Eaton 5P 1500 RT, 5P 2200 RT, 5P 2200, 5P 3000 RT, 5P 3000 User Manual

ENGLISH
5P 1500 RT 5P 2200 RT 5P 2200 5P 3000 RT 5P 3000
Installation and user manual
Copyright © 2012 EATON All rights reserved.
Service and support:
Call your local service representative
614-03898-00_EN
Page 2
614-03898-00_EN
Page 3
614-03898-00_EN
ENGLISH
Special Symbols
The following are examples of symbols used on the UPS or accessories to alert you to important information:
RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol.
Important instructions that must always be followed.
Do not discard the UPS or the UPS batteries in the trash. This product contains sealed lead acid batteries and must be disposed as it's explain in this manual. For more information, contact your local recycling/reuse or hazardous waste center.
This symbol indicates that you should not discard waste electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center.
Information, advice, help.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS. This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries.
The 5P models that are covered in this manual are intended for installation in an environment within 0 to 40°C, free of conductive contaminant.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Certication Standards
UPS directives: UL 1778 4 p
th
edition (UL listed).
Performance: IEC 62040-3: 2001. p Radiated emission: FCC CFR 47 part 15 subpart B, Class A. p Surges withstand ability: IEEE ANSI C62.41 Category A2 (UL Listed). p
Page 4
614-03898-00_EN
Safety of Persons
The system has its own power source (the battery). Consequently, the power outlets may be energized p even if the systems is disconnected from the AC power source.
Dangerous voltage levels are present within the system. It should be opened exclusively by qualied p service personnel.
The system must be properly grounded. p The battery supplied with the system contains small amounts of toxic materials. p
To avoid accidents, the directives listed below must be observed:
- servicing of batteries should be performed or supervised by personnel knowledgeable about betteries and the required precautions.
- when replacing batteries, replace with the same type and number of batteries or battery packs.
- do not dispose of batteries in a re. The batteries may explode.
- batteries constitute a danger (electrical shock, burns). The short-circuit current may be very high.
Precautions must be taken for all handling:
Wear rubber gloves and boots. p Do not lay tools or metal parts on top of batteries. p Disconnect charging source prior to connecting or disconnecting battery terminals. p Determine if battery is inadvertently grounded. If inadvertently grounded, remove source from ground. p
Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance (applicable to equipment and remote battery supplies not having a grounded supply circuit).
Product Safety
The UPS connection instructions and operation described in the manual must be followed in p the indicated order.
A protection circuit breaker must be installed upstream and be easily accessible. p The system can be disconnected from the AC power source by opening this circuit breaker.
Check that the indications on the rating plate correspond to your AC powered system and to p the actual electrical consumption of all the equipment to be connected to the system.
For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall p be easily accessible
Never install the system near liquids or in an excessively damp environment. p Never let a foreign body penetrate inside the system. p Never block the ventilation grates of the system. p Never expose the system to direct sunlight or source of heat. p If the system must be stored prior to installation, storage must be in a dry place. p The admissible storage temperature range is -15 ºC to +50 ºC. p
Special Precautions
All handling operations will require at least two people (unpacking, installation in rack system). p Before and after the installation, if the UPS remains de-energized for a long period, the UPS must be p
energized for a period of 24 hours, at least once every 6 months (for a normal storage temperature less than 25 °C). This charges the battery, thus avoiding possible irreversible damage.
During the replacement of the Battery Module, it is imperative to use the same type and number of p element as the original Battery Module provided with the UPS to maintain an identical level of performance and safety. In case of doubt, don’t hesitate to contact your EATON representative.
