Eagle SSC Installation Manual

Page 1
Installation Instructions for the
ISSUE 4
TruStability
HSC Series and SSC Series
50044171
Silicon Pressure Sensors, Digital Output
GENERAL INFORMATION
TruStability Standard Accuracy Silicon Ceramic (SSC) Series are piezoresistive silicon pressure sensors offering a digital output for reading pressure over the specified full scale pressure span and temperature range. They are available in standard pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar) and are intended for use with non-corrosive, non-ionic gases, such as air and other dry gases. The liquid media option extends the performance of these sensors to con-corrosive, non-ionic liquids.
LIQUID MEDIA OPTION
®
High Accuracy Silicon Ceramic (HSC) Series and
CAUTION
PRODUCT DAMAGE
Ensure liquid media is applied to Port 1 only; Port 2 is not
compatible with liquids.
Ensure liquid media contains no particulates. All
TruStability can accumulate inside the sensor, causing damage or affecting sensor output.
Recommend that the sensor be positioned with Port 1
facing downwards; any particulates in the system are less likely to enter and settle within the pressure sensor if it is in this position.
Ensure liquid media does not create a residue when dried;
build-up inside the sensor may affect sensor output. Rinsing of a dead-ended sensor is difficult and has limited effectiveness for removing residue.
Ensure liquid media are compatible with wetted materials.
Non-compatible liquid media will degrade sensor performance and may lead to sensor failure.
Failure to comply with these instructions may result in product damage.
Table 2. Absolute Maximum Ratings
Parameter Min. Max. Unit
Supply voltage -0.3 6.0 V Voltage on output pin -0.3 Vsupply + 0.3 V ESD susceptibility (human body model) 3 - kV Storage temperature range -40 [-40] 85 [185] °C [°F] Soldering times and temperature:
Lead solder (SIP, DIP) Peak reflow (SMT)
®
sensors are dead-ended devices. Particulates
2
SOLDERING
See soldering times and temperatures in Table 2.
CLEANING
CAUTION
IMPROPER CLEANING
Ensure cleaning fluids, such as appropriate alcohols or
fluorinated solvents, are used based on the type of contaminants to be removed.
Do not immerse the sensor.
Failure to comply with these instructions may result in product damage.
Table 1. Environmental Specifications
Parameter Characteristic
Humidity:
Dry gases only Liquid media option
Vibration MIL-STD-202F, Curve AK (20.7 g
Shock MIL-STD-202F, Method 213B,
Life1 1 million cycles minimum Solder reflow J-STD-020-C
4 s max. at 250 °C [482 °F]
15 s max. at 250 °C [482 °F]
0% to 95% RH, non-condensing 100% condensing or direct liquid media on Port 1
random)
Condition F
Sensing and Control
Page 2
TruStability HSC Series and SSC
y
y
Issue 4 50044171
Series, Digital Output
Table 3. Operating Specifications
Parameter Min. Typ. Max. Unit
Supply voltage (Vsupply)3:
3.3 Vdc
5.0 Vdc
3.0
4.75
3.3
5.0
4
4
Supply current:
3.3 Vdc supply
5.0 Vdc suppl
-
-
1.6 2
Compensated temperature range5: HSC Series SSC Series
0 [32]
-20 [-4]
-
­Operating temperature range6: HSC Series SSC Series Accurac
7
- - ±0.25 %FSS BFSL
-20 [-4]
-40 [-40]
-
-
Response time - 0.46 - ms Resolution 12 - - bits Total error band8: HSC Series SSC Series
-
-
-
­Bus standards I2C, fast mode (400 kHz) Serial Peripheral Interface (SPI)
Table 4. Wetted Materials
10
Parameter Port 1 (Pressure Port) Port 2 (Reference Port)
Covers high temperature polyamide high temperature polyamide Substrate alumina ceramic alumina ceramic Adhesives epoxy, silicone epoxy, silicone Electronic components ceramic, glass, solder, silicon silicon, glass, gold, solder
Notes:
1. Life may vary depending on specific application in which the sensor is utilized.
2. Absolute maximum ratings are the extreme limits the device will withstand without damage.
3. Ratiometricity of the sensor (the ability of the digital device to maintain performance parameters independent of supply voltage) is achieved
within the specified operating voltage for each option. Other custom supply voltages are available, please contact Honeywell Customer Service.
4. The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
5. The compensated temperature range is the temperature range over which the sensor will produce an output proportional to pressure within
the specified performance limits.
6. The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not
remain within the specified performance limits.
7. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at
25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.
8. Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range.
Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis.
9. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of
the pressure range. (See figure 1 for ranges).
