EBARA DLFU, DLFMU Instruction Manual

Page 1
Model DLFU, DLFMU
Instruction Manual
CALL 1-800-577-8111 FOR SALES AND SUPPORT
CALL 1-800-577-8111 FOR SALES AND SUPPORT
Page 2
Motor type Air filled submersible motor Shaft seal lubrication oil Turbine No. 32 ISO VG - 32
CALL 1-800-577-8111 FOR SALES AND SUPPORT
Maximum water depth 65 ft
EBARA Submersible Sewage Pumps DLFU/DLFMU
Installation with Quick Discharge Connector or floor mounted
Instruction Manual
Project: Model: Chk’d: Date:
rev. 02/02
Design of this EBARA pump is based on superior engineering and long experience. To prevent trouble and provide satisfactory operation and long life, it is important to understand the EBARA pump thoroughly by careful study of this manual. If any questions arise regarding this manual, please direct them to EBARA INTERNATIONAL CORPORATION.
Specifications
Page 3
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
EBARA International Corporation Standard Pump Division 3
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
Installation
1. Check the following before beginning installation:
Insulation resistance measurement: (1) For three phase motor:
With the motor and cable (excluding the power supply connections) immersed in water, use a meggar to measure the insulation resistance between, the ground wire and each phase of the motor.
Pump Checks
1. Check the following points upon receipt of your pump:
(1) Check the name plate to confirm that it is the pump
ordered.
(2) Ensure that the pump voltage is the same as the power
at your location.
(3) Check oil level at oil plug. (4) Check that all plugs and fastening bolts are properly
tightened.
(5) Check that the pump has not been damaged and the
cable glands and cables are in a satisfactory condition.
(6) Check accessories and spare parts against the packing
list.
(7) Check that the impeller turns smoothly by hand.
2. Precautions when operation is suspended:
(1) If operation is to be suspended for 30 days with the pump
immersed in water, measure the insulation resistance of the motor. If resistance is over 1 mega ohm, operate pump to prevent rust from developing on moving parts. Follow the instructions under OPERATION when pump operation is to be resumed.
(2) For dry storage, clean out pump and store in a dry place.
Follow the instructions under INSTALLATION and OPERATION when pump operation is to be resumed.
WARNING
Before insulation resistance measurement, always disconnect the power first.
All electrical work should be performed by a qualified electrician and all national and local electrical codes must be observed.
CAUTION
When measuring the insulation resistance with meggar for motor windings do not test overload protection.
MINIATURE THERMAL PROTECTION (MTP) AND LEAKAGE DETECTOR (LD) ARE USED FOR MOTOR PROTECTION. MTP AND LD CABLES MUST BE INSTALLED IN CONTROL CIRCUIT.
CAUTION
Measure the insulation resistance. The value should be more than I mega ohm. While making the measurement, keep the power supply cable off the ground.
Page 4
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
EBARA International Corporation Standard Pump Division 4
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
Installation
2. Pump Installation
1. Clean the installation area.
2. Under no circumstances should the cable be pulled while the pump is being transported or installed. Attach a chain or rope to the grip and install the pump.
3. This pump must not be installed on its side. Ensure that it is installed upright on a secure base.
4. Install the pump at a location in the tank where there is the least turbulence.
5. If there is a flow of liquid inside the tank, support the cable where appropriate (See Fig. 1).
6. Install piping so that air will not be entrapped. If piping must be installed in such a way that air pockets are unavoidable, install an air release valve wherever such air pockets are most likely to develop.
7. Do not permit end of discharge piping to be submerged, as backflow will result when the pump is shut down.
8. Non-automatic pumps (model DLFU, DLMFU) do not have an automatic operating system based on built-in floats. Do not operate the pump for a long time with the water level near the minimum operating level as the automatic cut-off switch incorporated inside the motor will be activated.
To avoid dry operation, install an automatic operating system, as shown in Fig. 2 and maintain a safe operating water level.
