Dwyer PBV User Manual

®
PVC Body
0
50
100
150
200
250
62
92
122
152
182
212
73
140
32
1/2˝ to 2˝
2˝ to 4˝
232
40
WORK ING T EMPERATURE (°F)
WORKING PRESSURE (psi)
PRESSURE - TEMPERATURE RATINGS
SERIES PBV
E
D
C
F
B
A
E
F
D
C
B
A
PVC Body
C
Series PBV Automated Ball Valves - 2-Way Plastic
Specifications - Installation and Operating Instructions
NEUMATIC DOUBLE ACTING – inches/(mm)
P A B
C
D
E
ACT.
eight
W
lb)
(
4-21/32
118.2)
(
-49/64
1
44.8)
(
-1/8
5 (130.1) 4-21/64 (109.9)
A1
D
.52
1
4-23/32
136.4)
(
-49/64
1
44.8)
(
-1/8
6 (154.5) 4-21/64 (109.9)
A1
D
.86
1
4-31/32
126.2)
(
-49/64
1
44.8)
(
-1/2
6 (165.1) 4-21/64 (109.9)
A1
D
.29
2
5-3/16
131.7)
(
-49/64
1
44.8)
( 7 (177.8) 4-21/64 (109.9)
A1
D
.30
3
6-1/32
153.1)
(
-51/64
2
71)
( 8 (203.2) 5-31/64 (139.4)
A2
D
.03
5
1-1/2˝
1-1/4˝
3/4˝
1/2˝
PNEUMATIC SPRING RETURN – inches/(mm) A B
C
D
E
ACT. Weight
-7/32
5
12.7)
( 2-51/64 (71) 5-1/8
130.1)
( 5-31/64 (139.4) SR2
3.12
-17/32
5
140.7)
( 2-51/64 (71) 6-1/8
154.5)
( 5-31/64 (139.4) SR2
3.46
-35/64
5
140.9)
( 2-51/64 (71) 6-1/2
165.1)
( 5-31/64 (139.4) SR2
3.89
5 ( 2-51/64 (71) 7 ( 5-31/64 (139.4) SR2
4.90
-3/4
146)
177.8)
-31/64
6
164.5)
( 3-11/64 (80.5) 8
203.2)
( 6-3/8 (161.9) SR3
6.68
-1/2˝
1
-1/4˝
1
˝
1
/4˝
3
/2˝
1
(lb)
2˝ 7-51/64
198)
(
-51/64
2
71)
(
-3/4
8 (222.2) 5-31/64 (139.4)
A2
D
.98
6
˝
2
-47/64
6
171.1)
( 3-11/64 (80.5) 8-3/4
222.2)
( 6-3/8 (161.9) SR3
8.63
2-1/2˝ 9-7/32
234.1)
(
-5/32
3
80.1)
(
1-7/8
1 (301.7) 6-3/8 (161.9)
A3
D
5.92
1
-1/2˝
2
-37/64
9
243.5)
( 4-53/64 (122.9) 11-7/8
301.7)
( 10-11/16 (271.5) SR6
27.07
Bulletin V-17
3˝ 9-17/32 ( 3 ( 1 (301.7) 6-3/8 (161.9) D 1
242)
-5/32
80.1) 1-7/8
A3
6.34
˝
3
-23/32
9
247.1)
( 4-53/64 (122.9) 11-7/8
301.7)
( 10-11/16 (271.5) SR6
27.49
˝
4 10-27/64 (264.6) 3-23/32
94.4)
(
1-7/8
1
301.7)
(
-7/64
8 (207) DA4
25.07
4˝ 12-35/64 (319)
-25/64
5
136.9)
(
1-7/8
1
301.7)
(
2-29/32
1
327.9)
( SR7
41.82
ELECTRIC ACTUATOR – inches/(mm) A B
C
D
E
F
ACT. Weight (lb)
1/2˝ 3/4˝ 1-1/4˝ 1-1/2˝ 2-1/2˝ 3˝ 6-13/64 (157.7) 4 (101.6)
(130.3) 5-5/8 (143)
2-5/16 (58.6) U11
5-1/8
7-5/64 (180) 4-1/4 (107.9)
6-7/8 (174.7) 2-27/64 (61.7) V12
9.47
6-33/64 (165.4) 4 (101.6)
(155.5)
5-5/8 (143) 2-5/16 (58.6) U11
5.81
7-13/32 (188.1) 4-1/4 (107.9)
6-1/8
6-7/8 (174.7) 2-27/64 (61.7) V12
9.81
6-17/32 (165.8) 4 (101.6)
(165.1) 5-5/8 (143) 2-5/16 (58.6) U11
6.24
6-1/2
7-13/32 (188.1) 4-1/4 (107.9)
6-7/8 (174.7) 2-27/64 (61.7) V12
10.24
6-3/4 (157.7) 4 (101.6)
5-5/8 (143) 2-5/16 (58.6) U11
7.25
5.47
*INCL UDES DE CL UTC HA BLE M ANUAL  OVER RIDE  AND H ANDWH EEL
The Series PBV is ideal for service in industrial, chemical, turf and irrigation, and
