Dwyer CD User Manual

Bulletin IN-619
COMMON
ON HIGH
ON LOW
Series CS Low Cost Diaphragm Pressure Switches
Specifications – Installation and Operating Instructions
1-5/16
[33.34]
The Series CS Low Cost Diaphragm Pressure Switch is ideal for instrument panels, small compressors and gen­eral industrial applications. Visible set point and easy-to­wire SPDT snap switch reduce installation time. This switch operates in any position and is vibration resistant.
INSTALLATION/MOUNTING
The control can be pipe mounted. Do not twist the case when installing. Use wrench on the pressure connection flats.
WIRING
All wiring must conform to the National Electrical code and local regulations. Do not install control to handle loads in excess of electrical rating shown in specifications or as indicated on instructions inside control cover. Connect wiring to screw terminals depending on the action required. Common and High contacts will close and Common and Low contacts will open when increas­ing pressure (or vacuum) reaches set point. The reverse will occur when pressure (or vacuum) drops below the set point less the deadband.
WIRING DIAGRAM
TOP VIEW
CAUTIONS: Do not oil any parts. Mount control securely. Never exceed electrical rating for switch. Use only with compatible.
11/16
[17.46]
1-1/16
[26.99]
1/2 [12.7] CONDUIT HOLE
3
[76.2]
3-3/4
[95.25]
3-3/16 [80.96]
1/4 NPT
2-3/16
[55.56]
PHYSICAL DATA Temperature Limits: -30 to 150°F (-34.4 to 65.6°C) Pressure Connections: 1/4″ NPT(F) Electrical Ratings: 12 A @ 120 VAC; 8 A @ 240 VAC; 7A
@ 277 VAC; 1/8 HP @ 120 VAC; 1/4HP @ 240 VAC
Switch Type: SPDT snap acting Conduit Opening:1/2″ Wiring Connections: Three screw type, common, N.O.,
N.C.
Set Point Adjustment: Screw type, inside cover Housing: Galvanized steel, NEMA 1 Diaphragm: Buna-N/Nylon Calibration Spring: Plated steel Installation: Any position Weight:1/2lb. (0.23 kg)
Model
No.
CS-1
CS-3
CS-10
CS-30
CS-150
Adjustable
Operating Range
1-30" Hg. Vac.
2.5-75 cm Hg.Vac 10-100" w.c.
2.5-250 cm w.c. 1-10 psig
0.07-0.7 kg/cm 1-30 psig
0.07-2.1 kg/cm 10-150 psig
0.07-10.5 kg/cm
2
2
Fixed Deadband
Maximum Minimum
1.5" Hg.
3.8 cm Hg. Vac 7" w.c.
17.8 cm w.c.
0.4 psig
1.0 psig
5 psig
2
2
2
2
0.03 kg/cm
0.07 kg/cm
0.35 kg/cm
1" Hg. VAC
2.5 cm Hg. Vac 5" w.c.
12.7 cm w.c.
0.25 psig
0.02 kg/cm
0.5 psig
0.035 kg/cm
1.5 psig
0.1 kg/cm
2
Max.
Pressure
30 psig 30 psig
2
30 psig 50 psig
2
175 psig
WARNING
A failure resulting in injury or damage can be caused by over-pressure, excessive vibration or pressure pulsation, excessive temperature, corrosion of pressure containing parts and movement assembly, electrical overload or other misuse.
©Copyright 2001 Dwyer Instruments, Inc. Printed in U.S.A. 4/01 FR#90-442119-00 Rev. 2
MERCOID DIVISION
DWYER INSTRUMENTS, INC. P.O. BOX 258 • MICHIGAN CITY, INDIANA 46361 U.S.A.
Phone: 219/879-8000 www.dwyer-inst.com Fax: 219/872-9057 e-mail: info@dwyer-inst.com Lit-by-Fax: 888/891-4963