WARNING
When lifting the pump, use appropriate crane (or hoist) and lift system, check position and tightness of lift system so that weight of the pump is not UNBALANCED. Failure to observe this precaution can result in serious accidents. Handle the cables very carefully. If they are bent or pulled excessively, the cable and the moulded seal may be damaged, resulting in insulation failure. Also, care is needed to protect cable ends against water intrusion.
CAUTION
Before installation check rotation. Correct rotation is clockwise when viewed from top of motor. Read ELECTRICAL WIRING.
Fig. 1
Fig. 2
H1: Operating water level
This must be above the top of the motor.
H
2
: Lowest water level (motor flange)
Page 5
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
EBARA International Corporation Standard Pump Division 5
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
Installation
3. Electrical Wiring:
(1) Wiring
a) Wire as indicated for the appropriate start system as shown in Fig. 3. b) Loose connections will stop the pump. Make sure all electrical connections are secure.
Output 2 to 10HP
208/230V 460V
Output 15 to 30HP
208/230V 460V
Output 40 to 60HP
208/230V 460V
WARNING
Check that the power is locked off and disconnected before working on pump. All electrical work should be performed by a qualified electrician and all national and local electrical codes must be observed.
G – GRN L1– RED – T1– T
7
L2– WHT – T2– T
8
L3– BLK – T3– T
9
T4– T5– T6– T10– T11– T
12
P1– RED
P2– WHT
P3– BLK
P4– OR
G – GRN
G– GRN L1– RED – T1 – T
12
L2– WHT – T2 – T
10
L3– BLK – T3 – T
11
T4– T
7
T5 – T
8
T6 – T
9
P1– RED
P2– WHT
P3– BLK
P4– ORG
G – GRN
G – GRN L
1
– RED – T1– T7 – T6 – T
12
L2– WHT – T4– T8 – T2 – T
10
L3– BLK – T3– T9 – T5 – T
11
P1– RED P
2
– WHT
P
3
– BLK
P
4
– ORG
G – GRN
G– GRN L1– RED – T
1
L2– WHT – T
2
L3– BLK – T
3
L5– WHT – T
10
L6– BLK – T
11
L4– RED – T
12
T4– T
7
T5 – T
8
T6 – T
9
P1– RED
P2– WHT
P3– BLK
P4– OR
G – GRN
G – GRN L1– RED – T1– T
7
L2– WHT – T2– T
8
L3– BLK – T3– T
9
L5– WHT – T4– T
10
L6– BLK – T5– T
11
L4– RED – T6– T
12
P1– RED
P2– WHT
P3– BLK
P4– ORG
G – GRN
G– GRN L1– RED – T
1
L2– WHT – T
2
L3– BLK – T
3
T4– T
7
T5– T
8
T6– T
9
T
10
– T11– T
12
P1– RED
P2– WHT
P3– BLK
P4– ORG
G – GRN
Page 6
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
EBARA International Corporation Standard Pump Division 6
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
Installation
(2) Cable
a) Never let the end of the cable contact water b) If the cable is extended, do not immerse the splice in
water.
c) Fasten the cable to the discharge piping with tape or
vinyl strips.
d) Install the cable so that it will not overheat.
Overheating is caused by coiling the cable and exposing it to direct sunlight.
(3) Grounding
As shown in Fig. 4 ground the green wire (label E). Under no circumstances should the green wire be connected to the power supply.
(4) Use short circuit breakers to prevent danger of electrical
shock.
Operation
1. Before starting the pump:
(1) After completing installation, measure the insulation resistance again as described in INSTALLATION. (2) Check water level. If the pump is operated continuously for an extended period of time in a dry condition or at the lowest water level, the thermal protector will be activated. Constant repetition of this action will shorten pump service life. Do not start the pump again in such a situation until after the motor has completely cooled.
2. Test Operation:
(1) Model DLFU, DLMFU
a) Turn the operating switch on and off a couple of times to check for normal pump start. b) Check the direction of rotation. If discharge volume is low or unusual sounds are heard when the pump is operating,
rotation has been reversed. When this happens, reverse two of the three wires.
c) Check amperage, voltage, and head pressure.