pool and spa applications, as well as for use with potable water. The valve features a shear-proof stem designed to prevent leakage in the event of damage, reinforced TFE seats and EPDM seals for longer life, and an all-plastic construction (PVC or CPVC) for heavyweight durability at a lightweight cost. Valves also come standard with selectable NPT or socket process connections. The PBV i s an economical automate d valve package with eit her an electric or pneumatic actuator. Electrically actuated models are weatherproof, NEMA 4, powered by standard 115 VAC supply, and are available in either two-position or proportional control. Two-position actuators use the 115 VAC input to drive each of the valve ports open or closed, while the modulating actuator accepts a 4 to 20 mA input for infinite valve positioning. Actuator features include thermal overload protection to withstand stall conditions, visual position indication and a permanently lubricated gear train. The pneumatic double acting actuator uses an air supply to drive each of the actuator ports. Spring return pneumatic actuators use the air supply to drive the valve stem one direction, and internally loaded springs return the valve to its original position. Also available is the SV3 solenoid valve to electrically switch the supply pressure between the air supply ports. Actuators are constructed of anodized aluminum and are epoxy coated for years of corrosion free service.
7-39/64 (193.2) 4-1/4 (107.9)
7
(177.8)
6-7/8 (174.7) 2-27/64 (61.7) V12
11.25
7-1/32 (170.3) 4 (101.6)
5-5/8 (143) 2-5/16 (58.6) U11
7.73
7-57/64 (200.6) 4-1/4 (107.9)
8
(203.2)
6-7/8 (174.7) 2-27/64 (61.7) V12
11.73
7-33/64 (191.2) 4-1/4 (107.9) 8-3/4 (222.2) 6-7/8 (174.7) 2-27/64 (61.7) U12
11.68
V12
13.68
9-13/32 (238.7) 4-1/4 (107.9) 11-7/8 (301.7) 6-7/8 (174.7) 2-27/64 (61.7)
U13
19.62
V13
21.62
12-7/8 (326.8) 7 (177.8) 11-7/8 (301.7) 7 (177.8) 2-3/8 (60.3) U15
26.04
V15
4˝ 13-13/16 (350.7) 7 (177.8) 12-15/16 (328.6) 7 (177.8) 2-3/8 (60.3)
V15
U15
32.47
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
Phone: 219/879-8000 www.dwyer-inst.com
PECIFICATIONS
S Service: Compatible liquids or gases. Body: 2-way. Line Size: 1/2˝ to 4˝.
nd Connections: Female NPT or socket (for 1/2˝ through 2˝); socket only (for 2-
E
/2˝ through 4˝).
1
ressure Limit: 1/2˝ to 2˝: 232 psi (16.0 bar) @ 73°F (23°C); 2-1/2˝ to 4˝: 150 psi
P
10.3 bar) @ 73°F (23°C) WOG. Vacuum: 29˝ Hg.
(
Wetted Materials:
Body, End Connectors: PVC or CPVC; Ball, Stem: PVC or CPVC;
eat: TFE;
S
tem Seal: EPDM.
