Eagle DCS302 User Manual

DCS302
DUAL CYLINDER SCALE
INSTALLATION & OPERATION
MANUAL
Eagle Microsystems, Inc. 366 Circle of Progress Pottstown, PA 19464
www.eaglemicrosystems.com
phone 610-323-2250 : fax 610-323-0114
DCS302 GENERAL INFORMATION
The DCS302 is a dual cylinder scale designed specifically for the water and wastewater industry. The scale base and weighing surfaces are made of Type 2 PVC plastic and are guaranteed for five years against environmental damage. All mechanical parts, wherever possible, are made of stainless steel or protected with a durable chemical-resistant powder finish.
The DCS302 can accommodate any cylinder that does not exceed 12” diameter and 150 lbs. net weight.
SPECIFICATIONS
Accuracy: …….………………………………………………………… +/- 0.25% FS Resolution: …………………………………………………………….. 0.5 lb. Scale Readability: ……………………………………………………… 0.1 lb. Scale capacity: ..………………………………………………………. 300 lbs. Safe overload capacity: ……………………………………………….. 400 lbs.
FEATURES
Simultaneously weighs two cylinders independently and displays the net weight
on separate digital indicators.
• Wall mounting bracket and safety chains are optionally available. These can adapt to different cylinder sizes.
• All scales are factory assembled, tested and calibrated.
ASSEMBLY
The DCS302 scale base is fully assembled at the factory. Installation and testing procedures later in this manual.
OPERATION
See Instruction Manual EI-2000 for scale setup and operation.
WARRANTY
Eagle Microsystems warrants the DCS302 scale base to be free from all defects in material and workmanship. Any parts that fail because of defective Workmanship or material within five (5) years of date of shipment will be replaced. The warranty does not include miss use, negligence or modifications. Eagle Microsystems shall not be liable for transportation or installation charges, or any other expenses incurred by the customer.
INSTRUCTIONS
DCS302 DUAL CYLINDER LOAD CELL SCALE
1. Before placing scale in operation remove the six (6) plastic stops and the aluminum shipping plate located on the underside of the scale.
2. Determine service location of scale and position base 2 1/2-inches or more from the wall.
3. Anchor scale base securely to smooth, level floor using 3/8-inch anchor bolts (not supplied) through the four (4) 1/2-inch diameter holes in the corners of the scale base. It is recommended that the floor be level to within 0.5 degree for optimal performance.
4. Mount NEMA 4X EI-2000 Dual Channel Digital Display Instrument to a suitable and convenient wall surface. Remove instrument cover and mount instrument to the wall with #10 screws or suitably sized masonry or hollow wall anchors, as applicable. The instrument case has four (4) through holes, as shown in the Operating Manual, located on 5 3/8-inch centers horizontally and 5 5/8-inch centers vertically.
5. Route the cable provided, and factory terminated at the scale, to the display instrument. Make wiring connections as shown on pages 13 and 14 of the "EI-2000 Dual Channel Weight & Level Display/Transmitter Operating Manual" for the "DCS302 Dual Cylinder Scale".
6. Follow instructions in the Operating Manual for startup and calibration of the EI-2000. The scale base is factory calibrated using known weights and is ready for use when received.