Power amplifier with 200 W or 400 W output power according to the IEC 283-3 standard within a
19“ - cabinet (3 HU) providing the following functions:
• supported are 115/230V AC mains as well as 24V DC emergency power source
• power amplifiers DPA 4120 providing 200 W or DPA 4140 providing 400 W output power, idling and short-circuit
protection
• output transformer for balanced, floating 100 V speaker networks of optionally 70 V, 50 V or
4 ohms for low-impedance operation
• optional input modules:
standard operation INPUT MODULE with level control, electronically balanced input and MONITOR output with
optional transformer or
REMOTE MODULE for controlling and monitoring the PROMATRIX system, electronic level controls, electronically
balanced input and MONITOR output with optional transformer
• integrated stand-by power supply
• mains POWER ON/OFF switch
• ground lift switch
• remotely controllable mains and battery operation with initial current inrush limiter
• power-on switching noise suppression
• status-LED indicators for operation (READY), STANDBY, thermal overload (PROTECT) and
occurrence of GROUND FAULT conditions at the power output
• fault message according to the IEC 849 standard
• TEST button to switch between system and average operation, respectively a RESET button to restart after the
occurrence of ground fault conditions
• LED level meter instrument with a display range of -13 dB to 0 dB and CLIP
• integrated relays for single call and obligatory reception
• active, temperature controlled ventilation
• pilot tone and ground fault surveillance module according to the DIN/VDE 0800 standard (optional)
23
24
Indicators, controls and connections
867
B20191817
B20191817
1 2
9
AAA
POWER
101 11213
T4A FOR 230V
T8A FOR 115V
AC MAINS INPUT
115V /230V AC 50-60 Hz
CAU TION:
FOR CONTINUED PROTECTION AGAINST RISK O F FIRE
REPLACE WITH SAME TYPE AND VALUE FUSE INDICAT ED.
ATTENTION:
REMPLACER PAR UN FUSIBLE DE MEME TYPE
COMME INDIQ UE.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
AVIS:
CAUTION
RISK OF ELECTRIC SHOCK
DO NO T OPEN
RISQ UE DE CHOC ELECTRIQUE. NE PAS OUVRIR.
DC INPUT 24V
+
CIRCUIT T O
CHASSIS SWITCH
GROUNDED
UNGRO UNDED
VOLTAGE
SELECTOR
115V 230V
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
VO R ÖF F NEN DES G ER ÄTES NET Z STECKER Z IEHEN
400 WATT S PO WE R AM P L IFI ER
DPA 4140
121629
MADE IN GERMANY
ADDRESS
OUT PUT
VO LTAG E
POWER OUTPUT
1 2 3 4 5
DPA 4140
R EAD Y
G RO UN D
C LIP
0dB
-13dB
FAULT
TES T
STAN DBY
PR OTE CT
3
4
5
B
INPUT
AB
2
5
4
3
1
LEVEL
REMOTE
CONTROL
THRU
6
7
8
9
100
90225
14
15
16
9
AAA
POWER
101 112B
T4A FOR 230V
T8A FOR 115V
AC MAINS INPUT
115V /230V AC 50-60 Hz
CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE
REPLACE WITH SAME TYPE AND VALUE F USE INDICATED.
REMPLACER PAR UN FUSIBLE DE MEME TYPEATTENTION:
COMME INDIQUE.
WARNING:
DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
AVIS:
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
RISQUE DE CHOC ELECTRIQUE. NE PAS OUVRIR.
DC INPUT 24V
+
CHASSIS SWITCH
CIRCUIT TO
GROUNDED
UNGROUNDED
VOLTAGE
SELECTOR
115V 230V
1 level meter instrument
2 CLIP indicator
3 Test and Reset button TEST
4 STANDBY indicator
5 Fault indicator PROTECT
6 Fault indicator GROUND FAULT
7 Mode indicator READY
8 Ventilation louvres
9 Mains power switch POWER
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
VO R Ö FF NEN DES G ERÄTES NET Z STECKER Z IEHEN
15
INPUT
THRU
REMOTE
CONTROL
ADDRESS
IN
14
A
21
B
22
OUT
STATUS
90222
23
121629
O UT PUT
VO LTAGE
POWER OUTPUT
1 2 3 4 5
DPA 4140
M ADE IN GERMANY
AD DRESS
AB
10 Mains power connector AC MAINS INPUT
11 Mains fuse FUSE
12 Mains VOLTAGE SELECTOR
13 Input LEVEL control
14 INPUT socket
15 THRU socket
16 REMOTE CONTROL connector
17 POWER OUTPUT
18 Ventilation louvres
25
19 CIRCUIT ⊥ TO CHASSIS SWITCH
20 DC INPUT 24V = (battery)
21 IDENT ADDRESS switch
22 REMOTE CONTROL connectors
23 STATUS indicator
A locking screws power supply printed board
B locking screws INPUT MODULE
Contents
Performance Features .........................................................................................................................23
Indicators, controls and connections .................................................................................................... 25
The amplifiers DPA 4120 and DPA 4140 are specially designed for the power-consistent and reliable operation of PAsystems. The DPA 4120 and DPA 4140 are intended to be used in company intercom, alarm and background music
transmission installations, offices and commercial areas, congregation and sport centers, schools, churches, hotels,
hospitals, shopping malls and super markets, cruise ships, and other similar applications.
2.Installation
When installing the amplifiers, it is important to assure that for ventilation reasons the front-to-rear air circulation is
guaranteed (for details on 19"-case or 19“-rack shelf installation please refer to paragraph 9).
To maintain EMC it is necessary that all input, output, and control lines – except for the power cords – are shielded.