Maintenance and Service
Check pressure, output, voltage, current, vibration, and other specifications. Unusual readings may indicate a problem requiring immediate service. Contact your local EBARA INTERNATIONAL CORPORATION representative as soon as possible.
CAUTION
Check rotation. Correct rotation is clockwise when viewed from top of motor. Pump should be started with gate valve closed, and then the operator should open the valve gradually.
Fig. 4
WARNING
Disconnect power cable from power source before servicing unit. Normal maintenance should be done by qualified personnel.
Page 7
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
EBARA International Corporation Standard Pump Division 7
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
Maintenance and Service
1. Daily inspections:
(1) Check current and ammeter fluctuation daily. If ammeter fluctuation is great, even though within the limits of pump
rating, foreign matter may be clogging the pump. If the quantity of liquid discharged falls suddenly, foreign matter may be blocking the suction inlet.
2. Regular inspections:
(1) Monthly inspections
Measure the insulation resistance. The value should be more than 1 mega ohm. If resistance starts to fall rapidly even with an initial indication of over 1 mega ohm, this may be an indication of trouble and repair work is required.
(2) Every 6 months
Check the mechanical seal every six months. If you notice water mixed with the oil or cloudy texture of the oil, these may be indications of a defective mechanical seal requiring replacement. The service life of the mechanical seal can be prolonged by replacing the oil in the mechanical seal chamber once a year. When replacing the oil, lay the pump on its side, with filler plug on top as shown in Fig. 5.
For over 7
1
/2 HP motors, inject turbine oil No. 32 (ISO VG-32) until it overflows. For motors of less than 5 HP, inject the
amount specified in Table 1. Be certain to dispose of oil residue properly.
(3) Preventive maintenance yearly
Conduct an overhaul of the pump annually. These intervals will reduce the possibility of future trouble.
3. Parts that will need to be replaced:
Replace the appropriate part when the following conditions are apparent.
Above replacement schedule is based on normal operating conditions.
Fig. 5
Table 1
HP Oil
2 40 ozs 3 50 ozs 5 50 ozs
7
1
/
2
90 ozs 10 90 ozs 15 120 ozs
HP Oil
20 210 ozs 25 210 ozs 30 210 ozs 40 220 ozs 50 240 ozs 60 240 ozs
Replaceable Part Mechanical Seal Oil Filter plug gasket Lubricating oil O-ring
Whenever oil in Whenever oil is Whenever clouded Whenever pump
Replacement guide mechanical seal replaced or or dirty is overhauled
chamber is clouded inspected
Frequency Annually Annually Annually Annually
Page 8
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
EBARA International Corporation Standard Pump Division 8
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
Troubleshooting
CAUTION
All service should be done by factory trained or qualified personnel only.
Trouble Cause Remedy
Does not start. (1) Power failure (1)-(3) Contact electric power company; devise counter-measures Starts, but (2) Large discrepancy between power source and voltage immediately stops. (3) Significant drop in voltage
(4) Motor phase malfunction (4) Inspect connections and magnetic switch (5) Electric circuit connection faulty (5) Inspect electric circuit (6) Faulty connection of control circuit (6) Correct wiring (7) Blown fuse (7) Replace with correct type of fuse (8) Faulty magnetic switch (8) Replace with correct type of magnetic switch (9) Water is not at level indicated by float (9) Raise water level (10) Float is not in appropriate level (10) Move float to an appropriate starting level (11) Float defective (11) Repair or replace (12) Short circuit breaker is functioning (12) Repair location of short circuit (13) Foreign matter clogging pump (13) Remove foreign matter (14) Motor burned out (14) Repair or replace (15) Motor bearing broken (15) Repair or replace
