 · Approved 2020-05-20 · Page 1 / 5
K3G097-AK34-43
EC dual centrifugal fan
forward-curved, dual-intake
with housing, Automotive
Technical description
Weight 2.3 kg
Size 97 mm
Motor size 74
Impeller material PA plastic
Housing material PP plastic
Number of blades 34
Balancing grade according to DIN ISO 1940-1
Direction of rotation Clockwise, viewed toward rotor
Degree of protection Motor IP24 KM
Insulation class "B"
Moisture (F) / Environmental (H) protection class
Max. permitted ambient temp. for motor (transport/storage)
Min. permitted ambient temp. for motor (transport/storage)
Installation position Any
Condensation drainage holes None, open rotor
Mode S1
Motor bearing Ball bearing; (sealed)
Life expectancy 40,000 h (typical)
Technical features - Lowering input
EMC regulations According to ECE R10 Rev. 3
Electrical hookup Plug; Standby current less than 500 µA
Motor protection Reverse polarity and locked-rotor protection
Approval R10; EAC
Sound level 76 dB(A), sound power level according to ISO 13347
Comment Type approval number – 036432
G 2.5
H1
+85 °C
-40 °C
- Tach output
- Fault output (high-side switch max. 30 mA)
- INVLIN (inverse linear control input)
- Power limit
- Load dump (58 V)
- Motor current limitation
- Soft start
- Control input 0-10 VDC / PWM
- Overvoltage detection
- Thermal overload protection for electronics
- Line undervoltage detection
Item no. 50627-5-9980 · ENU · Change 212353 · Approved 2020-05-20 · Page 2 / 5
K3G097-AK34-43
Product drawing
EC dual centrifugal fan
forward-curved, dual-intake
with housing, Automotive
1 6-pole header TE Junior Power Timer WE_9901118
1.1 + UB
1.2 GND
1.3 PWM/LIN
1.4 INVLIN
1.5 ABSENK
1.6 Diagnostic output
Accessory part: Cable (460 mm) with mating connector, part no. 02001-4-1021 not included in scope of delivery 6-pole mating connector TE 929504-2, 4x plug contact TE 927771-1, 2x plug contact TE 927768-1
Item no. 50627-5-9980 · ENU · Change 212353 · Approved 2020-05-20 · Page 3 / 5
K3G097-AK34-43
Connection diagram
EC dual centrifugal fan
forward-curved, dual-intake
with housing, Automotive
No. Conn. Designation Function/assignment
1.1 +UB Power supply
1.2 GND Power supply GND, reference ground
1.3 PWM/LIN Analog voltage control input 0-10 V or PWM
1.4 INVLIN Control input, inverse linear
1.5 ABSENK Lowering input
1.6 DIAG Diagnostic output
Item no. 50627-5-9980 · ENU · Change 212353 · Approved 2020-05-20 · Page 4 / 5
K3G097-AK34-43
qv m³/h
cfm
Pfs Pa
in wg
200 400 600 800 1000
0 100 200 300 400 500 600
200
400
600
800
1000
1 2 3 4
1
2
3
4
Curves: Air performance
EC dual centrifugal fan
forward-curved, dual-intake
with housing, Automotive
ρ = 1.15 kg/m³ ± 2 %
Measurement: LU-171155-1
Air performance measured according to ISO 5801 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit.
Measured values
U
V
1
2
3
4
U = Voltage · n = Speed (rpm) · Ped= Power consumption · I = Current draw · qV= Air flow · pfs= Pressure increase
26
26
26
26
n
min
3600
3945
4350
4895
P
-1
W
325
281
266
207
I
ed
A
12.50
10.82
10.21
7.93
q
V
m3/h
1195
965
785
450
p
Pa
0
250
450
650
fs
q
cfm
705
570
460
265
p
V
fs
in. wg
0.00
1.00
1.81
2.61
Item no. 50627-5-9980 · ENU · Change 212353 · Approved 2020-05-20 · Page 5 / 5
Loading...