Duro-Last Stack Flashing User Manual

DURO-LAST® STACK FLASHING
Duro-Last® Stack Flashings are required for all round penetrations encountered on a roofing project. The stack flashings are made with Duro-Last specially
formulated roofing membrane. The combination of reinforced membrane and prefabrication ensures a long lasting, watertight flashing.
Stack flashings are available in white, tan, gray and dark gray colors. They can also be ordered with Designer Series membrane (slate gray Shingle-Ply, sandstone Shingle-Ply or Rock-Ply) bases an d solid color risers. They are available in diameters of 1 in. (25 mm), 1.5 in. (38 mm) and in 1 in. increments between 2 and 15 in. (51-381 mm). Stack Flashings
with diameters of 16 in. (406 mm) and larger are available in 2 in. (51 mm) increments.
The flashings are manufactured o versized to account
for the thickness a schedule 40 pipe wall by the
following amounts:
1.5 - 4 in. (38 - 101 mm) diameter stack flashings
are 5/8 in. (15 mm) oversized.
All other sizes are 3/8 in. (9 mm) oversized.
Installation:
1. The roof membrane installed around the
penetration must be fastened prior to i nstalling the stack flashing. Use the same fastener spacing that was used to inst all the roof membrane but do not exceed 18 in. (457 mm) on center. At least one fastener must be installed. On reroofing applications, remove the existing flashings to ensure a watertight fit.
2. Place the stack flashing around the penetration.
Heat weld the vertical seam if the stack was ordered “open”.
3. Weld the stack flashing skirt to the roof membrane.
Care should be taken to smooth out the skirt so that it is wrinkle-free.
4. Apply a bead of Duro-Caulk Plus® to the penetration 1/4 in. (6 mm) below the top of the stack flashing.
5. Install a s tainless steel band a pproximately 1/4 in. (6 mm) from the top of the stack flashing. Tighten the band to draw the flashing firmly into the sealant. Apply a bead of the Duro-Caulk Plus® around the top of the flashing to assure a positive seal.
www.duro-last.com
"Duro-Last " an d " The World's Best Roof" are registered marks owned by Duro-Las t , Inc.
CLOSED
6. See details 4070, 4080 and 4081 for i nformation on installing stack flashings to s pecific types of round penetrations.
Note:
Stack flashings and bands shall be furnished by
Duro-Last, Inc.
Field fabric ation of flashings for round penetrations
is not allowed.
Stack flashings with diame ters 16 in. (406 mm) and
larger are available "open" only.
An "open" stack flashing requires a heat weld
(hot-air) to close the flashing. The extra material necessary for this weld is included as part of the stack flashing.
Diameter
1 in.
(25 mm)
1.5 in.
(38 mm)
2 - 8 in.
(51 - 203 mm)
9 - 15 in.
(228 - 381 mm)
16 in.
(406 mm)
and Larger
Duro-Last: The Proven Performer®
11
DATA SHEET
OPEN
Stack Flashing Dimensions
Available
Height
Open
Closed
Yes No
Yes Yes
Yes Yes
Yes Yes
No Yes
8 in.
(203 mm)
8 in.
(203 mm)
8 in.
(203 mm)
8 in.
(203 mm)
8 in.
(203 mm)
800-248-0280
Base/Skirt
18 x 18 in. Base
(457 x 457 mm)
18 x 18 in. Base
(457 x 457 mm)
18 x 18 in. Base
(457 x 457 mm)
24 x 24 in. Base
(609 x 609 mm)
6 or 12 in. Skirt
(152 or 305 mm )