Operates, but stops (1) Prolonged dry operation has activated motor protector (1) Raise stop water level after a while. and caused pump to stop
(2) High liquid temperature has activated motor protector (2) Lower liquid temperature and caused pump to stop
Does not pump. (1) Reverse rotation (1) Correct rotation (see Operation 2, (3)) Inadequate volume. (2) Significant drop in voltage (2) Contact electric power company and devise
counter-measures (3) Operating a 60Hz pump on 50Hz (3) Check nameplate (4) Discharge head is high (4) Recalculate and adjust (5) Large piping loss (5) Recalculate and adjust (6) Low operating water level causes air suction (6) Raise water level or lower pump (7) Leaking from discharge piping (7) Inspect, repair (8) Clogging of discharge piping (8) Remove foreign matter (9) Foreign Matter in suction inlet (9) Remove foreign matter (10) Foreign matter clogging pump (10) Disassemble and remove foreign matter (11) Worn impeller (11) Replace impeller
Over current (1) Unbalanced current and voltage (1) Contact electric power company and devise counter-measure
(2) Significant voltage drop (2) Contact electric power company and devise counter-measure (3) Motor phase malfunction (3) Inspect connections and magnetic switch (4) Operating 50HZ pump on 60Hz (4) Check nameplate (5) Reverse rotation (5) Correct rotation (see Operation 2. (3)) (6) Low head; excessive volume of water (6) Replace pump with low head pump (7) Foreign matter clogging pump (7) Disassemble and remove foreign matter (8) Motor bearing is worn or damaged (8) Replace bearing
Pump vibrates; (1) Reverse rotation (1) Correct rotation excessive operating (2) Pump clogged with foreign matter (2) Disassemble and remove foreign matter noise. (3) Piping resonates (3) Improve piping
(4) Gate valve is closed too far (4) Open gate valve
Single phase motor: (1) Defective start capacitor (1) Replace start capacitor. Motor hums, but will not (2) Defective relay: run, over load trips. a) Check relay coil with continuity meter (2a) Replace relay if open coil is found In approximately 15-20 b) Check for loose or broken connection in relay and (2b) If circuit is intact, replace start capacitor and restart motor seconds. After an off start capacitor circuit time of 30-60 seconds, c) If after step (2b) motor fails to start, check with (2c) If no continuity is indicated, replace relay overload protector will continuity indicator across terminal 162 reclose. If motor again (3) Defective motor; if motor fails to start after replacing (3) Check motor for electrical and mechanical defects hums and overload trips, relay (start or run capacitor if used), motor may be the fault is probably due to defective either a defective start capacitor or relay, or perhaps the motor itself.
Page 9
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
2 to 5HP
EBARA International Corporation Standard Pump Division 9
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
Motors are purchased as a complete unit †: Recommended spare parts
PA RT
NO.
001
005 †012 †021
039
080 †111 †115-1 †115-2 †115-3 †115-4 †117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
125
PART NAME
CASING INTERMEDIATE CASING SUCTION COVER IMPELLER KEY BUSHING MECHANICAL SEAL O-RING O-RING O-RING O-RING GASKET BOLT BOLT BOLT BOLT BOLT BOLT BOLT BOLT
MATERIAL
CAST IRON CAST IRON CAST IRON CAST IRON 420 STAINLESS STEEL
— RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR)
304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS
ASTM, AISI
CODE
A48 Class 30 A48 Class 30 A48 Class 30 A48 Class 30 AISI420 A283 Grade D
AISI304 AISI304 AISI304 AISI304 AISI304 AISI304 AISI304 AISI304
NO. FOR
1 UNIT
1 1 1 1 1 1
1 SET
1 1 1 2 1 4 8 4 4 3 4 2 1
PA RT
NO.
