Eaton 5PX1500IRTN User Manual

5PX 1500i RT2U 5PX 2000i RT2U 5PX 2200i RT2U 5PX 3000i RT2U 5PX 3000i RT3U 5PX EBM 48V RT2U 5PX EBM 72V RT2U 5PX EBM 72V RT3U
ENGLISH
Installation and user manual
Copyright © 2010 EATON All rights reserved.
Call your local service representative
614-07977-00_EN
Page 2
614-07977-00_EN
Certication Standards
UPS directives:
Safety: IEC 62040-1: 2008 (C2) p EMC: IEC 62040-2: 2005 p Performance: IEC 62040-3: 2010 p
CE mark (EN 62040-1: 2008 and EN 62040-2: 2006 (C1))
Class B emission level CISPR 22: 2005 + A2 2006 (EN 55022) Harmonics emission: IEC 61000-3-2 edition 3.2: 2009 Flickers emission: IEC 61000-3-3 edition 2: 2008
The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the EC Declaration of Conformity, contact Eaton Power Quality or check Eaton website:
www.powerquality.eaton.com
Special Symbols
The following are examples of symbols used on the UPS or accessories to alert you to important information:
RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol.
Important instructions that must always be followed.
Do not discard the UPS or the UPS batteries in the trash. This product contains sealed lead acid batteries and must be disposed as it's explain in this manual. For more information, contact your local recycling/reuse or hazardous waste center.
This symbol indicates that you should not discard waste electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center.
Information, advice, help.
Page 3
614-07977-00_EN
ENGLISH
Contents
1. Introduction ....................................................................................... 4
1.1 Environmental protection.................................................................................................4
2. Presentation ...................................................................................... 5
2.1 Standard positions ...........................................................................................................5
2.2 Rear Panels ......................................................................................................................6
2.3 Control panel ...................................................................................................................7
2.4 LCD description ...............................................................................................................8
2.5 Display functions ............................................................................................................. 9
2.6 User settings ................................................................................................................... 9
3. Installation .......................................................................................11
3.1 Unpacking and contents check ...................................................................................... 11
3.2 Installation in tower position .......................................................................................... 12
3.3 Installation in rack position ............................................................................................12
3.4 Communication ports .................................................................................................... 13
3.5 Connection with a FlexPDU (Power Distribution Unit) module (optional) ...................... 14
3.6 Connection with a HotSwap MBP module (optional) ....................................................14
3.7 UPS connection without a FlexPDU or HotSwap MBP module ....................................15
4. Operation......................................................................................... 16
4.1 Start-up and Normal operation ....................................................................................... 16
4.2 Starting the UPS on Battery...........................................................................................16
4.3 UPS Shutdown .............................................................................................................. 16
4.4 Operation on Battery Power ..........................................................................................16
4.5 Return of AC Input Power ..............................................................................................17
4.6 UPS remote control functions ....................................................................................... 17
5. Maintenance.................................................................................... 18
5.1 Troubleshooting .............................................................................................................18
5.2 Battery-module replacement ......................................................................................... 19
5.3 Maintenance on a UPS equipped with the HotSwap MBP module ..............................20
6. Appendices ...................................................................................... 21
6.1 Technical specications .................................................................................................21
6.2 Glossary .........................................................................................................................22
Page 4
614-07977-00_EN
1. Introduction
01
PET
01
PET
Thank you for selecting an EATON product to protect your electrical equipment.
The 5PX range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features
of your UPS (Uninterruptible Power System).
Before installing 5PX, please read the booklet presenting the safety instructions. Then follow the indications in this manual.
To discover the entire range of EATON products and the options available for the 5PX range, we invite you to visit our web site at www.eaton.com or contact your EATON representative.
1.1 Environmental protection
EATON has implemented an environmental-protection policy. Products are developed according to an eco-design approach.
Substances
This product does not contain CFCs, HCFCs or asbestos.
