Specifications - Installation and Operating Instructions
Bulletin G-64
Series DPMA-5 Adjustable Panel Meter offers a large 1˝, 3-1/2 digit
display for easy viewing in a standard 1/8 DIN package. Unit accepts
voltage inputs with a wide bipolar span and zero adjustment. Standard
features include field selectable engineering units and decimal point
positions. Choose from red, amber, or green segments for easy viewing
at a distance. A separate 24 VDC power supply is required for the
operation of the backlight.
INSTALLATION
The Series DPMA-5 is designed to snap into a 3.62˝ (92 mm) W x 1.77˝
(45 mm) H panel cutout. No additional hardware is required.
WIRING
Figure 1
Three sets of jumper pins are located on the back of the meter. Move
the jumper to fit over the appropriate pins which correspond to the
desired signal input voltage, supply voltage and decimal point position.
An external 12 or 24 VDC power supply is required to power the meter
and should be connected to the screw terminal marked with “+pwr-” (see
Figure 2). The backlighting requires a separate 24 VDC power supply
and should be connected to terminals identified with “+B/L-”.
SPECIFICATIONS
Input: 0 to 200 mVDC, 0 to 5 VDC, or 0 to 10 VDC.
Input Impedence: 390KΩ nominal.
Accuracy: ±(0.05% FS + 1 count).
Power Supply: 12 VDC or 24 VDC.
Backlight Power Supply: 24 VDC @ 35 mA typical.
Span and Zero: Adjustable. (±1999 counts).
Display: 3-1/2 digits, 7 segments, 1˝ (25.4 mm) H.
Decimal Points: 3-position, user selectable.
Engineering Units: DPMA-XXX: °F, °C, %, PSI; DPMA-XXXP: V, A,
KW, PF.
Polarity: Automatic, “-” displayed.
Operating Temperature: 32 to 122°F (0 to 50°C).
Storage Temperature: -4 to 158°F (-20 to 70°C).
Mounting: Snap-in panel mount or clamp (gasket included).
Connection: Screw terminals.
Conversion Rate: 3 per second.
Warm-up: 10 minutes typical.
Weight: 4 oz (113.4 g).
Agency Approvals: RoHS.
Figure 2
The unit accepts 200 mVDC, 5 VDC, or 10 VDC. Wire the input signal to
terminal “+sig-” and put a jumper between “-sig” and “-pwr” (see Figure
3).
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
Figure 3
Phone: 219/879-8000 www.dwyer-inst.com
OPERATION
%
P
SI
P
Models
P
F
K
W
P Models
V
A
°
F
°
C
(
13 PIN HEADER)
Selecting Engineering Units
Four sets of jumper pins are located in the back of the meter, between the
meter and the adder board. Move the jumper to fit over the appropriate
pins which correspond to the desired engineering units. See Figure 1
Example shows °C turned on.
Figure 4
Selecting Decimal Point Position
Four decimal point positions are available on the digital panel meter. Move
the jumper to correspond to the desired decimal point location. See Figure
5.
MAINTENANCE/REPAIR
Upon final installation of the Series DPMA-5, no routine maintenance is
required. The Series DPMA-5 is not field serviceable and should be
returned if repair is needed. Field repair should not be attempted and may
void warranty.
WARRANTY/RETURN
Refer to “Terms and Conditions of Sale” in our catalog and on our website.
Contact customer service to receive a Return Goods Authorization number
before shipping the product back for repair. Be sure to include a brief
description of the problem plus any additional application notes.
Figure 5
©Copyright 2013 Dwyer Instruments, Inc. Printed in U.S.A. 8/13 FR#R5-443474-10 Rev. 2
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
Phone: 219/879-8000 www.dwyer-inst.com