S
emperature Limit: 32 to 140°F (0 to 60°C).
T
ther Materials: Stem Bearing: Polypropylene (1-1/4˝ and up).
O
ACTUATORS Electric
ower Requirements: 120 VAC, 50/60 Hz, single phase. Optional 220 VAC, 24
P
AC, 12 VDC, and 24 VDC.
V
ower Consumption: (Locked Rotor Current): Two Position: 1/2˝ to 1-1/2˝: .55A,
P
2˝ to 4˝: 0.75A. Modulating: 1/2˝ to 2˝: 0.75A, 2-1/2˝: 1.1A, 3˝ and 4˝: 0.75A. Cycle Time: (per 90°): Two Position: 1/2˝ to 1-1/2˝: 2.5 sec., 2˝ and 2-1/2˝: 5 sec., 3˝ and 4˝: 15 sec. Modulating: 1/2˝ to 2-1/2˝: 5 sec., 3˝ and 4˝: 15 sec.
Duty Cycle: Two Position: 1/2˝ to 1-1/2˝: 75%, 2˝ to 4˝: 25%. Modulating: 75%.
nclosure Rating: NEMA 4. Optional NEMA 7 (Class 1, Div. II groups A, B, C,
E
).
D
ousing Material: Aluminum with thermal bonding polyester powder finish.
H Temperature Limit: 0 to 150°F (-18 to 65°C). Conduit Connection: 1/2˝ female NPT. Modulating Input: 4 to 20 mA. Standard Features: Manual override and visual position indicator except
odulating units.
m
Pneumatic “DA” and “SR” Series Type: DA series is double acting and SR series is spring return (rack and pinion). Normal Supply Pressure: 80 psi (5.5 bar).
aximum Supply Pressure: 120 psig (8 bar).
M
ir Connections: 1/4˝ female NPT.
A
ir Consumption: (per stroke) DA1: 2.32 cu. in.; DA2: 9.34 cu. in.; DA3: 17.21
A
u. in.; DA4: 20.5 cu. in.; SR2: 9.34 cu. in.; SR3: 17.21 cu. in.; SR6: 54.34 cu. in.;
c SR7: 85.43 cu. in. Cycle Time: (per 90°) DA1: .03 sec.; DA2: .04 sec.; DA3: .08 sec.; DA4: .12 sec.; SR2: .09 sec.; SR3: .14 sec.; SR6: .46 sec.; SR7: .83 sec.
ousing Material: Anodized aluminum body and epoxy coated aluminum end
H
aps.
c
emperature Limit: -4 to 180°F (-20 to 82°C).
T
ccessory Mounting: NAMUR standard.
A Standard Features: Visual position indicator.
SERIES PBV AUTOMATED 2-WAY PLASTIC BALL VALVES - PVC MODELS
Size
1/2˝ 3/4˝ 1˝ 1-1/4˝ 1-1/2˝ 2˝ 2-1/2˝ 3˝ 4˝
Note: All spring return actuators are factory standard as spring (fail) close. For spring (fail) open valves, add suffix “-FO” to the model number.
SERIES PBV AUTOMATED 2-WAY PLASTIC BALL VALVES - CPVC MODELS
Size
1/2˝ 3/4˝ 1˝ 1-1/4˝ 1-1/2˝ 2˝ 2-1/2˝ 3˝ 4˝
Note: All spring return actuators are factory standard as spring (fail) close. For spring (fail) open valves, add suffix “-FO” to the model number.
