Certication Standards
UPS directives:
• Safety: IEC 62040-1: 2008 (C2)
• EMC: IEC 62040-2: 2005, VCCI
• Performance: IEC 62040-3: 2010
CE mark (EN 62040-1: 2008 and EN 62040-2: 2006 (C1))
Class B emission level CISPR 22: 2005 + A2 2006 (EN 55022) Harmonics emission: IEC 61000-3-2 edition 3.2: 2009 Flickers emission: IEC 61000-3-3 edition 2: 2008
VCCI Notice
The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the EC Declaration of Conformity, contact Eaton Power Quality or check Eaton website:
www.powerquality.eaton.com
Special Symbols
The following are examples of symbols used on the UPS or accessories to alert you to important information:
RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol.
Important instructions that must always be followed.
Do not discard the UPS or the UPS batteries in the trash. This product contains sealed lead acid batteries and must be disposed as it's explain in this manual. For more information, contact your local recycling/reuse or hazardous waste center.
This symbol indicates that you should not discard waste electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center.
Page 2
Information, advice, help.
620-00082-02-i (en)
Contents
1. Introduction ....................................................................................... 4
1.1 Environmental protection ...................................................................................................4
2. Presentation ...................................................................................... 5
2.1 Standard installations ......................................................................................................... 5
2.2 Tower rear panels ..............................................................................................................6
2.3 Rack rear panels ................................................................................................................7
2.4 Control panel .....................................................................................................................8
2.5 LCD description ................................................................................................................. 9
2.6 Display functions ............................................................................................................. 10
2.7 User settings ................................................................................................................... 10
3. Installation ...................................................................................... 12
3.1 Unpacking and contents check ........................................................................................ 12
3.2 Installation of tower models ............................................................................................13
3.3 Wall installation of rack models (650i R / 850i R / 1150i R) ..............................................13
3.4 Installation of rack models (650i R only) .......................................................................... 14
3.5 Installation of rack models (850i R / 1150i R / 1550i R) .................................................... 14
3.6 Communication ports ...................................................................................................... 15
ENGLISH
4. Operation......................................................................................... 16
4.1 Start-up and Normal operation ......................................................................................... 16
4.2 Starting the UPS on Battery ............................................................................................16
4.3 UPS Shutdown ................................................................................................................16
4.4 Operation on Battery Power ............................................................................................16
4.5 Return of AC Input Power ................................................................................................ 17
4.6 UPS remote control functions ......................................................................................... 17
5. Maintenance ................................................................................... 18
5.1 Troubleshooting ................................................................................................................ 18
5.2 Battery-module replacement ...........................................................................................19
6. Appendices ...................................................................................... 21
6.1 Technical specications ....................................................................................................21
620-00082-02-i (en)
Page 3
1. Introduction
Thank you for selecting an EATON product to protect your electrical equipment.
The 5P range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features
of your UPS (Uninterruptible Power System).
Before installing 5P, please read the booklet presenting the safety instructions. Then follow the instructions in this manual.
To discover the entire range of EATON products and the options available for the 5P range, we invite you to visit our web site at www.eaton.com/powerquality or contact your EATON representative.
1.1 Environmental protection
EATON has implemented an environmental-protection policy. Products are developed according to an eco-design approach.
Substances
This product does not contain CFCs, HCFCs or asbestos.
Packing
To improve waste treatment and facilitate recycling, separate the various packing components.
• The cardboard we use comprises over 50 % of recycled cardboard.
• Sacks and bags are made of polyethylene.
• Packingmaterialsarerecyclableandbeartheappropriateidenticationsymbol
Materials Abbreviations Number in
the symbols
01
PET
01
PET
Polyethylene terephthalat PET 01
High-density polyethylene HDPE 02
Polyvinyl chloride PVC 03
Low-density polyethylene LDPE 04
Polypropylene PP 05
Polystyrene PS 06
Follow all local regulations for the disposal of packing materials.
End of life
EATON will process products at the end of their service life in compliance with local regulations. EATON works with companies in charge of collecting and eliminating our products at the end of
their service life.
Page 4
Product
The product is made up of recyclable materials. Dismantling and destruction must take place in compliance with all local regulations concerning waste. At the end of its service life, the product must be transported to a processing centre for electrical and
electronic waste.
Battery
The product contains lead-acid batteries that must be processed according to applicable local regulations concerning batteries.
The battery may be removed to comply with regulations and in view of correct disposal.
620-00082-02-i (en)
2. Presentation
2.1 Standard installations
Tower models
D
H
W
Description Weights (kg/lb) Dimensions (mm/inch)
D x W x H
5P 650i 7.52 / 16.60 345 x 150 x 233 / 13.6 x 5.9 x 9.2 5P 850i 9.93 / 21.90 345 x 150 x 233 / 13.6 x 5.9 x 9.2 5P 1150i 10.91 / 24.10 345 x 150 x 233 / 13.6 x 5.9 x 9.2 5P 1550i 15.95 / 35.20 445 x 150 x 233 / 17.5 x 5.9 x 9.2
ENGLISH
Rack models
D
H
W
Description Weights (kg/lb) Dimensions (mm/inch)
D x W x H
5P 650i R 8.6 / 19.00 363.5 x 438 x 43.2 / 14.3 x 17.2 x 1.7 5P 850i R 13.8 / 30.40 509 x 438 x 43.2 / 20.0 x 17.2 x 1.7 5P 1150i R 14.64 / 32.70 509 x 438 x 43.2 / 20.0 x 17.2 x 1.7 5P 1550i R 19.36 / 42.70 554 x 438 x 43.2 / 21.8 x 17.2 x 1.7
620-00082-02-i (en)
Page 5
2. Presentation
2.2 Tower rear panels
5P 650i
5
6a
6b
7
5P 850i
5
6b
7
6a
(1) USB communication port (2) RS232 communication port (3) Slot for optional communication card
3
2
(4) Connector for ROO (remote ON/OFF)
or RPO (Remote Power Off) control
(5) Outlets for connection of critical
equipment (Primary group)
1
4
8
(6a) Group 1: programmable outlets for
connection of equipment
(6b) Group 2: programmable outlets for
connection of equipment
(7) Socket for connection to AC-power
source
(8) Ground screw
3
2
1
4
8
5P 1150i
5
6b
7
5P 1550i
5
6b
6a
3
2
1
4
8
6a
3
2
1
4
8
7
Page 6
620-00082-02-i (en)
2. Presentation
2.3 Rack rear panels
5P 650i R / 5P 850i R
2 1 4 87 36a 6b5
5P 1150i R
2 1 47 36b58
5P 1550i R
6a
ENGLISH
(1) USB communication port (2) RS232 communication port (3) Slot for optional communication card (4) Connector for ROO (remote ON/OFF)
or RPO (Remote Power Off) control
(5) Outlets for connection equipment
(Primary group)
(6a) Group 1: programmable outlets for
connection of equipment
(6b) Group 2: programmable outlets for
connection of equipment
(7) Socket for connection to AC-power
source
(8) Ground screw
2 1 473 6b
5
8
6a
620-00082-02-i (en)
Page 7