Dyna-Glo ANSI Z83.7-2000, CSA 2.14-2000, RMC-FA40DLX, RMC-FA100DLX, RMC-FA150DLX Instruction Manual

...
PROPANE CONSTRUCTION HEATER
USER’S INSTRUCTION MANUAL
RMC-FA40DLX (40,000 BTU/HR, FORCED - AIR) RMC-FA100DLX (70,000/100,000 BTU/HR, FORCED - AIR) RMC-FA150DLX (120,000/150,000 BTU/HR, FORCED - AIR)
RMC-FA40A (40,000 BTU/HR, FORCED - AIR) RMC-FA50A (30,000/50,000 BTU/HR, FORCED - AIR) RMC-FA100A (70,000/100,000 BTU/HR, FORCED - AIR) RMC-FA150A (120,000/150,000 BTU/HR, FORCED - AIR)
FGENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTION PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE EXPLOSION, BURN, ASPHYXIA
TION, CARBON MONOXIDE POISONING, AND/OR ELECTRIC SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSIST
ANCE OR HEA
TER INFORMA
TION SUCH AS AN
INSTRUCTION MANUAL, LADLES, ETC. CONTACT THE MANUFACTURER.
FRETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE
Dyna-Glo™Delux
MODELS
:
Dyna-Glo
MODELS:
CSA 2.14-2000, ANSI Z83.7-2000
5/05 Rev.1
Page 1
TABLE OF CONTENTS
• Introduction & Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
• General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
• Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
• Unpacking Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
• Size & Capacity Of Propane Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
• Installation To The Propane Gas Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
• Refilling The Propane Gas Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
• Leak Checking & Location Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
• Lighting & Shutdown Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
• Test Firing Heater & Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
• Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
• Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
• Replacement Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
• Warranty Information
FWARNING:FIRE, BURN, INHALATION, AND EXPLOSION HAZARD, KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS.
NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAIN THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS.
FWARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE.
Page 2
FWARNING: Not for use with ductwork.
SPECIFICATIONS:
Dyna-Glo Propane Forced Air Construction Heaters
The heater is designed and approved for use as a construction heater under ANSI Z83.7., CSA2.14
It is hard to anticipate every use which may be made of this heater.
CHECK WITH YOUR LOCAL
FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat producing products in specific applications. Your local authority can advise you about these.
IMPORTANT: Read this user's manual carefully and completely before trying to operate or service this heater. Improper use of this heater can cause serious injury or death from fire, explosion and carbon monoxide poisoning.
This is a direct-fired forced-air construction heater for either indoor or outdoor use. Its intended use is primarily the temporary heating of buildings or structures under construction, alteration or repair. All the products of combustion generated by the heater are forced through the heater and released into the area being heated. This heater operates at approximately 98%+ combustion efficiency but still produces a small amount of carbon monoxide. Humans can tolerate small amounts of carbon monoxide for short periods. Carbon monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning or death.
Model No.
RMC-FA40DLX
RMC-FA40A
-
RMC-FA(50A)
RMC-FA100DLX
RMC-FA100A
RMC-FA150DLX
RMC-FA150A
Input Rating
40,000 Btu/hr
-
30,000 Btu/hr 50,000 Btu/hr
70,000 Btu/hr 100,000 Btu/hr
120,000 Btu/hr 150,000 Btu/hr
Type of Gas Propane Propane Propane Propane
Gas Supply Pressures to Regulator Maximum
Cylinder Pressure Cylinder Pressure Cylinder Pressure Cylinder Pressure
Minimum (for purpose of Input Adjustment)
5psig 5psig 5psig 5psig
Manifold Pressure 11” W.C. 10” W.C. 9.5” W.C 8” W.C.
Gas Consumption
1.9lbs/hr
3.3lbs/hr
2.3lbs/hr
1.4lbs/h
4.6lbs/hr
3.3lbs/h - 5.6lbs/hr
7lbs/hr
5.6lbs/hr
Electrical Input 120V, 60Hz, 1 Ø 120V, 60Hz, 1 Ø 120V, 60Hz, 1 Ø 120V, 60Hz, 1 Ø
Amperage
Unload Load
0.35A
0.63A
0.58A
0.75A
0.6A
0.8A
0.6A
0.8A
Fan
Unload Load
3550rpm 3000rpm
3570rpm 3300rpm
3580rpm 3300rpm
3580rpm 3300rpm
Ignition Piezo/Manual Spark Continuous Spark Continuous Spark Continuous Spark
Spark Gap 0.16” 0.16” 0.16” 0.16”
Size (L
x
W
x H)
18.1” x 7.7” x 12.8” 18.1” x 7.7” x 12.8” 25.12” x 9” x 15.5” 25.12” x 9” x 15.5”
W
eight
15.2lbs (6.9kg) 15.2lbs (6.9kg) 22.7lbs (10.3kg) 22.7lbs (10.3kg)
Page 3
GENERAL SAFETY INSTRUCTIONS:
Accidents are always tragic especially because so many of them could have been prevented with lit­tle care and judgment.