174 193-1 193-2 200 213 801 802 811-1 811-2 814 816 817 830
838 †849-1 †849-2
876
909
924
PART NAME
DISCHARGE ELBOW PLUG PLUG LIFTING HANGER AIR VENT VALVE ROTOR S TATO R POWER CABLE CONTROL CABLE MOTOR COVER BRACKET BRACKET SHAFT WASHER BALL BEARING BALL BEARING MOTOR PROTECTOR LEAKAGE DETECTOR PACKING
MATERIAL
CAST IRON 304 STAINLESS 304 STAINLESS STEEL BRASS
— — —
— CAST IRON CAST IRON CAST IRON 403 STAINLESS 304 STAINLESS
— RUBBER (NBR)
ASTM, AISI
CODE
A48 Class 30 AISI304 AISI304 A283 Grade D B36 No. 272
A48 Class 30 A48 Class 30 A48 Class 30 AISI403 AISI304
NO. FOR
1 UNIT
1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 3 1 2
811
2
120
7
120
6
120
5
115
1
120
2
193
1
120
4
120
3
115
2
193
2
115
3
115
4
849
2
811
1
909
849
830
814
801
802
005
001
111
816
039
012
125
174
117
021
080
838
817
924
876
120
1
213
200
Page 10
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
71/2
to 10HP
EBARA International Corporation Standard Pump Division 10
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
924
2
838
2
115
5
120
6
120
4
115
1
120
3
120
2
115
2
193
1
849
1
193
2
115
4
115
3
849
2
811
1
8381924
1
811
2
120
7
909
802
801
816
039
021
114
111
001
005
125
213
012
117
876
814
817
830
PA RT
NO.
001
005 †012 †021
039 †111 †114 †115-1 †115-2 †115-3 †115-4 †115-5 †117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
125
PART NAME
CASING INTERMEDIATE CASING SUCTION COVER IMPELLER KEY MECHANICAL SEAL OIL SEAL O-RING O-RING O-RING O-RING O-RING GASKET BOLT BOLT BOLT BOLT BOLT BOLT BOLT BOLT
MATERIAL
CAST IRON CAST IRON CAST IRON CAST IRON 420 STAINLESS
— RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR)
304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS
ASTM, AISI
CODE
A48 Class 30 A48 Class 30 A48 Class 30 A48 Class 30 AISI420
AISI304 AISI304 AISI304 AISI304 AISI304 AISI304 AISI304 AISI304
NO. FOR
1 UNIT
1 1 1 1 1
1 SET
1 1 1 1 1 1 1 4 8 4 6 3 4 2 1
PA RT
NO.
174 193-1 193-2 200 213 801 802 811-1 811-2 814 816 817 830 838-1
838-2 †849-1 †849-2
876
909
924-1
924-2
PART NAME
DISCHARGE ELBOW PLUG PLUG LIFTING HANGER AIR VENT VALVE ROTOR S TATO R POWER CABLE CONTROL CABLE MOTOR COVER BRACKET BRACKET SHAFT WASHER WASHER BALL BEARING BALL BEARING MOTOR PROTECTOR LEAKAGE DETECTOR PACKING PACKING
MATERIAL
CAST IRON 304 STAINLESS 304 STAINLESS STEEL BRASS
— — —
— CAST IRON CAST IRON CAST IRON 420J2 STAINLESS 304 STAINLESS 304 STAINLESS
— RUBBER (NBR) RUBBER (NBR)
ASTM, AISI
CODE
A48 Class 30 AISI304 AISI304 A283 Grade D B36 No. 272
A48 Class 30 A48 Class 30 A48 Class 30 AISI420 AISI304 AISI304
NO. FOR
1 UNIT
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1
120
1
174
200
120
5
Motors are purchased as a complete unit †: Recommended spare parts
Page 11
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
15 to 30HP
EBARA International Corporation Standard Pump Division 11
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
9242838
2
115
6
120
7
849
1
120
6
120
5
816
2
115
2
816
1
120
2
193
1
120
3
115
1
120
4
115
3
193
2
115
5
115
4
849
2
811
1
8381924
1
811
2
120
8
213
830
801
802
005
001
111114021039
012
125
117
876
814
817
909
PA RT
NO.
001
005 †012 †021
039 †111 †114 †115-1 †115-2 †115-3 †115-4 †115-5 †115-6 †117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
120-8
125
PART NAME
CASING INTERMEDIATE CASING SUCTION COVER IMPELLER KEY MECHANICAL SEAL OIL SEAL O-RING O-RING O-RING O-RING O-RING O-RING GASKET BOLT BOLT BOLT BOLT BOLT BOLT BOLT BOLT BOLT
MATERIAL
CAST IRON CAST IRON CAST IRON CAST IRON 420 STAINLESS
— RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR)
304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS
ASTM, AISI
CODE
A48 Class 30 A48 Class 30 A48 Class 30 A48 Class 30 AISI420
AISI304 AISI304 AISI304 AISI304 AISI304 AISI304 AISI304 AISI304 AISI304
NO. FOR
1 UNIT
1 1 1 1 1
1 SET
1 1 1 1 1 1 1 1 4 8 4 6 6 3 6 2 1
PA RT
NO.
