DYNEX MF70-1200, MF70-1400, MF70-1600 Datasheet

MF70
MF70
Fast Recovery Diode
Advance Information
Replaces March 1998 version, DS4195-2.1 DS1955-3.0 January 2000
APPLICATIONS
Inverse Parallel Or Series Connected Diode
Power Supplies
High Frequency Applications
FEATURES
Glass Passivation
High Voltage Capabilities
VOLTAGE RATINGS
Type Number Repetitive Peak
Reverse Voltage
V
RRM
V
MF70-1600 MF70-1400 MF70-1200
1600 1400 1200
Conditions
V
= V
RSM
RRM
+ 100V
KEY PARAMETERS
V I
F(AV)
I
FSM
Q t
rr
RRM
r
1600V
70A
700A 26µC
915ns
Lower voltage grades available. For stud anode add suffix 'R' to type number.
See Package Details for further information.
Outline type code: DO5.
CURRENT RATINGS
Symbol Parameter Conditions UnitsMax.
I
F(AV)
I
F(RMS)
I
Mean forward current
RMS value
F
Continuous (direct) forward current
Half wave resistive load, T
= 75oC 110 A
T
case
T
= 75oC90A
case
= 75oC70A
case
1/8
MF70
SURGE RATINGS
ParameterSymbol
FSM
Surge (non-repetitive) forward currentI
THERMAL AND MECHANICAL DATA
Symbol
th(j-c)
th(c-h)
T
stg
Thermal resistance - junction to caseR
Thermal resistance - case to heatsinkR
Virtual junction temperature
vj
- Mounting torque
Parameter
Conditions
10ms half sine; with 100% V
10ms half sine;
= 125oC
Tj
Conditions Max. Units
dc
RRM, Tj
= 125oC
Max. Units
700 A
2450 A
Min.
- 0.37oC/W
Mounting torque 3.5Nm with mounting compound
Forward (conducting) - 125 Reverse (blocking)
- 125
125-55Storage temperature rangeT
Use torque wrench
3.83.2
o
C/W- 0.2
Nm
o
o
˚C
2
sI2t for fusingI2t
C C
CHARACTERISTICS
Symbol Typ. Units
V
FM
I
RM
t
rr
Q
t
rr
V
TO
r
T
V
FRM
Forward voltage
Peak reverse current Reverse recovery time
Recovered charge
r
Reverse recovery time
Threshold voltage
Slope resistance
Forward recovery voltage di/dt = 1000A/µs, Tj = 125oC80-V
Parameter
Conditions Max.
At 210A peak, T At V
, T
RRM
case
IF = 1A, diRR/dt = 25A/µs T
= 25oC, VR = 100V
case
I
= 100A, diRR/dt = 100A/µs
F
T
= 25oC, VR = 100V
case
= 25oC - 2.0 V
case
= 100oC-mA
10
- 300
-26µC
- 915 ns
At Tvj = 125oC - 1.3 V
At Tvj = 125oC - 3.34 m
ns
2/8
CURVES
500
Measured under pulse
conditions
400
80
T
case
MF70
= 25˚C
60
95%
300
40
5%
200
20
Instantaneous forward current - (A)
100
Tj = 125˚C
Tj = 25˚C
0
Transient forward voltage - (V)
0
0 400 800 1200
200 600 1000
Rate of rise of forward current - (A/µs)
0 1.0 2.0 3.0
Instantaneous forward voltage - (V)
Fig.1 Maximum (limit) forward characteristics Fig.2 Forward recovery voltage vs rate of rise of
forward voltage
0.5
0.4
0.3
0.2
0.1
Thermal impedance - ˚C/W
0
0.001 0.01 0.1
Fig.3 Maximum transient thermal impedance - junction to case
Time - (s)
1.0
d.c.
10
3/8
Loading...
+ 5 hidden pages