ebm-papst K1G200-AD49-04 User Manual

K1G200-AD49-04
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com
CONTENTS
CAUSES AND REMEDIES
Translation of the original operating instructions
1. SAFETY REGULATIONS AND NOTES
Please read these operating instructions carefully before starting to work with the device. Observe the following warnings to prevent malfunctions or physical damage to both property and people. These operating instructions are to be regarded as part of this device. If the device is sold or transferred, the operating instructions must accompany it. These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention.
11. SAFETY REGULATIONS AND NOTES
11.1 Levels of hazard warnings
11.2 Staff qualification
11.3 Basic safety rules
11.4 Electrical voltage
21.5 Safety and protective functions
21.6 Electromagnetic radiation
21.7 Mechanical movement
21.8 Emission
21.9 Hot surface
21.10 Transport
21.11 Storage
21.12 Disposal
32. PROPER USE
43. TECHNICAL DATA
43.1 Product drawing
53.2 Nominal data
53.3 Data according to ErP directive
53.4 Technical features
53.5 Mounting data
53.6 Transport and storage conditions
53.7 Electromagnetic compatibility
64. CONNECTION AND START-UP
64.1 Connecting the mechanical system
64.2 Connecting the electrical system
64.3 Connection of the cables
74.4 Connection screen
84.5 Checking the connections
84.6 Switch on device
84.7 Switching off the device
85. MAINTENANCE, MALFUNCTIONS, POSSIBLE
95.1 Cleaning
95.2 Safety test
1.1 Levels of hazard warnings
These operating instructions use the following hazard levels to indicate potentially hazardous situations and important safety regulations:
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Compliance with the measures is mandatory.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or damage of property.
NOTE
A potentially harmful situation can occur and, if not avoided, can lead to property damage.
1.2 Staff qualification
The device may only be transported, unpacked, installed, operated, maintained and otherwise used by qualified, trained and authorised technical staff. Only authorised specialists are permitted to install the device, to carry out a test run and to perform work on the electrical installation.
1.3 Basic safety rules
Any safety hazards stemming from the device must be re-evaluated once it is installed in the end device. Observe the following when working on the unit:
; Do not make any modifications, additions or conversions to the
device without the approval of ebm-papst.
1.4 Electrical voltage
; Check the electrical equipment of the device at regular intervals, refer
to chapter 5.2 Safety test.
; Replace loose connections and defective cables immediately.
WARNING Terminals and connections have voltage even with a unit that is shut off
Electric shock
→ Wait five minutes after disconnecting the voltage at all poles
before opening the device.
CAUTION If control voltage is applied or a speed setpoint is stored, the motor automatically restarts, e.g. after a power failure.
Danger of injury
Item no. 50901-5-9970 · ENG · Revision 83494 · Release 2014-10-16 · Page 1 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
K1G200-AD49-04
Operating instructions
→ Keep out of the danger zone of the device.
→ When working on the device, switch off the mains
supply voltage and secure the latter from being switched on again.
→ Wait until the device stops.
→ After working on the device, remove any used tools or
other objects from the device.
1.5 Safety and protective functions
DANGER Missing safety device and non-functioning safety device
If there is no safety device, you could be seriously injured, for example if you reach into the running device or your hands are sucked into it.
→ Operate the device only with a fixed and isolating safety
protection and a fixed guard grille. The guard must withstand the kinetic energy of a fan blade detaching at maximum speed.
→ The device is a built-in component. You, the owner/
operator, are responsible for providing adequate protection for the device.
→ Shut down the device immediately if you detect a
missing or ineffective protective feature.
1.6 Electromagnetic radiation
Interference from electromagnetic radiation is possible, e.g. in conjunction with open and closed-loop control devices. If unacceptable emission intensities occur when the fan is installed, appropriate shielding measures have to be taken by the user.
NOTE Electrical or electromagnetic interferences after integrating the device in installations on the customer's side.
→ Verify that the entire setup is EMC compliant.
1.7 Mechanical movement
DANGER Rotating device
Body parts that come into contact with the rotor and impeller can be injured.