Double Acting Pneumatic Spring Return Pneumatic Two Position Electric Modulating Electric
CV
25 51 97 204 285 540 712 1294 2629
CV
25 51 97 204 285 540 712 1294 2629
Model PBVPDA102 PBVPDA103 PBVPDA104 PBVPDA105 PBVPDA206 PBVPDA207 PBVPDA308 PBVPDA309 PBVPDA410
Double Acting Pneumatic
Model PBVCDA102 PBVCDA103 PBVCDA104 PBVCDA105 PBVCDA206 PBVCDA207 PBVCDA308 PBVCDA309 PBVCDA410
Model PBVPSR202 PBVPSR203 PBVPSR204 PBVPSR205 PBVPSR306 PBVPSR307 PBVPSR608 PBVPSR609 PBVPSR710
Spring Return Pneumatic
Model PBVCSR202 PBVCSR203 PBVCSR204 PBVCSR205 PBVCSR306 PBVCSR307 PBVCSR608 PBVCSR609 PBVCSR710
Model PBVPU1102 PBVPU1103 PBVPU1104 PBVPU1105 PBVPU1106 PBVPU1207 PBVPU1308 PBVPU1509 PBVPU1510
Two Position Electric Modulating Electric
Model PBVCU1102 PBVCU1103 PBVCU1104 PBVCU1105 PBVCU1106 PBVCU1207 PBVCU1308 PBVCU1509 PBVCU1510
Model PBVPV1202 PBVPV1203 PBVPV1204 PBVPV1205 PBVPV1206 PBVPV1207 PBVPV1308 PBVPV1509 PBVPV1510
Model PBVCV1202 PBVCV1203 PBVCV1204 PBVCV1205 PBVCV1206 PBVCV1207 PBVCV1308 PBVCV1509 PBVCV1510
LECTRIC ACTUATOR
E
. BASIC INSTALLATION
I
. Operate valve manually and place in the open position. (Note: ALL ELECTRIC
1
CTUATORS ARE SHIPPED IN THE OPEN POSITION.)
A
. Remove any mechanical stops the valve might have. (DO NOT REMOVE ANY
2
PARTS NECESSARY FOR THE PROPER OPERATION OF THE VALVE, SUCH AS THE PACKING GLAND, PACKING NUT, ETC.)
3. Ensure that the actuator output shaft and valve stem are aligned properly. If hey are not, operate the valve manually until they are correct.
t
. Mount actuator to valve. Do not tighten nuts and bolts at this time.
4
. Remove actuator cover.
5
. Bring power to the actuator. CAUTION: Make sure power is OFF at the main
6
box.
7. Wire the actuator per the diagram attached to the inside of the cover. Special
actuators (those with positioner boards, etc.) will have diagrams enclosed
nside the cover.
i
. Securely tighten bolts used to mount the actuator to a mounting bracket or
8
irectly to the valve mounting pad if it is ISO5211 compliant.
d
9. Cycle the unit several times and check the open and closed positions of the
valve. Cams are pre-adjusted at the factory; due to the variety of valve designs and types, however, slight adjustments might be required. (SEE II and III).
10. Replace cover and tighten screws.
I. TO SET THE OPEN POSITION
I
. Cycle the valve to the open position by applying power to terminals #1 and #2.
1
The top cam and switch control this position. In the open position, the set screw
n the top cam will be accessible.
i
. If the valve is not open completely:
2
. Slightly loosen the 8-32 x 1/4” set screw on the top cam.
A B. Rotate the cam clockwise (CW) by hand until the switch makes contact.
Contact is made when a slight click can be heard. By making incremental CW movements of the top cam, the valve can be positioned precisely in the desired position.
C. When the top cam is set, tighten the set screw securely.
3. If the valve opens too far:
A. Apply power to terminals #1 and #3. This will begin to rotate valve CW.
When valve is full open and in the exact position desired, remove power
from actuator. B. Loosen the set screw in the top cam. C. Rotate the top cam counterclockwise (CCW) until the switch arm drops off
the round portion of the cam onto the flat section. A slight click can be heard
as the switch changes state. D. Continue applying power to terminals #1 and #3 until valve is in the desired
position.
III. TO SET THE CLOSED POSITION
1. Apply power to terminals #1 and #3 to move the valve toward the closed position. The bottom cam and switch control the closed position. In the closed position, the set screw in the bottom cam will be accessible.
2. If the valve is not closed completely: A. Slightly loosen the 8-32 x 1/4” set screw on the bottom cam. B. Rotate the cam counter-clockwise (CCW) by hand until the switch makes
contact. Contact is made when a slight click can be heard. By making incremental CCW movements of the bottom cam, the valve can be positioned precisely in the desired position.
