1.00 in
[25 mm]
1.30
[33mm]
2 (Y) AXIS
1 (X) AXIS
ACTUAL SIZE
CONNECTOR MATES
WITH DYTRAN CABLE
6811AXX
3
.52 in
[13 mm]
MOUNTING SURFACE
5. MOUNTING SCREW: #8 OR M4
4. WEIGHT: 28 GRAMS
XX = CABLE LENGTH IN FEET
3
2. + SIGNS INDICATE SENSITIVE AXIS
AND DIRECTION OF INPUT
ACCELERATION FOR POSITIVE GOING
OUTPUT SIGNAL.
1. HOUSING MATERIAL: TITANIUM ALLOY
PIN 4
SIG / PWR AXIS 1 (X)
PIN 3
SIG / PWR AXIS 3 (Z)
EXCEPT AS OTHERWISE NOTED
ALL DIMENSIONS IN INCHES
TOLERANCE: XXX = .XX =
SURFACE FINISH
EXCEPT AS NOTED
BREAK EDGES TO DEBURR
RADIUS OR CHAMFER
THESE DIAS TO T.I.R
FILLETS: MAX R
3 (Z) AXIS
SCALE
.01
DATE
DRAWN
APPROVED
TITLE
DYTRAN
INSTRUMENTS, INC.
DATE
A
-
MODEL 3233A
REV
PART NO.
MATERIAL
NEXT ASSEMBLY
2:1
10/25/2003
CHECKED
PML
OUTLINE / INSTALLATION DRAWING
MODEL 3233A
PIN 1
GND RETURN, COMMON
PIN 2
SIG / PWR AXIS 2 (Y)
CHATSWORTH, CA
ECN
-
USED ON
DWG NO.
3233A
127-3233A
SHEET OF
1
1

SPECIFICATIONS, MODEL 3233A TRIAXIAL ACCELEROMETER
SPECIFICATIONS VALUE UNITS
PHYSICAL
WEIGHT 28 grams
SIZE (HEIGHT x WIDTH x DEPTH) 1.0 x 1.3 x .52 inches
(33 x 25 x 13) mm
MOUNTING 8-32 or M4 Screw
CONNECTOR 4-PIN [1]
MATERIAL, CASE/CONNECTOR TITANIUM ALLOY
PERFORMANCE
SENSITIVITY, ±10 % [2] 1000 mV/g
RANGE, FULL SCALE (each axis) ± 5 g pk
FREQUENCY RESPONSE, (axis 1 & 2) ± 10% .4 to 3000 Hz
(axis 3) ± 10% .4 to 6000 Hz
ELEMENT NATURAL FREQUENCY, NOM. 20 kHz
EQUIVALENT ELECTRICAL NOISE .0001 g rms
LINEARITY [3] 1 %F.S.
TRANSVERSE SENSITIVITY, MAX, 5 %
SIGNAL POLARITY POSITIVE FOR ACCELERATION
IN DIRECTION OF ARROWS ON CASE
ENVIRONMENTAL
MAXIMUM VIBRATION ± 500 g
MAXIMUM SHOCK 5000 g
TEMPERATURE RANGE -60 to +200 °F
ENVIRONMENTAL SEAL HERMETIC
COEFFICIENT OF THERMAL SENSITIVITY .03 %/°F
ENVIRONMENTAL
SUPPLY CURRENT RANGE, (each axis) [4] 2 to 20 mA
COMPLIANCE (SUPPLY) VOLTAGE RANGE (each axis) +18 to +30 VDC
OUTPUT IMPEDANCE, TYP. 100 OHMS
OUTPUT BIAS VOLTAGE +11 to +13 VDC
DISCHARGE TIME CONSTANT, NOM. 1 SEC
GROUND ISOLATION CASE GROUNDED TO SIGNAL GROUND
CASE ISOLATED FROM MOUNTING SURFACE
[1] Connector mates with Dytran cable assy. Model 6811Axx. (xx = length in feet)
[2] Reference sensitivity measured at 100 Hz, 1 g rms per ISA RP 37.2
[3] Linearity is % of specified full scale (or any lesser full scale range), zero-based best-fit straight-line method.
[4] Power only with Dytran LIVM power unit or other Dytran-compatible constant current type power unit. If power
is applied without current limiting protection, the internal amplifier will be immediately destroyed.
Rev B, ECN 7231, 11/24/10
2