Within metal housings or closed rack shelf systems, unshielded output and control cabling is allowable. Shielding is
accomplished by connecting the individual cable screens to the enclosure or rack shelf ground potential.
The amplifier has to be protected from:
- water drops or splashes
- direct sunlight
- high ambient temperatures and the direct radiation of heat sources
- high humidity and moisture
- heavy dust
- massive vibrations
Moving the amplifier from a cold into a warm environment can result in the occurrence of condensation on inner parts.
Operating the appliance is only permissible after it has accommodated to the altered temperature (approximately after
one hour).
Should it happen that foreign solid parts or liquids inadvertently intrude the enclosure, unplug the device from the
power source and have it checked by a DYNACORD service center, before using it again.
Cleaning the appliance should not be performed using chemical solvents or sprays, as this might damage the finish
and moreover could cause hazard fire.
3.Before the first operation
These power amplifiers are designed to be operated with different input modules. The general input module NRS
90225 is meant for all conventional applications. It allows to remotely start the amplifiers via control lines, monitor their
operation by use of the incorporated fault relay, and monitor the transmitted audio signals through the monitor output.
Using the remote control module NRS 90222, the amplifiers are connected to the PROMATRIX manager DPM 4000
via RS-485 remote interface providing complete remote operation and surveillance. The desired input module has to be
inserted into the module shaft on the rear of the power amplifier. It has to be tightened using the two locking screws
(B) (refer also to the paragraphs 8.1 and 8.2).
3.1Mains operation
For normal AC mains operation, the included mains cord has to be connected to a 230V or 115V 50/60Hz wall outlet.
On the appliance itself, the cord has to be connected to the 3-pole mains socket (10).
CautionThe appliance is factory preset to 230V AC. Switching to 115V AC is accomplished using the voltage
selector (12).
27
DPA 4120: For 115V AC operation, the mains fuse (11) has to be replaced by a slow blowing
4 ampere type , labeled "T4A" (see also paragraph 11.1).
DPA 4140: For 115V AC operation, the mains fuse (11) has to be replaced by a slow blowing
8 ampere type , labeled "T8A" (see also paragraph 11.2).
If the appliance is correctly connected and mains is present the green STANDBY indicator (4) will light. To remotely
start the amplifier when it is being operated on the mains, it is necessary to interconnect the contacts 3 - POWER
REMOTE and 2 - GROUND STANDBY on the pin terminal strip REMOTE CONTROL (16) (see also paragraph 5.6).
The main power switch POWER (9) on the rear of the appliance is meant for service and maintenance purposes. This
allows bridging the mains switching relay, which provides the possibility to operate the amplifier without remote start.
NoteThe main power switch POWER (9) on the appliance's rear is only meant for maintenance . Remotely
switching off the device is not possible when the POWER switch is engaged.
Both amplifiers, the DPA 4120 and the DPA 4140, employ power-on switching delays of approximately 3 sec. After
this time, the green READY indicator lights and the READY fault message relay picks up when no error is being
detected (see also paragraph 6.2).
3.2Battery operation 24V DC
The amplifiers, DPA 4120 and DPA 4140, use the mains or alternatively an external 24V battery as power source.
Switching to battery is performed via integrated relays.
The battery has to be connected on the rear of the amplifiers (20) using insulated 6.3x0.8 mm AMP flat plug
connectors. The amplifiers are protected against polarity-mismatch. Each, the positive and negative conductors are
internally protected by fuses, located on the printed board assembly 85270 (DPA 4120) respectively 85268 (DPA
4140) (see also paragraph 11, figure 10 and 11).
The cable used for battery connection has to be at least 1.5 mm2 in diameter (DPA 4120) respectively 2.5 mm2 (DPA
4140). Using these diameters, the cable length for the one way distance should not exceed 4.0 m (max. voltage drop
<1V).
CautionThe DPA 4120 and DPA 4140 are to be operat ed only using ungrounded batteries or batteries with
grounded negative pole. Operation with grounded positive pole is not permissible.
4.INPUT
The electronically balanced INPUT (14) providing a sensitivity of 775mV = 0dBu is meant for the connection of control
amplifiers. In case it is intended to supply several power amplifiers with identical input signals, these signals can be
taken from the THRU connector (15) (see also figure 1 and 2).
The input is prepared to be retrofitted with a input transformer. In case a floating input is needed, it is necessary to
install the optional extension NRS 90208 (see also paragraph 8.3).
On the general input module NRS 90225 the input level is set with the level control (13). For the remote control
module NRS 90222 the input level is determined by the setting of the internal electronic level control of the
PROMATRIX manager DPM 4000 (please also refer to the PROMATRIX handbook).
28
figure 1 connections of the input sockets
figure 2 LF cable for coupling two amplifiers DPA 41xx
5.Outputs
5.1POWER OUTPUT
The power output is balanced and off-ground potential. The output is factory-configured for the connection of 100V
loudspeaker systems. Connection has to be performed by inserting the supplied 5-pole plug into the power output
socket (17). Switching the output voltage to 70V, 50V or to low impedance operation (4 ohms) is possible using the
plug-in bridge B411 on the printed board assembly 84187 (DPA 4120) respectively 84175 (DPA 4140) (see also
paragraph 7).
figure 3 connection of the power output
5.2POWER OUTPUT for 100V (70V or 50V) loudspeaker systems
If the distance between the amplifier and the loudspeakers exceeds 50 m, it is recommended to operate the speaker
systems using 100V matching transformers, to reduce line attenuation. This additionally offers a simple way of
distributing the output power capacity. In this way it is possible to connect a maximum of as many loudspeaker
systems as it takes until the total power consumption of the entire speaker network equals the power output capacity
29