INTRODUCTION
Designed for a wide range of applications, the RM85 is a rugged, industrial unit, which utilizes an energy-efficient compressor and a compact portable design to provide easy efficient drying.
The RM85 has a number of special features:
High efficiency rotary compressor
EIPL’s “Hot Gas” defrost system
Hours run meter
Integral pump out system
Provision for permanent drainage
Extra long power cord
Robust rotational moulded polyethylene housing
Separate outlets allowing dry air to be ducted
The fan draws the moist air through the cold evaporator coil, which cools the air below its dew point. Moisture forms on the evaporator coil and is collected in the condensate tray, which is equipped with a permanent drain. The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase, plus the additional heat generated by the compressor. The air is, therefore, discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered. Continuous circulation of air through the dehumidifier gradually reduces the relative humidity within the area.
The RM85 dehumidifier is a rugged, reliable drying unit designed to operate effectively over a broad range of temperature and humidity conditions. An active hot gas defrost system, controlled by an electronic timer, guarantees positive de-icing, thereby optimizing operation at low temperatures.
The unit incorporates a rotational moulded polyethylene shell resilient to damage caused by rough handling.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid hazard.
Page 3 of 8
Drawing : - TPC406 Issue : - 3 Date : - 08/08/14
SPECIFICATIONS
"This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The
refrigeration system is hermetically sealed.
The Global Warming Potential (GWP) of refrigerants used in products manufactured by Ebac
Industrial Products Ltd is as follows
R134a – 1300 R407c – 1610
For type and weight of refrigerant contained in this unit, please refer to the product data label"
M
ODEL
:
10560RG-GB
H
EIGHT
: 945 mm
W
IDTH
: 545 mm
D
EPTH
: 492 mm
W
EIGHT
: 45 kg
A
IRFLOW
:
390 M3/Hr
P
OWER SUPPLY
: 230V/ 50Hz/ 1 ph
F
INISH
:
Rotational Moulded polyethylene
O
PERATING RANGE
: 3°C – 35°C
R
EFRIGERANT
: R407c (500g)