174 193-1 193-2 200 213 801 802 811-1 811-2 814 816-1 816-2 817 830 838-1
838-2 †849-1 †849-2
876
909
924-1
924-2
PART NAME
DISCHARGE ELBOW PLUG PLUG LIFTING HANGER AIR VENT VALVE ROTOR S TATO R POWER CABLE CONTROL CABLE MOTOR COVER BRACKET BRACKET BRACKET SHAFT WASHER WASHER BALL BEARING BALL BEARING MOTOR PROTECTOR LEAKAGE DETECTOR PACKING PACKING
MATERIAL
CAST IRON 304 STAINLESS 304 STAINLESS STEEL BRASS
— — —
— CAST IRON CAST IRON CAST IRON CAST IRON 420J2 STAINLESS 304 STAINLESS 304 STAINLESS
— RUBBER (NBR) RUBBER (NBR)
ASTM, AISI
CODE
A48 Class 30 AISI304 AISI304 A283 Grade D B36 No. 272
A48 Class 30 A48 Class 30 A48 Class 30 A48 Class 30 AISI420 AISI304 AISI304
NO. FOR
1 UNIT
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1
120
1
174
200
Motors are purchased as a complete unit †: Recommended spare parts
Page 12
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
40 to 60HP 100DLFU
EBARA International Corporation Standard Pump Division 12
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
Motors are purchased as a complete unit †: Recommended spare parts *: Option for hard-piped installations
838
1
120
7
849
1
120
5
115
3
193
2
115
2
115
1
9241811
1
838
2
115
7
115
5
849
2
120
6
115
4
120
4
816
2
816
1
193
1
120
3
120
2
120
1
924
2
811
2
120
8
115
6
817
876
814
830
909
213
200
174
117
167
801
802
111
005
114
001
021
039
080
125
107
PA RT
NO.
001 005
†021
039
080 †107 †111 †114 †115-1 †115-2 †115-3 †115-4 †115-5 †115-6 †115-7 †117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
120-8
PART NAME
CASING INTERMEDIATE CASING IMPELLER KEY BUSHING WEARING RING MECHANICAL SEAL OIL SEAL O-RING O-RING O-RING O-RING O-RING O-RING O-RING GASKET BOLT BOLT BOLT BOLT BOLT BOLT BOLT BOLT
MATERIAL
CAST IRON CAST IRON CAST IRON 420 STAINLESS 304 STAINLESS 304 STAINLESS
— RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR)
304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS
ASTM, AISI
CODE
A48 Class 30 A48 Class 30 A48 Class 30 AISI420 AISI 304 AISI 304
AISI304 AISI304 AISI304 AISI304 AISI304 AISI304 AISI304 AISI304
NO. FOR
1 UNIT
1 1 1 1 1 1
1 SET
1 1 1 1 1 1 2 1 1 8 8 8 8 6 4 6 2
PA RT
NO.
