SERIES 626 & 628 | INDUSTRIAL PRESSURE TRANSMITTER/TRANSDUCER
FEATURES/BENEFITS
Standard:
Robust316LSSoillledsensor
CE Approved Design
626: 0.25% FS
628: 1.0% FS
Optional:
Advanced environmental protection
C-276 wetted materials
Digital or Analog Outputs (I2C)
Customrangeconguration
Overpressure and/or vacuum
626/628 Pressure Transmitters with
General Purpose Housing (-GH)
protection
APPLICATIONS
Booster stations
Pumping systems
Irrigation equipment
PTO systems
Submersible pump control
626/628 Pressure Transmitters
with Conduit Box Housing (-CB)
and LCD display
DESCRIPTION
The SERIES 626 & 628 Pressure Transmitters feature a piezo-resistive sensor contained in a compact, rugged, NEMA 4X (IP66) stainless steel general purpose housing or cast aluminum conduit housing.
Dwyer offers optional congurations to address multiple common points of failure that have traditionally challenged the use of similar products in extreme
conditions. The 626 & 628 are uniquely suited for precision irrigation and additional outdoor power equipment applications. The corrosion resistant 316L stainless steel wetted parts allow the Series 626 & 628 transmitters to measure pressure in a multitude of processes from simple irrigation systems to chemical dosing and injection systems. Optional wetted materials such as C-276 offer chemical compatibility with aggressive media. The 626 & 628 can be
congured to provide advanced environmental protection. This includes, but is not limited to, freeze/thaw protection for outdoor cold weather applications, vibration resistance, and/or overpressure protection to protect the sensors against pressure surges or pump cavitation. The Series 626 & 628 are available
in absolute and gauge pressure ranges with a variety of optional outputs, process connections, electrical terminations, and select agency approvals to allow you to select the correct transmitter for your application.
ContactDwyerInstrumentstodaytodiscussyourspecicapplicationneeds.
SPECIFICATIONS
Wetted Materials Type 316L SS. (Consult factory for additional options)
Temperature Limit 0 to 200°F (-18 to 93°C).
Compensated Temperature
Thermal Effect ±0.2% FS/°F (includes zero and span).
Pressure Limits See table on catalog page.
Power Requirement
Output Signal
Response Time 300 ms.
Loop Resistance
Current Consumption
Electrical Connections
Process Connections 1/4˝ male or female NPT and BSPT.
Enclosure Rating NEMA 4X (IP66).
Agency Approvals Standard: CE; Optional: NSF/ANSI 61/372, ANSI/UL 218, ANSI/UL 508, NEPA 20
Service Compatible gases and liquids.
Accuracy
Display Optional 4-1/2 digit LCD eld attachable display.
Stability 1.0% FS/year (typ).
Weight 10 oz (283 g).
626: 0.25% FS, 0.20% RSS; 628: 1.0% FS, 0.5% RSS; 626 Absolute Ranges: 0.5% FS, 0.30% RSS. (Includes linearity, hysteresis, and repeatability).
0 to 175°F (-18 to 79°C).
Range
10 to 30 VDC (for 4 to 20 mA, 0 to 5, 1 to 5, VDC outputs); 13 to 30 VDC (for 0 to 10 VDC output); 5 VDC ±0.5 VDC (for 0.5 to 4.5 VDC ratiometric output), 10 to 35 VDC (for 4 to 20 mA with -CB option); 13 to 35 VDC or isolated 16 to 33 VAC (for selectoable output with -CB option). 4 to 20 mA, 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC, or 0.5 to 4.5 VDC, or selectable 0 to 5, 1 to 5, 0 to 10, 2 to 10 VDC for -CB option.
0 to 1000 Ohms max. R max = 50 (Vps-10) Ohms (4 to 20 mA output), 0 to 1250 Ohms max. Rmax = 50(Vps-10)
Ohms (4 to 20 mA output with -CB option), 5K Ohms (0 to 5, 1 to 5, 0 to 10, 0.5 to 4.5 VDC output).
38 mA maximum (for 4 to 20 mA output); 10 mA maximum (for 0 to 5, 1 to 5, 0 to 10, 0.5 to 4.5 VDC output); 140 mA maximum (for all 626/628/629-CH with optional LED). Conduit housing (-CH): Terminal block, 1/2˝ female NPT conduit; General purpose housing (-GH): Cable DIN EN
175801-803-C.
dwyer-inst.com
DWYER INSTRUMENTS, INC.
