Dwyer BTM3 User Manual

Bulletin T-14
Series BTM3 Maximum/Minimum Bimetal Thermometer
Specifications - Installation and Operating Instructions
STEM LENGTH
1/2 NPT
DIAL SIZE
13/16
[20.64 ]
1
[25.4]
The Series BTM3 Maximum/Minimum Bimetal Thermometer
accurately measures the current temperature along with the maximum or minimum temperatures. The adjustment knob is used to reset the minimum or maximum temperature to the cur­rent reading. Series BTM3 thermometers are conveniently available in multiple temperature ranges and stem lengths rang­ing from 2-1/2 to 12 inches. These heavy duty back-connected thermometers are ideal for any industrial application such as boilers, ovens, or refrigerated cabinets.
Ø3-9/32
[Ø83.34]
SPECIFICATIONS Wetted Materials: 304 SS. Lens: Scratch resistant glass. Accuracy: ±1%. Ambient Operating Temperature: 15 to 300˚F (-10 to 150˚C). Dial Size: 3˝. Connection: 1/2˝ NPT. Resolution: 2°. Weight: 7.4 oz (210 g).
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
AMBIENT TEMPERATURE ADJUSTMENT
(All reset adjustments must be done using an adequately agitat­ed temperature bath operating at a known temperature. Instruments used to monitor such a bath require a greater accu­racy than the thermometer being adjusted.)
The Series BTM3 is equipped with an external reset adjust­ment. To make an adjustment, use a flathead screwdriver or a small wrench to turn the slotted hexagonal adjustment on the back of the case. Do this until the temperature pointer reads the appropriate temperature on the dial.
OPERATION
To obtain a minimum or maximum temperature reading on the Series BTM3, simply turn the knob on the center of the dial in the indicated direction to move the red pointer to the current temperature (black pointer). If the red pointer is above the black pointer, the red pointer displays the maximum temperature. If the red pointer is below the black pointer, the red pointer dis­plays the minimum temperature.
©Copyright 2009 Dwyer Instruments, Inc. Printed in U.S.A. 3/09 FR# R7-443612-00 Rev. 1
MAINTENANCE
Upon final installation of the Series BTM3 Bimetal Thermometer with Maximum/Minimum Temperature Pointer, no routine main­tenance is required. A periodic check of the system calibration is recommended. The Series BTM3 is not field serviceable and should be returned if repair is needed (field repair should not be attempted and may void warranty). Be sure to include a brief description of the problem plus any relevant application notes. Contact customer service to receive a return goods authoriza­tion number before shipping.
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com