10. Contact Honeywell Customer Service for detailed material information.
Table 5. Pinouts for SMT and DIP Packages
Output Type Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8
I2C GND Vsupply SDA SCL NC NC NC NC
SPI GND Vsupply MISO SCLK SS NC NC NC
Table 6. Pinouts for SIP Package
Output Type Pin 1 Pin 2 Pin 3 Pin 4
I2C GND Vsupply SDA SCL
3.6
5.25
2.1 3
50 [122] 85 [185]
85 [185] 85 [185]
±1 ±2
Vdc
mA
°C [°F]
°C [°F]
%FSS
9
2 Honeywell Sensing and Control
Page 3
TruStability HSC Series and SSC Series, Digital Output
Figure 1. DIP Pressure Port Dimensional Drawings (For reference only: mm [in])
DIP NN: No ports
8 7 6 5
5,44
[0.214]
0,25
[0.010]
10,0
[0.39]
DIP AN: Single axial barbed port
Issue 4 50044171
13,35
[0.525]
1 2 3 4
2,54 TYP.
[0.100]
8X 0,46
[0.018]
PORT 1 PORT 2
9,24
[0.364]
10,85
[0.427]
6,99
[0.275]
DIP LN: Single axial barbless port DIP RN: Single radial barbed port
DIP RR: Dual radial barbed ports, same side
PORT 1
PORT 2
3,78
[0.149]
4,0
[0.16]
8 7 6 5
1 2 3 4
2,54 TYP.
[0.100]
8X 0,46
[0.018]
PORT 1
6,16
[0.242]
11,21
[0.441]
9,24
[0.364]
PORT 2
,25
[0.010]
13,35
[0.525]
6,99
[0.275]
10,0
[0.39]
2X 1,93 DIA.
[0.076]
4,65
[0.183]
DIP DR: Dual radial barbed ports, opposite sides
9,24
[0.364]
PORT 2
0,25
[0.010]
6,99
[0.275]
PORT 2
15,76
[0.620]
8 7 6 5
1 2 3 4
2,54 TYP.
[0.100]
8X 0,46
[0.018]
2X 1,93 DIA.
[0.076]
PORT 1
3,78
[0.149]
PORT 1
6,16
[0.242]
11,21
[0.441]
Honeywell Sensing and Control 3
10,0
[0.39]
13,35
[0.525]
Page 4
TruStability HSC Series and SSC Series, Digital Output
Figure 2. SMT Pressure Port Dimensional Drawings (For reference only: mm [in])
SMT NN: No ports
SMT AN: Single axial barbed port
Issue 4 50044171
SMT LN: Single axial barbless port
SMT RR: Dual radial barbed ports, same side
SMT RN: Single radial barbed port
SMT DR: Dual radial barbed ports, opposite sides
4 Honeywell Sensing and Control
Page 5
TruStability HSC Series and SSC Series, Digital Output
Figure 3. SIP Package Dimensional Drawings (For reference only: mm [in])
SIP NN: No ports
SIP AA: Dual axial barbed ports, opposite sides
Issue 4 50044171
SIP AN: Single axial barbed port SIP LN: Single barbless port
SIP FF: Fastener mount, dual axial barbed ports, opposite sides
SIP FN: Fastener mount, single axial barbed port
Honeywell Sensing and Control 5
Page 6
TruStability HSC Series and SSC Series, Digital Output
Figure 3. SIP Package Dimensional Drawings (continued)
SIP GN: Ribbed fastener mount, single axial barbed port
SIP NB: Fastener mount, dual axial ports, same side
27,96
[1.101]
21,60
[0.850]
4X 0,51
[0.020]
2X 3,94 DIA.
[0.155]
PORT 2
[0.010]
0,25
16,51
[0.650]
PORT 1
4.78 DIA. [0.188]
Issue 4 50044171
19,06
[0.750]
10,63
1 2 3 4
2,54 TYP.
[0.100]
[0.418]
SIP RN: Single radial barbed port
SIP RR: Dual radial barbed ports, same side
6 Honeywell Sensing and Control
Page 7
TruStability HSC Series and SSC Series, Digital Output
Figure 3. SIP Package Dimensional Drawings (continued)
SIP DR: Dual radial barbed ports, opposite side
SIP HH: Fastener mount, dual radial barbed ports, same side
Issue 4 50044171
SIP HN: Fastener mount, single radial barbed port SIP MN: Manifold mount, outer diameter seal
SIP SN: Manifold mount, inner diameter seal
Honeywell Sensing and Control 7
Page 8
TruStability HSC Series and SSC Series, Digital Output
Issue 4 50044171
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com/sensing
50044171-4-EN IL50 GLO Printed in USA March 2011 Copyright © 2011 Honeywell International Inc. All rights reserved.