T: 219-879-8000 | F: 219-872-9057 | info@dwyermail.com 800-872-9141
®
DIMENSIONS
6-23/64 [161.528]
L
LIQUID TIGHT FITTING CORD DIAMETER RANGE .200 (5.08
TO .350
TO 8.89)
11/32 [34.131]
HOW TO ORDER
Use the bold characters from the chart below to construct a product code.
SERIES
626 - 0.25% full scale accuracy 628 - 1.0% full scale accuracy
RANGE
-00 - 0 to 15 psia*
-01 - 0 to 30 psia*
-02 - 0 to 50 psia*
-03 - 0 to 100 psia*
-04 - 0 to 200 psia*
-05 - 0 to 300 psia*
-06 - 0 to 5 psi
-07 - 0 to 15 psi
-08 - 0 to 30 psi
-09 - 0 to 50 psi
-10 - 0 to 100 psi
-11 - 0 to 150 psi
-12 - 0 to 200 psi
-13 - 0 to 300 psi
ACCESSORIES
Model Description Model Description A-164 A-62X-LCD A-960
2-1/8 [53.975] 1/4 NPT OR BSPT
23/32 [18.256]
59/64 [23.415]
Conduit Housing General Purpose Housing
FEMALE FITTING
2-21/32 [67.46] OPTIONAL 1/4 NPT OR BSPT MALE FITTING
626 -05 -CH -P3 -E1 -S1 -NIST
-14 - 0 to 500 psi
-22 - 0 to 600 psi
-15 - 0 to 1000 psi
-16 - 0 to 1500 psi
-18 - 0 to 3000 psi
-19 - 0 to 5000 psi
-26 - 0 to 8000 psi
-67 - 0 to 0.5 bar*
-71 - 0 to 2.5 bar*
-75 - 0 to 10 bar*
-81 - 0 to 40 bar*
*Only available on
-GH housing models
16.4´ (5 m) cable with M-12 4-pin female connector Field-upgradeable LCD
3´ (1 m) Packard cable
3-7/32 [81.756] OPTIONA LCD
A-961 A-962
7/8 [22.23]
HEX
9´ (3 m) Packard cable 20´ (7 m) Packard cable
1/4 NPT
2-27/64 [61.52]
3-13/64 [81.36]
Ø55/64 [21.83]
OPTIONS
-AT - Aluminum tag
-LED - Bright red LED display
-NIST - NIST traceable calibration certicate
-NW - NSF/ANSI 61/372 certied
SIGNAL OUTPUT
-S1 - 4 to 20 mA
-S2 - 1 to 5 VDC
-S4 - 0 to 5 VDC
-S5 - 0 to 10 VDC
-S7 - 0.5 to 4.5 VDC
-S8 - 0 to 5, 1 to 5, 0 to 10, 2 to 10 VDC
ELECTRICAL CONNECTIONS
-E1 - Cable gland with 3´ of prewired cable
-E3 - Cable gland with 9´ of prewired cable
-E4 - DIN EN 175801-803-C
-E5 - 1/2˝ female NPT conduit
-E6 - M-12 4-pin connector UL listed
-E8 - Packard connector
-E9 - M-12 4-pin connector non-UL listed
PROCESS CONNECTIONS
-P1 - 1/4˝ male NPT
-P2 - 1/4˝ female NPT
-P3 - 1/4˝ male BSPT
-P5 - 1/4˝ female SAE w/ refrigerant
valve depressor
-P9 - 1/2˝ male NPT
HOUSING
-CB - Conduit box housing
-GH - General purpose housing
Important Notice: Dwyer Instruments, Inc. reserves the right to make changes to or discontinue any product or service identied in this publication without notice. Dwyer advises its customers to obtain the
latest version of the relevant information to verify, before placing any orders, that the information being relied upon is current.
DWYER INSTRUMENTS, INC.
dwyer-inst.com
T: 219-879-8000 | F: 219-872-9057 | info@dwyermail.com 800-872-9141
DS-626/628 Rev. 6 | 1/18