125
*167
174 193-1 193-2 200 213 801 802 811-1 811-2 814 816-1 816-2 817 830 838-1
838-2 †849-1 †849-2
876
909
924-1
924-2
PART NAME
BOLT BASE DISCHARGE ELBOW PLUG PLUG LIFTING HANGER AIR VENT VALVE ROTOR S TATO R POWER CABLE CONTROL CABLE MOTOR COVER BRACKET BRACKET BRACKET SHAFT WASHER WASHER BALL BEARING BALL BEARING MOTOR PROTECTOR LEAKAGE DETECTOR PACKING PACKING
MATERIAL
304 STAINLESS STEEL CAST IRON 304 STAINLESS 304 STAINLESS STEEL BRASS
— — —
— CAST IRON CAST IRON CAST IRON CAST IRON 420J2 STAINLESS 304 STAINLESS 304 STAINLESS
— RUBBER (NBR) RUBBER (NBR)
ASTM, AISI
CODE
AISI304 A283 Grade D A48 Class 30 AISI304 AISI304 A283 Grade D B36 No. 272
A48 Class 30 A48 Class 30 A48 Class 30 A48 Class 30 AISI420 AISI304 AISI304
NO. FOR
1 UNIT
1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1
1 SET
1 3 1 2 1
Page 13
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
40 to 60HP 150DLFU 200DLFU 250DLFU 300DLFU
EBARA International Corporation Standard Pump Division 13
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
Motors are purchased as a complete unit †: Recommended spare parts *: Option for hard-piped installations
838
2
115
7
120
8
120
6
120
7
120
4
816
2
816
1
193
2
120
3
120
2
120
1
924
2
811
2
120
9
811
1
924
1
838
1
115
6
801
802
111
005
114
021
072
039
001
125
200817
876
814
830
909
949
2
115
5
849
1
115
4
115
3
120
5
174
280
117
193
1
115
1
115
2
107 167
PA RT
NO.
001 005
†021
039 †072 †107 †111 †114 †115-1 †115-2 †115-3 †115-4 †115-5 †115-6 †115-7 †117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
120-8
120-9
PART NAME
CASING INTERMEDIATE CASING IMPELLER KEY SIDE RING WEARING RING MECHANICAL SEAL OIL SEAL O-RING O-RING O-RING O-RING O-RING O-RING O-RING GASKET BOLT BOLT BOLT BOLT BOLT BOLT BOLT BOLT BOLT
MATERIAL
CAST IRON CAST IRON DUCTILE IRON 420 STAINLESS CAST IRON 304 STAINLESS
— RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR) RUBBER (NBR)
304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS 304 STAINLESS
ASTM, AISI
CODE
A48 Class 30 A48 Class 30 A536 60-40-18 AISI420 A48 Class 30 AISI304
AISI304 AISI304 AISI304 AISI304 AISI304 AISI304 AISI304 AISI304 AISI304
NO. FOR
1 UNIT
1 1 1 1 1 1
1 SET
1 1 1 1 1 1 2 1 1
3
/
4
4 8 4 8 8 4 6 2
PA RT
NO.
125
*167
174 193-1 193-2 200 280 801 802 811-1 811-2 814 816-1 816-2 817 830 838-1
838-2 †849-1 †849-2
876
909
924-1
924-2
PART NAME
BOLT BASE DISCHARGE ELBOW PLUG PLUG LIFTING HANGER ELBOW SUPPORT ROTOR S TATO R POWER CABLE CONTROL CABLE MOTOR COVER BRACKET BRACKET BRACKET SHAFT WASHER WASHER BALL BEARING BALL BEARING MOTOR PROTECTOR LEAKAGE DETECTOR PACKING PACKING
MATERIAL
304 STAINLESS STEEL CAST IRON 304 STAINLESS 304 STAINLESS STEEL STEEL
— — —
— CAST IRON CAST IRON CAST IRON CAST IRON 420J2 STAINLESS 304 STAINLESS 304 STAINLESS
— RUBBER (NBR) RUBBER (NBR)
ASTM, AISI
CODE
AISI304 A283 Grade D A48 Class 30 AISI304 AISI304 A283 Grade D A283 Grade D
A48 Class 30 A48 Class 30 A48 Class 30 A48 Class 30 AISI420 AISI304 AISI304
NO. FOR
1 UNIT
1 1 1 1 1 1 2 1 1 2 1 1 1 1 1 1 2 1
1 SET
1 3 1 2 1
Page 14
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
EBARA International Corporation Standard Pump Division 14
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
Maintenance and Service
6. Disassembly and Assembly:
Please contact the following for assistance:
Ebara International Corporation Customer Service Manager 1651 Cedar Line Drive Rock Hill, South Carolina 29730
Thermal Protection
The motor shall be equipped with a protector such as automatic cut-off device and thermal protector. The motors described below shall incorporate Miniature Thermal Protectors (MTP) which are embedded in the windings.