There are some basic good practices, we hope you will follow for safe use of
your heater.
IMPORTANT SAFETY INFORMATION:
• Children should be carefully supervised, when they are in the area.
• Always maintain proper clearance from combustible materials. Minimum clearance from com­bustibles. Side - 24”; Top - 36”; Combustible and Front - 72”. Floor -noncombustible.
• Heater must be placed on level and adequate level and stable surface
• Never place anything including clothes or other flammable items on the heater.
• The appliance area shall be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.
• Do not modify or operate a heater which has been modified.
• Adequate clearance for accessibility and for combustion & ventilation air supply must be main­tained at all times when the heater is operating.
• Service and repair should be done by a qualified service person. The heater should be inspected before each use and at least annually by a qualified person. More frequent cleaning may be required as necessary. Do not service while hot or operating.
• Never connect heater to an unregulated gas supply.
• The heater is shipped from the factory for LP(Propane) gas. This heater is for use with propane gas only, do not convert heater to any other gas. Installation must conform to local codes or, in the absence, with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA NFPA 58 and the Natural Gas and Propane Installation Code CSA B149.1
• The minimum and maximum inlet pressures to the regulator from the gas tank are 5 psi and bottle pressure, respectively. Use only the regulator & hose assembly provided with the heater. Inspect the regulator/hose assembly prior to each use of the heater. If there is excessive abrasion or wear, or hose is cut, replace with regulator/hose assembly listed on the parts list prior to using this heater.
• Gas supply connections should be checked using a 50/50 solution of liquid dish soap and never use a flame to check for gas leaks.
• The electrical connection & grounding must comply with National Electrical Code. ANSI/NFP
A
70 or in Canada CSA
C22.1, Canadian Electrical Code, Part 1. Use only a properly
grounded three (3) prong receptacle.
• Do not restrict inlet or outlet by any means.
The flow of combustion and ventilation air is not to be
obstructed.
• Forced air heaters should not be directed toward any propane or gas container within 20 feet of the exit nozzle. The heater should also be located at least 6 feet away from any propane gas container (regulations in Canada are 10 feet)
• The propane cylinder supply system must be arranged to provide for vapour withdrawal from the operating cylinder
.
WARNING: Motor and fan must be running before lighting, during operation and at shutdown, in order to prevent a flame-out condition which could result in personal injury or property damage.
PRODUCT FEATURES:
• Portable, Stable & Fully Assembled • 100% Safety Shutoff System
• Wind Resistant & Rain Protected • Adjustable Input Ratings
• Continuous Spark Ignition or Piezo Electric Spark Ignition
Page 4
UNPACKING:
1. Remove heater from carton.
2. Remove all protective packing applied to heater for shipment.
3. Retain cartons and packaging material until unit is operated and found in good condition.
4. Checker heater for any shipping damage. If heater shows any external or internal damage, promptly inform dealer/distributor where you purchased heater.
INFORMATION ON SIZE * CAPACITY OR PROPANE GAS CYLINDERS:
The chart below shows the number and size of propane tanks needed to run this heater.
*Less gas is vaporized at lower temperatures.
You may need two or more 100 pound tanks or one larger tank in colder weather.
Temperature (°F) At
tank
Number of Tanks
40,000 BTU/h-
50,000BTU/h
100,000 BTU/h 150,000 BTU/h
Above 32°F 1 - 20lb 1 - 100lb 1 - 100lb
32°F 1 - 20lb 1 - 100lb 2 - 100lb
20°F 1 - 20lb 2 - 100lb 3 - 100lb
10°F 1 - 20lb 3 - 100lb 3 - 100lb
-10°F 2 - 20lb Use Larger Tank Use Larger Tank
-20°F 1 - 100lb Use Larger Tank Use Larger Tank
(See the parts list for your model of heater to get the specified regulator assembly.)
The propane (LP) gas tank must also be equipped with the following:
• A collar to protect the Propane gas valve.
• A shutoff valve terminating a Propane gas cylinder valve outlet as specified in the American National Standards for Compressed Gas Cylinder Valve Outlets and Inlet Connections.
• A safety relief valve having direct communications with the vapor space of the tank.
• An arrangement of vapor withdrawal.
The pr
opane (LP) gas pressur
e r
egulator
and hose assembly supplied with this heater
must be used without alteration.
The hose assembly shall be visually inspected prior to each use of the heater. If it is evident that there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation. The replacement hose assembly shall be that specified by the manufacturer. (See page 11, Part number 42)
Loading...