→ Secure the device against accidental contact.
→ Before working on the system/machine, wait until all
parts have come to a standstill.
WARNING Rotating device
Long hair, loose items of clothing and jewellery could become entangled and pulled into the device. You could be injured.
→ Do not wear any loose clothing or jewellery while working
on rotating parts.
Translation of the original operating instructions
→ Protect long hair by wearing a cap.
1.8 Emission
WARNING Depending on the installation and operating conditions, a sound pressure level greater than 70 dB(A) may arise.
Danger of noise-induced hearing loss
→ Take appropriate technical safety measures.
→ Protect operating personnel with appropriate safety
equipment, e.g. hearing protection.
→ Also observe the requirements of local agencies.
1.9 Hot surface
CAUTION High temperature at the electronics enclosure
Danger of burn injuries
→ Ensure that sufficient protection against accidental contact is
provided.
1.10 Transport
NOTE Transport of device
→ Transport the device in its original packaging only.
→ Secure the device so that it does not slip, e.g. by using a
clamping strap.
1.11 Storage
; Store the device, partially or fully assembled, in a dry and
weatherproof manner in the original packing in a clean environment.
; Protect the device from environmental impacts and dirt until the final
installation.
; We recommend storing the device for a maximum up to one year to
guarantee proper operation and longest possible service life.
; Even devices explicitly suited for outdoor use are to be stored as
described prior to being commissioned.
; Maintain the storage temperature, see
chapter 3.6 Transport and storage conditions.
1.12 Disposal
When disposing of the device, please comply with all relevant requirements and regulations applicable in your country.
Item no. 50901-5-9970 · ENG · Revision 83494 · Release 2014-10-16 · Page 2 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
K1G200-AD49-04
Operating instructions
2. PROPER USE
The device is exclusively designed as a built-in device for moving air according to its technical data. Any other or secondary use is deemed improper and constitutes a misuse of the device. Installations on the customer's side must meet the mechanical, thermal and service life-related stresses that can occur.
Proper use also includes:
Use the device in DC power systems only.
Moving air with a density of 1.2 kg/m³.
Using the device in accordance with the permitted ambient
temperature, see chapter 3.6 Transport and storage conditions and chapter 3.2 Nominal data.
Operating the device with all protective features in place.
Minding the operating instructions.
Improper use
Using the device in the following ways is particularly prohibited and may cause hazards:
Operating the device with an imbalance, e.g. caused by dirt deposits
or icing.
Moving air that contains abrasive particles.
Moving highly corrosive air, e.g. salt spray mist. Exceptions are
devices that are intended for salt spray mist and protected accordingly.
Moving air that contains dust pollution, e.g. suctioning off saw dust.
Operating the device close to flammable materials or components.
Operating the device in an explosive atmosphere.
Using the device as a safety component or for taking on safety-
related functions.
Operation with completely or partially disassembled or modified
protective features.
In addition, all application options that are not listed under proper use.
Translation of the original operating instructions
Item no. 50901-5-9970 · ENG · Revision 83494 · Release 2014-10-16 · Page 3 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
K1G200-AD49-04
3. TECHNICAL DATA
3.1 Product drawing
Operating instructions
All measures have the unit mm.
1 Connection line AWG20, 4x brass lead tips crimped 2 Direction of air flow "V"
Translation of the original operating instructions
Item no. 50901-5-9970 · ENG · Revision 83494 · Release 2014-10-16 · Page 4 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
K1G200-AD49-04
Operating instructions
3.2 Nominal data
Motor M1G074-BF
Nominal voltage / VDC 48 Nominal voltage
36 .. 57
range / VDC
Type of data definition fa State prelim. Speed / min
-1
3650
Power input / W 120 Current draw / A 3.4 Max. back pressure / Pa 410 Min. ambient temperature
-25
/ °C Max. ambient
60
temperature / °C
ml = Max. load · me = Max. efficiency · fa = Running at free air cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category A Efficiency category Static Variable speed drive Yes Specific ratio
*
Specific ratio = 1 + pfs / 100 000 Pa
*
1.00
Actual Request
2013
Request 2015
Overall efficiency ηes / % 47.9 27.5 30.5 Efficiency grade N 67.4 47 50 Power input Pe / kW 0.14 Air flow qv / m³/h 620 Pressure increase total psf / Pa 351 Speed n / min
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised measurement configuration.