When temperature of the winding raises and reaches the MTP acting point, the motor protection circuit is activated to protect motor from over heat.
1. Applicable model
Model: DGFU, DLFU, DVFU, DDLFU
2. MTP Specifications:
Model KLIXON 9700K-66-215 Type of Contact b (Normal-contact Acting-open) Acting Temperature 140±5°C (284±9°F) Re-setting Temperature 85±10°C (185±18°F) Capacity of Contact
3. Installation:
MTP shall be embedded in the stator windings as shown at right –
4. Construction:
Construction of the MTP is as shown below:
CAUTION
All service should be done by factory trained or qualified personnel only. Be sure to cut off power source before beginning disassembly.
Voltage (V)
Amperage (A)
DC 2418AC 11518AC 23013AC 460
5.5
Page 15
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
EBARA International Corporation Standard Pump Division 15
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
Leakage Detector
1. Construction:
Each switch has a magnet-containing float which senses the liquid level and magnetically actuates a dry reed switch encapsulated within a stem. The switch opens on rise of liquid.
2. Specifications
Apply to 2 to 10HP
Breaking Capacity : AC50VA, DC50W
Max. Breaking Current : AC0.5A, DC0.5A
Max. Operating Voltage : AC300V, DC300V
2.
Apply to 15 to 60HP
Breaking Capacity : AC12VA, DC10W
Max. Breaking Current : AC0.6A, DC0.5A
Max. Operating Voltage : AC200V, DC200V
Lead Wire
Float Body
(304 S.S.)
Float
(304 S.S.)
Stopper
(304 S.S.)
Lead Wire
Float Body
(Polypropylene)
Float
(Polypropylene)
Stopper
(316 S.S.)
Open
Close
Close
Open
Page 16
EBARA Submersible Sewage Pumps DLFU/DLFMU
Instruction Manual
EBARA International Corporation Standard Pump Division 16
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
rev. 02/02
Other
1. All specifications subject to change without notice
2. Limited warranty:
EIC warrants for a period of twelve months from the date of initial startup or eighteen months from the date of shipment, whichever shall first occur (the "Warranty Period") the EIC Products to be delivered hereunder against defects in material and workmanship, under normal use and service when installed, used and maintained in accordance with instructions supplied by EIC. This is EIC's sole and exclusive warranty. It applies only to EIC Products and specifically excludes Other Equipment, whether or not such Other Equipment is included in EIC's scope of supply hereunder. Such Other Equipment is warranted only by its manufacturer. If such a defect appears in EIC Products within the Warranty Period and Purchaser has given EIC immediate written notice of same, EIC will either repair the part, or at its option replace the part, by shipping a similar part F.O.B. EIC's shipping point, or at its option refund an equitable portion of the purchase price. EIC may require the return of the defective part, transportation prepaid, to establish the claim. All costs of removal, reinstallation, field labor and transportation shall be borne by the Purchaser. No allowance will be made for repairs without EIC's written consent or approval, and the Warranty Period shall not be suspended upon stopping operation for warranty repairs, nor recommence upon completion of the warranty repairs, but shall run continuously from commencement until normal expiration. Repair parts shall carry no greater warranty than the remaining balance of the underlying EIC Product into which they may be installed, expiring at the same time as said underlying warranty.
Any descriptions of the EIC Products or Other Equipment, any specifications, and any samples, models, bulletins, or similar material used in connection with this sale are for the sole purpose of identifying the said Equipment and are not to be construed as express or implied warranties. Unless during the warranty period all repairs or replacements or parts or components for EIC Products are with EIC-approved parts or components, and all warranty service is performed by EIC or its authorized distributor or representative, the warranty responsibility of EIC shall immediately terminate.
EIC MAKES NO OTHER WARRANTY OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED; AND ALL WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED BY EIC AND EXCLUDED FROM THESE CONDITIONS. The Purchaser's sole and exclusive remedy, whether upon warranty, contract or tort, including negligence, will be to proceed under this warranty. All liability of EIC shall terminate no later than the expiration of the Warranty Period.