Page 5
614-03898-00_EN
ENGLISH
Contents
1. Introduction ....................................................................................... 6
1.1 Environmental protection.................................................................................................6
2. Presentation ...................................................................................... 7
2.1 Standard installations .......................................................................................................7
2.2 Rear Panels ......................................................................................................................8
2.3 Control panel ...................................................................................................................9
2.4 LCD description ............................................................................................................. 10
2.5 Display functions ........................................................................................................... 11
2.6 User settings ................................................................................................................. 11
3. Installation ...................................................................................... 13
3.1 Unpacking and contents check ...................................................................................... 13
3.2 Battery module connection............................................................................................14
3.3 Tower installation ........................................................................................................... 15
3.4 Rack installation (RT only) .............................................................................................. 15
3.5 Communication ports .................................................................................................... 16
3.6 Connection with a FlexPDU (Power Distribution Unit) module (optional) ...................... 17
3.7 Connection with a HotSwap MBP module (optional) ....................................................17
3.8 UPS connection without a FlexPDU or HotSwap MBP module ....................................18
4. Operation......................................................................................... 19
4.1 Start-up and Normal operation ....................................................................................... 19
4.2 Starting the UPS on Battery...........................................................................................19
4.3 UPS Shutdown .............................................................................................................. 19
4.4 Operation on Battery Power ..........................................................................................19
4.5 Return of AC Input Power ..............................................................................................20
4.6 UPS remote control functions ....................................................................................... 20
5. Maintenance.................................................................................... 21
5.1 Troubleshooting .............................................................................................................21
5.2 Battery-module replacement .........................................................................................22
5.3 Maintenance on a UPS equipped with the HotSwap MBP module ..............................23
6. Appendices ...................................................................................... 24
6.1 Technicalspecications .................................................................................................24
6.2 Glossary ......................................................................................................................... 25
Page 6
614-03898-00_EN
1. Introduction
Thank you for selecting an EATON product to protect your electrical equipment.
The 5P range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features
of your UPS (Uninterruptible Power System).
Before installing your 5P, please read the booklet presenting the safety instructions. Then follow the indications in this manual.
To discover the entire range of EATON products and the options available for the 5P range, we invite you to visit our web site at www.eaton.com/powerquality or contact your EATON representative.
1.1 Environmental protection
EATON has implemented an environmental-protection policy. Products are developed according to an eco-design approach.
Substances
This product does not contain CFCs, HCFCs or asbestos.
Packing
To improve waste treatment and facilitate recycling, separate the various packing components.
The cardboard we use comprises over 50% of recycled cardboard. p Sacks and bags are made of polyethylene. p
Packing materials are recyclable and bear the appropriate identication symbol p
01
PET
Materials Abbreviations Number in
the symbols
Polyethylene terephthalat PET 01
High-density polyethylene HDPE 02
Polyvinyl chloride PVC 03
Low-density polyethylene LDPE 04
Polypropylene PP 05
Polystyrene PS 06
Follow all local regulations for the disposal of packing materials.
End of life
EATON will process products at the end of their service life in compliance with local regulations. EATON works with companies in charge of collecting and eliminating our products at the end of
their service life.
Product
The product is made up of recyclable materials. Dismantling and destruction must take place in compliance with all local regulations concerning waste. At the end of its service life, the product must be transported to a processing center for electrical and
electronic waste.
Battery
The product contains lead-acid batteries that must be processed according to applicable local regulations concerning batteries.
The battery may be removed to comply with regulations and in view of correct disposal.
01
PET
Page 7
614-03898-00_EN
ENGLISH
2. Presentation
2.1 Standard installations
Tower installation
D
W
H
Rack installation
D
H
W
Description Weights
(lb/kg)
Dimensions (inch/mm) D x W x H
5P 1500 RT 58.60 / 26.60 20.6 x 17.4 x 3.4 / 522 x 441.2 x 86.2 5P 2200 RT 60.20 / 27.30 5P 2200 5P 3000 RT 81.10 / 36.80 25.5 x 17.4 x 3.4 / 647 x 441.2 x 86.2 5P 3000
Page 8
614-03898-00_EN
2. Presentation
2.2 Rear panels
5P 1500
8a
8b
5P 2200
8a
8b
5P 3000
11
8a
8b
1
USB communication port
2
RS232 communication port
3
Not used, connector for automatic
recognition of an additional battery module
4
Slot for optional communication card
5
Connector for ROO (remote ON/OFF)
or RPO (Remote Power OFF) control
7
30A outlet (L5-30R) for connection of
equipment (for 5P 3000 only)
8a
Group 1: 2 programmable outlets for
connection of equipment
8b
Group 2: 2 programmable outlets for
connection of equipment
9
Primary Group: outlets for
connection of critical equipment
10
Attached 8 ft. input power cord for
AC-power source 5-15P for 1000 / 1500 5-20P for 2200 L5-30P for 3000
11
LED indicating site wiring fault (SWF)
alarm