Packing
To improve waste treatment and facilitate recycling, separate the various packing components.
The cardboard we use comprises over 50 % of recycled cardboard. p Sacks and bags are made of polyethylene. p
Packing materials are recyclable and bear the appropriate identication symbol p
Materials Abbreviations Number in
the symbols
Polyethylene terephthalat PET 01
High-density polyethylene HDPE 02
Polyvinyl chloride PVC 03
Low-density polyethylene LDPE 04
Polypropylene PP 05
Polystyrene PS 06
Follow all local regulations for the disposal of packing materials.
End of life
EATON will process products at the end of their service life in compliance with local regulations. EATON works with companies in charge of collecting and eliminating our products at the end of
their service life.
Product
The product is made up of recyclable materials. Dismantling and destruction must take place in compliance with all local regulations concerning waste. At the end of its service life, the product must be transported to a processing centre for electrical and
electronic waste.
Battery
The product contains lead-acid batteries that must be processed according to applicable local regulations concerning batteries.
The battery may be removed to comply with regulations and in view of correct disposal.
Page 5
614-07977-00_EN
ENGLISH
2. Presentation
D
W
H
D
W
H
D
H
W
D
H
W
2.1 Standard positions
Tower position
Rack position
Description Weights (kg/lb) Dimensions (mm/inch)
D x W x H
5PX 1500i RT2U 27.60 / 60.90 522 x 441.2 x 86.2 / 20.6 x 17.4 x 3.4 5PX 2000i RT2U 28.50 / 62.80 5PX 2200i RT2U 28.50 / 62.80 5PX 3000i RT2U 38.08 / 84.00 647 x 441.2 x 86.2 / 25.5 x 17.4 x 3.4 5PX 3000i RT3U 37.33 / 82.30 497 x 441.2 x 130.7 / 19.6 x 17.4 x 5.1 5PX EBM 48V RT2U 32.80 / 72.30 522 x 441.2 x 86.2 / 20.6 x 17.4 x 3.4 5PX EBM 72V RT2U 46.39 / 102.30 647 x 441.2 x 86.2 / 25.5 x 17.4 x 3.4 5PX EBM 72V RT3U 44.26 / 97.60 497 x 441.2 x 130.7 / 19.6 x 17.4 x 5.1
Page 6
614-07977-00_EN
2. Presentation
2.2 Rear Panels
5PX 1500i / 2000i
5PX 2200i
5PX 3000i
(1) USB communication port (2) RS232 communication port (3) Connector for automatic recognition
of optional battery modules
(4) Slot for optional communication card (5) Connector for ROO (remote ON/OFF)
or RPO (Remote Power Off) control
(6) Connector for optional battery
modules
(7) 16 A outlet for connection of
equipment (Primary group)
(8) Two groups of 2 programmable
outlets for connection of equipment (Group 1 and 2)
(9) Groups of 4 outlets for connection of
equipment (Primary group)
(10) Socket for connection to AC-power
source
5PX EBM (optional battery module)
(12) Connectors for battery modules
(to the UPS or to the other battery modules)
(13) Connectors for automatic recognition
of battery modules
Page 7
614-07977-00_EN
ENGLISH
2. Presentation
Normal mode
100% 17min 1EBM
100%
2.7kW 3kVA
Efficiency: 98%
2.3 Control panel
The UPS has a ve-button graphical LCD. It provides useful information about the UPS itself, load status,
events, measurements and settings.
Power On
Indicator (green)
On battery
Indicator (yellow)
Alarm
Indicator (red)
Escape Up Down Enter On/Off
button
The following table shows the indicator status and description :
Indicator Status Description
Green
Yellow
Red
On The UPS is operating normally
On The UPS is on battery mode
Flashing The battery voltage is below the warning level
On
The UPS has an active alarm or fault. See trouble­shooting on page 18 for additional information.
Loading...
+ 15 hidden pages