-1
3645
3.4 Technical features
Operation mode S1 Motor bearing Ball bearing Technical features - Tach output
- Motor current limit
- Soft start
- Control input 0-10 VDC / PWM
Motor protection Reverse polarity and locked-rotor
protection
Cable exit Lateral Product conforming
EN 60950-1
to standard Approval CSA C22.2 Nr.77; UL 1004-1
For cyclic speed loads, note that the rotating parts of the device are designed for maximum one million load cycles. If you have specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
8.8
mounting screws
You can obtain additional mounting data from the product drawing if necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
+ 80 °C
ambient motor temp. (transp./ storage) Min. permissible
- 40 °C
ambient motor temp. (transp./storage)
3.7 Electromagnetic compatibility
EMC interference immunity EMC interference emission
Acc. to EN 61000-6-2 (industrial environment) Acc. to EN 55022 (Class B)
Mass 1.8 kg Size 200 mm Surface of rotor Coated in black Material of impeller Plastic PA6, fibreglass-reinforced Housing material Plastic PA6, fibreglass-reinforced Material of support
Plastic PA6, fibreglass-reinforced
bracket Number of blades 7 Direction of air flow "V" Direction of rotation Clockwise, seen on rotor
Translation of the original operating instructions
Type of protection IP 44; Depending on installation and
position
Insulation class "B" Humidity class F4-1 Mounting position Any Condensate discharge
None
holes
Item no. 50901-5-9970 · ENG · Revision 83494 · Release 2014-10-16 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
K1G200-AD49-04
Operating instructions
4. CONNECTION AND START-UP
4.1 Connecting the mechanical system
CAUTION Cutting and crushing hazard when removing the fan from the packaging
→ Carefully remove the fan from its packaging. Make sure to
avoid any shock.
→ Wear safety shoes and cut-resistant safety gloves.
; Check the device for transport damage. Damaged devices must no
longer be installed.
; Install the undamaged device according to your application.
4.2 Connecting the electrical system
CAUTION Electrical voltage
The fan is a built-in component and features no electrically isolating switch.
→ Only connect the fan to circuits that can be switched off with
an all-pole separating switch.
→ When working on the fan, you must switch off the
installation/machine in which the fan is installed and secure it from being switched on again.
NOTE Water penetration into leads or wires
Water enters at the cable end on the customers side and can damage the device.
→ Make sure that the cable end is connected in a dry
environment.
Operate the device with a safely isolated power pack.
4.3 Connection of the cables
External leads are brought out of device.
Connect the lines according to your application. When doing so,
observe chapter 4.4 Connection screen.
4.2.1 Prerequisites
; Check whether the data on the type plate agree with the connection
data.
; Before connecting the device, ensure that the supply voltage matches
the operating voltage of the device.
; Only use cables designed for current according to the type plate.
For determining the cross-section, follow the basic principles in accordance with EN 61800-5-1. The protective earth must have a cross-section equal to or greater than the outer conductor cross­section. We recommend the use of 105°C cables. Ensure that the minimum cable cross-section is at least AWG26/0.13 mm².
4.2.2 Idle current
Because of the EMC filter integrated for compliance with EMC
Translation of the original operating instructions
limits (interference emission and interference immunity), idle currents in the mains cable can be measured even when the motor is at a standstill and the mains voltage is switched on.
Item no. 50901-5-9970 · ENG · Revision 83494 · Release 2014-10-16 · Page 6 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
K1G200-AD49-04
4.4 Connection screen
Operating instructions
No. Conn. Designation Colour Function / assignment 1 1 Un +48 VDC red Power supply 48 VDC, residual ripple 3.5 % 1 2 0-10 VDC yellow Control input Re > 100 K 1 3 Tach white Speed monitoring output, 3 pulses per rotation, Isink max = 10 mA 1 4 GND blue Reference mass
Translation of the original operating instructions
Item no. 50901-5-9970 · ENG · Revision 83494 · Release 2014-10-16 · Page 7 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
K1G200-AD49-04
Operating instructions
4.5 Checking the connections
; Make sure that the power is off (all phases).