C. When the top cam is set, tighten the set screw securely.
3. If the valve closes too far: A. Apply power to terminals #1 and #2. This will begin to rotate valve CCW.
When valve is fully closed and in the exact position desired, remove power
from actuator. B. Loosen the set screw in the top cam. C. Rotate the top cam clockwise (CW) until the switch arm drops off the round
portion of the cam onto the flat section. A slight click can be heard as the
switch is no longer making contact with the round part of the cam. D. Continue applying power to terminals #1 and #2 until valve is in the desired
position.
V. MAINTENANCE
I
nce the actuator has been properly installed, it requires no maintenance. The
O
ear train has been permanently lubricated and in most cases will never be
g
isturbed. In the event it becomes necessary to open the gear box for any reason,
d however, Shell Darina
®
#2 grease is recommended for re-lubricating.
V. DUTY CYCLE
ost standard electric actuators are rated for 25% duty cycle at 100% ambient
M
emperature at the rated torque.
t
I. THERMAL OVERLOAD
V
All actuators are equipped with thermal overload protection to guard the motor against damage due to overheating.
II. MECHANICAL OVERLOAD
V
ll actuators are designed to withstand stall conditions. It is not recommended to
A
ubject the unit to repeated stall conditions.
s
VIII. SPARE PARTS
When ordering parts, please specify: A. Model # B. Serial # C. Part Description
ecommended spare parts include:
R
. Standard actuator: set of cams and switches.
A
. Actuators w/positioner: set of cams and switches; 1K potentiometer; valve
B positioner board.
IX. NEMA 7 ELECTRIC ACTUATORS
In general, operation and maintenance of a NEMA 7 electric actuator is no different
hat of a NEMA 4 actuator. However, some precautions must be followed:
t
. DO NOT under any circumstances remove the cover of the actuator while in a
1
azardous location. Removal of the cover while in a hazardous location could
h cause ignition of hazardous atmospheres.
2. DO NOT under any circumstances use a NEMA 7 electric actuator in a hazardous location that does not meet the specifications for which the actuator was designed.
3. Always mount and cycle test the actuator on the valve in a non-hazardous location.
4. When removing the cover, care must be taken not to scratch, scar of deform the flame path of the cover and base of the actuator, since this will negate the NEMA rating of the enclosure.
5. When replacing the cover on actuators rated for both NEMA 4 & 7, take care that the gasket is in place to assure proper clearance after the cover is secured. After the cover screws are tightened, the clearance between the cover and the base should be checked. A .002” thick by 1/2” wide feeler gauge is used for this; it must not enter between the two mating faces more than .125".
6. All electrical connections must be in accordance with the specifications for which the unit is being used.
7. Should the unit ever require maintenance, remove from the hazardous location before attempting to work on the unit. If the actuator is in a critical application, it is advisable to have a standby unit in stock.
XI. TROUBLESHOOTING
SYMPTOM
Actuator does not respond to control signal
PROBLEM
• Power is not on
• Actuator wired incorrectly
• Incorrect voltage
• Thermal Overload
• Actuator and Valve in opposite positions when actuator installed
SOLUTION
• Turn on Power
• Check wiring diagram; re-wire
• Bring correct supply to actuator
• Allow motor to cool; resets automatically
• Remove actuator; remount after 90° turn
Actuator will not open and/or close completely Valve oscillates
Actuator motor
• Travel limit switch set incorrectly
• Valve torque too high
• Mechanical stops not removed when installing actuator
• Torque of valve too high
• Actuator without brake installed on butterfly valve
• Motor brake misadjusted
• Gear damaged/sheared pin
• Set cams per instructions
• Install correct unit
• Remove stops
• Torque of valve too high
• Install brake
• Adjust brake; tighten screw
• Contact factory
runs but output shaft does not rotate
®
Darina
is a registered trademark of Shell Oil Company
NEUMATIC ACTUATOR
P
ote: For optimal operation, PBV actuators should be run with a supply of clean,
N
ubricated air.
l
PRING RETURN ACTUATORS
S
ir to PORT 2 (the right hand port) causes the actuator to turn CCW. Loss of air to
A PORT 2 causes air to exhaust and the actuator turns CW. This is the FAIL CLOSE operation.
