Series DPGAB & DPGWB Digital Pressure Gages
O
N
O
FF
Z
ERO
U
NITS
3-3/32
[78.58]
3-59/64
[
99.62]
1
-25/32
[45.24]
1/4 NPT
Specifications - Installation and Operating Instructions
PGWB DPGAB
D
Bulletin A-34D
The Series DPGAB & DPGWB Digital Pressure Gages have
a precise ±0.5% full scale accuracy. The 4 digit digital display
will reduce the potential for errors in readings by eliminating
parallax error commonly produced with analog gages.
The DPGAB & DPGWB are packaged in an ABS plastic case.
The unit is battery powered and has an auto-shut off to conserve
battery life. A two button key pad allows easy access to features
without the need to work through complex menus. These
features include, auto zero and conversion of the pressure units.
Readings may be converted to various engineering units. See
reverse page for available units.
OPERATING INSTRUCTIONS
For complete instructions on the two button operation see the
flow chart provided on back.
On/Off: Press ON/OFF to toggle on and off. Device will
automatically shut off after 20 minutes if not used.
Zero: Zeros the display - Push & hold for 2 seconds to zero the
display. If after pressing zero the display does not re-zero, the
unit is no longer meeting specified accuracy and should be sent
back to the factory for calibration. Do not use the zero button
when pressure is applied.
Units: To change units, press both On/Off and Zero buttons
simultaneously.
Overpressure Indicator: The LCD will flash “OFL”, if the
pressure applied is over 105% F.S.
SPECIFICATIONS
Service: DPGAB: Air and compatible gases; DPGWB: Liquids
and compatible gases.
Wetted Materials:
DPGAB: 316L SS, silicone sensor;
DPGWB: Type 316L SS.
Housing Materials: ABS plastic.
Accuracy: ±0.5% F.S. (Includes linearity, hysteresis,
repeatability).
Pressure Limits: 2X pressure range. Vacuum range max.
pressure is 30 psig.
Temperature Limits: 30 to 120°F (-1 to 49°C).
Thermal Effect: 0.05% FS/°F.
Size: 2.62˝ O.D. x 1.52˝ deep.
Process Connections: 1/4˝ male NPT.
Display: 4-digit LCD (.425˝ H x .234˝ W digits).
Power Requirements: 9 volt alkaline battery. Battery included
but not connected.
Auto Shut-off: 20 minute auto shut-off.
Weight: 5.6 oz (160 g).
INSTALLATION
When installing gage always use 1˝ hex at the base of the
housing to tighten the gage to a mating fitting. Do not apply
wrench to housing.
MAINTENANCE
Battery Removal: Remove the screw on backplate. Lift
backplate off by hand. To reassemble replace backplate and
screw.
Replace batteries per polarity indicators.
A “LOW BAT” descriptor indication will appear on the display
when batteries need to be replaced.
DWYER INSTRUMENTS, INC.
P.O. Box 373 • Michigan City, IN 46360, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
Phone: 219/879-8000 www.dwyer-inst.com
DPGAB & DPGWB BUTTON OPERATION
To Turn On & Off:
Press to turn unit on.
Press again to turn unit off.
To Zero Display:
To zero display, disconnect gage from any pressure source. Press and hold zero button until the LCD displays
- - -”, then release.
“
To Change Units:
To change units, disconnect gage from any pressure source. Press both & buttons simultaneously
until desired units are displayed.
Model
DPGAB-00
DPGAB-01
DPGAB-02
DPGAB-03
DPGAB-04
DPGAB-05
DPGAB-06
DPGAB-07
DPGAB-08
DPGAB-09
DPGAB-10
DPGAB-11
Model
DPGWB-00
DPGWB-04
DPGWB-05
DPGWB-06
DPGWB-07
DPGWB-08
DPGWB-09
DPGWB-10
DPGWB-11
Range
30˝ Hg to 0 (vac)
0 to 20˝ w.c.
0 to 1 psi
0 to 2 psi
0 to 5 psi
0 to 15 psi
0 to 30 psi
0 to 50 psi
0 to 100 psi
0 to 200 psi
0 to 300 psi
0 to 500 psi
Range
30˝ Hg to 0 (vac)
0 to 5 psi
0 to 15 psi
0 to 30 psi
0 to 50 psi
0 to 100 psi
0 to 200 psi
0 to 300 psi
0 to 500 psi
psi
-14.70
0.722
1.000
2.000
5.000
15.00
30.00
50.00
100.0
200.0
300.0
500.0
psi
-14.70
5.000
15.00
30.00
50.00
100.0
200.0
300.0
500.0
kg/cm
-1.033
.0508
.0703
.1406
.3515
1.055
2.109
3.515
7.03
14.06
21.09
35.15
kg/cm
-1.033
.3515
1.055
2.109
3.515
7.03
14.06
21.09
35.15
2
2
bar
-1.013
.0498
.0689
.1379
.3447
1.034
2.068
3.447
6.89
13.79
20.68
34.47
bar
-1.013
.3447
1.034
2.068
3.447
6.89
13.79
20.68
34.47
in Hg
-29.93
1.471
2.036
4.072
10.18
30.54
61.1
101.8
203.6
407.2
611
1018
in Hg
-29.93
10.18
30.54
61.1
101.8
203.6
407.2
611
1018
ft wc
-33.94
1.667
2.307
4.614
11.53
34.60
69.2
115.3
230.7
461.3
692
1153
ft wc
-33.94
11.53
34.60
69.2
115.3
230.7
461.3
692
1153
Pressure Ranges
kPa
oz/in
-235.2
-101.4
11.55
4.980
16.00
6.89
32.00
13.79
80.0
34.47
240.0
103.4
480.0
206.8
800
344.7
1600
689
3200
1379
4800
2068
3447
Pressure Ranges
kPa
oz/in
-235.2
-101.4
80.0
34.47
240.0
103.4
480.0
206.8
800
344.7
1600
689
3200
1379
4800
2068
3447
2
2
in wc
-407.3
20.00
27.68
55.4
138.4
415.2
830
1384
2768
in wc
-407.3
138.4
415.2
830
1384
2768
mbar
-1013
49.80
68.9
137.9
344.7
1034
2068
3447
mbar
-1013
344.7
1034
2068
3447
cm wc
-1034
50.8
70.3
140.6
351.5
1055
2109
3515
cm wc
-1034
351.5
1055
2109
3515
mm Hg
-761
37.37
51.7
103.4
258.6
776
1551
2586
mm Hg
-761
258.6
776
1551
2586
Resolution
psi
0.01
0.001
0.001
0.001
0.002
0.01
0.01
0.02
0.1
0.1
0.1
0.2
Resolution
psi
0.01
0.002
0.01
0.01
0.02
0.1
0.1
0.1
0.2
©Copyright 2013 Dwyer Instruments, Inc. Printed in U.S.A. 5/13 FR# 18-443798-00 Rev.1
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. Box 373 • Michigan City, IN 46360, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com