; Secure it from being switched on again.
; Check the correct fit of the connection lines.
4.6 Switch on device
The device may only be switched on if it has been installed properly and in accordance with its intended use, including the required safety mechanisms and professional electrical connection. This also applies for devices which have already been equipped with plugs and terminals or similar connectors by the customer.
WARNING Hot motor housing
Fire hazard
→ Ensure that no combustible or flammable materials are
located close to the fan.
; Inspect the device for visible external damage and the proper function
of the protective features before switching it on.
; Check the air flow paths of the fan for foreign objects and remove any
that are found.
; Apply the nominal voltage to the voltage supply.
; Start the device by changing the input signal.
4.7 Switching off the device
Switching off the device during operation:
; Switch off the device via the control input.
; Do not switch the motor (e.g. in cyclic operation) on and off via power
supply.
Switching off the device for maintenance work:
; Switch off the device via the control input.
; Do not switch the motor (e.g. in cyclic operation) on and off via power
supply.
; Disconnect the device from the supply voltage.
Translation of the original operating instructions
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES
Do not perform any repairs on your device. Return the device to ebm­papst for repair or replacement.
WARNING Terminals and connections have voltage even with a unit that is shut off
Electric shock
→ Wait five minutes after disconnecting the voltage at all poles
before opening the device.
CAUTION If control voltage is applied or a speed setpoint is stored, the motor automatically restarts, e.g. after a power failure.
Danger of injury
→ Keep out of the danger zone of the device.
→ When working on the device, switch off the mains
supply voltage and secure the latter from being switched on again.
→ Wait until the device stops.
→ After working on the device, remove any used tools or
other objects from the device.
If the device remains out of use for some time, e.g. when in storage, we recommend switching the device on for at least two hours to allow any condensate to evaporate and to move the bearings.
Malfunction/error Possible cause Possible remedy Impeller running roughly
Motor does not turn Mechanical blockage Switch off, de-
Imbalance in rotating parts
Mains supply voltage faulty
Faulty connection De-energise, correct
Clean the device; if imbalance is still evident after cleaning, replace the device. If you have attached any weight clips during cleaning, make sure to remove them afterwards.
energise, and remove mechanical blockage. Check mains supply voltage, restore power supply, apply control signal.
connection, see connection diagram.
Item no. 50901-5-9970 · ENG · Revision 83494 · Release 2014-10-16 · Page 8 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
K1G200-AD49-04
Operating instructions
Overtemperature of electronics/motor
If you have any other problems, contact ebm-papst.
5.1 Cleaning
NOTE Damage to the device during cleaning.
Malfunction possible
→ Do not clean the device using a water jet or high-pressure
washer.
→ Do not use any cleaners containing acids,
bases or solvents.
→ Do not use any pointed or sharp-edged objects to clean.
Insufficient cooling Improve cooling. Let
the device cool down. To reset the error message, switch off the mains supply voltage for a min. of 25 s and switch it on
again. Ambient temperature too high
Unacceptable operating point
Reduce the ambient
temperature.
Reset by reducing
control input to 0.
Correct the operating
point. Let the device
cool down.
5.2 Safety test
What has to be tested?
Check the protective casing against accidental contact for damage and to ensure that it is intact Device for damage Mounting the connection lines Check the insulation of the wires for damage Impeller for wear/deposits/
Translation of the original operating instructions
corrosion and damage
How to test? Frequency Which
Visual inspection At least every
Visual inspection At least every
Visual inspection At least every
Visual inspection At least every
Visual inspection At least every
6 months
6 months
6 months
6 months
6 months
measure?
Repair or replacement of the device
Replace device
Fasten
Replace wires
Clean or replace impeller
Item no. 50901-5-9970 · ENG · Revision 83494 · Release 2014-10-16 · Page 9 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Loading...