DOUBLE ACTING ACTUATORS
ir to PORT 2 (the right hand port) causes the actuator to turn CCW. Air to PORT
A
(the left hand port) causes the actuator to turn CW.
1
ISASSEMBLING STANDARD ACTUATORS
D IMPORTANT: Before beginning disassembly, ensure that the air supply to the
actuator has been disconnected, all accessories have been removed and that the actuator has been dismounted from the valve.
. Loosen the end cap fasteners (22) with a wrench (size varies depending on
1
ctuator model). On the spring return actuator, alternate 3 to 5 turns on each
a
astener until the springs are completely decompressed. Use caution in
f removing the cap since the springs are under load until the fasteners are fully extended.
2. Remove the pinion snap ring (10) with a lock ring tool. The indicator (7) may now be removed.
. Turn the pinion shaft (2) CCW until the pistons are at the full end of travel.
3
isengage the pistons (11) from the pinion. (NOTE: Low pressure air--3 to 5
D
.S.I. MAXIMUM--might be required to force the pistons completely from the
P body.) Note the position of the pistons before removing them from the actuator
ody. The part numbers of the pistons are located on the side and should be
b
ight-side up on an actuator with a standard orientation.
r
. Remove the pinion through the bottom of the actuator. The actuator is now
4
completely disassembled. All replacement parts may now be put in. W.E. Anderson recommends that all wear parts (3, 4, 5, 6, 12, 13, 14) be replaced before reassembly.
REASSEMBLING STANDARD ACTUATORS IMPORTANT: Be sure that the actuator surfaces are free of grit and scratches before reassembling.
1. Apply a light film of grease to all o-rings and the pinion before replacing.
2. Put the pinion (2) back through the actuator with the flats of the pinion shaft running parallel with the body.
3. When reassembling the actuator, make sure that the piston racks are square to the actuator body and returned to their original orientation. (NOTE: The normal operation of all PBV pneumatic actuators is FAIL CLOSED. To change the orientation to FAIL OPEN, rotate the racks 180º to create a reverse operation.)
4. When replacing springs in a spring return actuator, ensure that the springs are replaced in their identical position in the end cap from which they were removed. (NOTE: In some circumstances, you might want to change the standard 80 pound spring set to fit your application and available air pressure. Changing the spring sets on PBV pneumatic actuators requires no special tools. Please refer to the spring combination torque chart in our catalog for the inner and outer spring combinations that will allow you to operate with the spring set that you desire.)
4. Seal the end caps with a petroleum lubricant and bolt to actuator body.
5. Check the seal of the actuator by covering seal areas (pinion, end caps) with soapy water and using low pressure air to the actuator to ensure that no bubbles are produced.
NEUMATIC ACTUATOR PARTS LIST
P
1. Extruded aluminum housing
2. Nickel plated steel anti-blowout pinion
3. NBR 70 lower pinion O-ring
4. PTFE pinion spacer ring
5. NBR 70 top pinion O-ring
6. PTFE cam spacer ring . SS indicator cam
7
. Nylon position indicator
8
. SS pinion washer
9
10. Pinion snap ring
11. Die cast aluminum piston
12. Piston O-ring bushing
13. PTFE antifriction ring
14. PTFE piston thrust block
15. SS stop bolt retaining nut
16. SS stop bolt
17. External spring*
8. Internal spring*
1
9. Die cast aluminum end cap (left)
1
0. Die cast aluminum end cap (right)
2
21. NBR end cap seats
22. SS end cap bolt
*spring return actuators only parts subject to wear. Please contact the factory or your W.E. Anderson distributor for replacement kits.
MAINTENANCE
The Series PBV Automated Ball Valves are not field serviceable and should be returned if repair is needed (field repair should not be attempted and may void warranty). Be sure to include a brief description of the problem plus any relevant application notes. Contact customer service to receive a return goods authorization number before shipping.
©Copyright 2012 Dwyer Instruments, Inc. Printed in U.S.A. 8/12 FR# R2-443424-00 Rev. 1
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com